What is Chromatography, Spectroscopy Instrument
Chromatography, Spectroscopy Instrument is a very important category in the Instruments & Meters industry. A good Chromatography, Spectroscopy Instrument can make a big difference in your comfort and productivity. There are many styles of Chromatography, Spectroscopy Instrument available, so you can choose one that's well suited to your needs.
How to source & buy Chromatography, Spectroscopy Instrument
At made-in-china.com, Chromatography, Spectroscopy Instrument are made from various kinds of features such as Ray Type,
Gamma Ray Spectrometer,
γ-Ray Spectrometer,
X-Ray Spectrometer,
which offer unique user experiences to every kind of taste.
Take Ray Type for example, you can find Gamma Ray Spectrometer Ray Type, γ-Ray Spectrometer Ray Type and more.
By Ray Type
The Best Chromatography, Spectroscopy Instrument Products
Product Description
DW-CIC-D160 Ion Chromatograph
TECHNOLOGY INDEX
Ion Chromatographic Pump
Pressure range: 0~35 MPa
Volume of flow range: 0.001~9.999 mL/min Pressure Display accuracy: ≤0.1 Mpa
Volume of flow accuracy (setting error): RSD≤0.1%
Over pressure and leak protection: It will give an alarm and stop working in these situation.
Digita Temperature-control detection system
1. Conductivity Detector
Structure: Bipolar Conductivity Detector Detection Mode: Double conductivity detection Conductance cell size: ≤0.8μl
Output voltage: -5000~5000 mV (to regulate) Measure range: 0~100000 μS/cm (10 level to choose) Resolution : ≤0.0020 ns
Conductance cell temperature: 5~60ºC(to regulate) Constant temperature accuracy: ±0.01ºC
Baseline noise: ≤0.1%FS Baseline drift: ≤0.3%FS
2,Flow System
The whole plastic pipeline: made of PEEK materials
Six-way valve: Rheodyne electromagnetic six-way valve made in America, compression resistance of 7000 psi. Collect signals automatically.
3,Built-in low-pressure degassing device
Degree of vacuum: -70kPa Inner volume: 300ul Organic tolerance: 100%
Maximum flow rate: 10 mL / min
Degassing efficiency: degassed at 1.0mL 90% Degassing volume: 7.5 mL
4,Built-in eluent generator
Type of eluent: KOH / NaOH
Eluent concentration range: 0.1-100mM / L Concentration increment: 0.1 mM
Flow rate range: 0.1-3.0ml / min Maximum operating pressure: 20MPa
Minimum operating pressure: 5MPa
5,Analytic Capability
For high capacity anion column, pH 0~14, compatible organic solvent, etc. can be analyzed at the same time with one injection.
For high capacity cation column, lycine, ,Choline chloride can be separated and analyzed. Different types of detectors can detect several transition metallic ions, heavy metallic ions and special ions.
qualitative repeatability: ≤0.5% (Cl-, Na+ ) quantitative repeatability: ≤1.0% (Cl-, Na+) Linear range: ≥103
Minimum concentration of detection: Cl-≤0.0005 ug/ml,BrO3-≤0.001 ug/ml,Li+≤0.001 ug/ml
Detailed Photos
Certifications
FAQ