93HD-10~80K 33 Industrial UPS Specifications
Capacity
384Vdc
Rated capacity
10kVA
15kVA
20kVA
30kVA
40kVA
50kVA
60kVA
80kVA
Active power
9kW
13.5kW
18kW
27kW
36kW
45kW
54kW
72kW
Mains
Rectifier topology
6 or 12 pulses
Mains input and bypass input
Dual input
Input type
Three-phase + PE
Rated AC input
380/400/415VAC
Voltage range
285VAC ~ 498VAC
Rated frequency
50/60Hz
Frequency range
45-66Hz
Bypass
Rated AC input
380/400/415VAC (three-phase + neutral)
Voltage range
-40% ~ +20% adjustable
Frequency range
50/60Hz (± 2.5%, ±5%, ±10%, ±20% adjustable)
Output
Rated AC output
380/400/415VAC (three-phase + neutral)
Voltage tolerance (Static)
±1%
Power factor
0.9
Voltage tolerance (Dynamic)
±5% (variable within 0~100% load)
THDv
< 1%(100% linear load)
Voltage dynamic response
< 20ms
Synchronization range
±2 Hz by default ( ±0.5~ ± 3Hz adjustable)
Inverter overload capacity
Continuous operating at 110% load;
10-min operating at 125% load;
1-min operating at 150% load;
Frequency stability
±0.05%
Waveform
Pure sine wave
Efficiency
Double-conversion mode
Up to 92%
ECO mode
Up to 96%
Parallel system
Parallel Unit
Up to 8
Battery
configuration
Battery quantity
VRLA battery: 30 - 32 blocks
Dimension
Depth (mm)
720
750
Height (mm)
1100
1400
Width (mm)
6-pulse
560
800
12-pulse
970
1270
Environmental
and general
parameters
Display interface
7-inch touch panel with LED indicator
Communication interface
Modbus RS232/RS485 standard; Eaton industrial network card INDGW-M2 optional
Standard protection level
IP20, Up to IP42 optional
Temperature
0 ~ 40ºC
Humidity
0 ~ 95% (non-condensing)
Noise
≤57dB
≤60dB
≤63dB
Compliance
Safety
IEC60950-1,IEC62040-1-1
Electromagnetic compatibility
IEC62040-2,IEC62040-3
Certification
CE/YDT1095-2018
93HD-10~200K 33 Industrial UPS Specifications
Capacity
384Vdc
Rated capacity
100kVA
120kVA
160kVA
200kVA
Active power
90kW
108kW
144kW
180kW
Mains
Rectifier topology
6 or 12 pulses
Mains input and bypass input
Dual input
Input type
Three-phase + PE
Rated AC input
380/400/415VAC
Voltage range
285VAC ~ 498VAC
Rated frequency
50/60Hz
Frequency range
45-66Hz
Bypass
Rated AC input
380/400/415VAC (three-phase + neutral)
Voltage range
-40% ~ +20% adjustable
Frequency range
50/60Hz (± 2.5%,±5%,±10%,±20% adjustable)
Output
Rated AC output
380/400/415VAC (three-phase + neutral)
Voltage tolerance (Static)
±1%
Power factor
0.9
Voltage tolerance (Dynamic)
±5%(variable within 0 ~ 100% load)
THDv
< 1%(100% linear load)
Voltage dynamic response
< 20ms
Synchronization range
±2 Hz by default ( ±0.5 ~ ± 3Hz adjustable)
Inverter overload capacity
Continuous operating at 110% load;
10-min operating at 125% load;
1-min operating at 150% load;
Frequency stability
±0.05%
Waveform
Pure sine wave
Efficiency
Double-conversion mode
Up to 92%
ECO mode
Up to 96%
Parallel system
Parallel Unit
Up to 8
Battery
configuration
Battery quantity
VRLA battery: 30 - 34 blocks
Dimension
Depth (mm)
855
Height (mm)
1900
Width (mm)
6-pulse
890
1245
12-pulse
1415
1770
Environmental
and general
parameters
Display interface
7-inch touch panel with LED indicator
Communication interface
Modbus RS232/RS485 standard; Eaton industrial network card INDGW-M2 optional
Standard protection level
IP20, Up to IP42 optional
Temperature
0 ~ 40ºC
Humidity
0~95% (non-condensing)
Noise
≤67dB
≤69dB
Compliance
Safety