Pulse Oximeter Portable Monitoring Device for Smart Bracelet

Purchase Qty. / FOB Price:

Get Latest Price
US$ 50.00-99.00 / Piece Min. Order: 1 Piece
100PCS/Day

Quick Details

BM2000D
OLED Screen
Plastic
Blue
Aged, Adult, Child
3.0 and 4.0
PC, Android, Ios
with 10 Years Manufacturer
Excellent Engineers and Technicians
Lithium Battery
50g
60*58*20mm
Berry
Cartoon
CE
Shanghai
9018199000
View All
Shanghai Berry Electronic Tech Co., Ltd.

Member Since: 2014

Business Type:

Shanghai, China

You Might Also Like

Customers Also Viewed

Related Videos

Failed to load data.

Product Details


BM2000D Sleep monitoring system
Suitable for sleep hypopnea syndrome monitoring

Instructions
Berry Sleep Apnea Screening Monitor has CE0123, ISO13485, NMPA and we can meet most people's measurements of blood oxygen and pulse rate. It can accurately capture pulse signals and has been validated in numerous clinical trials.
 

Widely Used In Daily Life
BM2000D applies to Aviation,Snorer,Child,Asthma,COPD

Major Features
1.Watch type, light weight.
2.Simple and convenient, get all function with one touch button.
3.Color OLED display of SpO2, Pulse Rate, Pulse intensity bargraph, and Plethysmogram, indication of battery, Bluetooth.
4.Low power consumption, built-in 3.7v rechargeable lithium battery lasting 24 hours.
5.Automatically screen off after 30s, automatic shutdown after 10 mimutes when probe off or no finger in testing, No manually shutdown.
6.High accuracy under the condition of low perfusion.


Operation Process
1,Download the BerrySmartHealth APP from Google Play and Apple Store.
2,Wear the equipment to keep at least 6 hours sleep monitoring.
3,Put on the device and wrap foam spO2 sensor around fingertip.
4,The collected data is transferred to the mobile phone via bluetooth.
5,Display report on phone.
6,Reports can be shared.


Technical Features

Display SpO2, PR
Battery Type: 3.7v (600mAh) Lithium battery
Pulse Rate:
Measurement range: 25 - 250bpm
Accuracy: ±2bpm
SpO2:
Measurement range: 0% - 100%
Accuracy: ±2% (70% - 100%)
Size:55(L)x37(W)x18(D)mm
Weight: 52g±1g (Do not contain sensor)
Working Voltage: DC 3.4v ~ DC 4.3v
Free App: "BerrySmartHealth"

Accuracy Test

Blood Oxygen Concentration Tes                                                                     Pulse Rate Test               

                                                                                                            Berry Product Rate VS Reference heart rate ECG
                                                                                                            Correlation=0.98, P-value< 0.0001
                              Average reference oximeter                                                                       Reference Heart Rate(ECG)                           

                                            Effective (SaO2)                                                                                       (ECG) [BPM]

Comparison: Reference Pulse Oximeter
Berry Pulse Oximeter
70 ~ 100
90 ~ 100
80 - < 90
67 - < 80
RESE≤3% Within the range of 70~100%
# pts
240
79
81
81
Error
-0.6
-1.1
-0.9
0.1

Pass
Root mean square error
1.9
1.7
2.0
2.1
 
Berry products have passed the accuracy test, blood oxygen
concentration accuracy <2%,510k requirements<3%

 

Parameter Comparison Chart
Apnea Trend
Hypopnea Trend

Software Advantage
 
Blood Oxygen Results                                        Mean Blood Oxygen Results
 
 
    Diagnosis Of Hypoxemia                                              OSAHS Diagnosis         
 
PSG vs. ROC Curve

 

Analysis Of Clinical Trial Results

Mean Blood Oxygen
Average blood oxygen calculation accuracy: 98.51%
Diagnosis of hypoxemia
Sensitivity: 89.29%
Specificity: 77.78%
Accuracy:92.59%
OSAHS Judgment Results
Sensitivity: 94.17%
Specificity: 61.21%
Accuracy:89.62%

 

Standard Configuration
1,Foam SpO2 Sensor
2,Charging Cable 
3,Gift Box
4,User Manual
Reports can be shared.

 

Physical Identity
Dimension: 55(L) × 37(W) × 18(D) mm
Weight: 52g±1g (Do not contain sensor)

 

 

View More