Working principle
Feeding specification: 0-50KG/pack
Feeding method: single feeding port/double feeding port
Material lifting: manual/lifting bucket/lifting truck/forklift
Arch breaking type: pneumatic high-frequency vibration/activation hopper vibration
Blowback type: pneumatic pulse
Optional equipment: iron remover/single-layer vibrating screen/coarse crusher/bagging device/weighing and conveying
Technical Parameter
Model
RX-WT100
RX-WT150
RX-WT200
RX-WT300
Volume(L)
100
150
200
300
Power(KW)
0.8
2
2
2
Noise(dB)
70
80
80
80
0.6MPaCompressed air consumption(L/min)
5
5
5
5
Discharge interface
DN150
DN200
DN200
DN250
Dust removal fan exhaust interface
φ100
φ100
φ100
φ100
Weight(Kg)
About170
About 200
About 220
About 240
Overall dimensions
(mm L×W×H)
800*900*1800
900*1000*2200
1150*1300*2000
850*1100*2600
Rated parameters of power supply
380V/50Hz,Three phase five wire power supply
Short circuit rated current SCCR(KA)
6
Other power source parameters
The feeding station requires the use of dry and clean compressed air,Pressure≤0.6MPa.Required pressure dew point-20ºC,Dust content 5.0mg/m³(Particle size 5μm),oil content 1.0mg/m³
Product configuration
Customer referenc
Product Features
Product characteristics of dust-free feeding station:
1. Simple structure, safe and convenient operation, and convenient maintenance;
2. Dust free operation, achieving fully enclosed bag feeding and pipeline transportation;
3. No dead corner design, easy to clean;
4. Automatic dust removal system, eliminating dust flying and improving the working environment;
5. Various specifications of bag opening stations can meet different processing requirements;
6. Suitable for industries involving powders such as pharmaceuticals, food, chemicals, batteries, etc.
Common troubleshooting
When there is a malfunction in the dust-free feeding station, please check according to the following procedure first:
Fault phenomenon
Fault cause
Troubleshooting
No backflushing
The compressed air valve is not open
Open the compressed air valve
Pulse valve malfunction
Check pulse valve
Filter clogged
Replacing the filter element
No electric vibration
Damaged vibration motor
Replace the vibration motor
The vibration motor is not powered on
Connect the power supply to the vibration motor
Slow or no fan extraction
Fan damage
Replacing the fan
Filter clogged
Replacing the filter element
If the fault cannot be eliminated after following the processing methods listed in the above table. Please contact our sales personnel in a timely manner so that we can quickly diagnose the cause and troubleshoot the problem for you.
Application Industry
Dust free feeding station
Product application scope: food industry, pharmaceutical industry, metallurgy and mining industry, chemical industry
Materials: essence, monosodium glutamate, adsorbent, catalyst, graphite, rouge, powder blusher, polyethylene, polypropylene, polyoxyethylene, fertilizer, veterinary medicine, feed, premix, additives, laundry powder, salt, monosodium glutamate, chicken essence, white sugar, seeds.