What is Alarm Host

Alarm Host is a very important category in the Security & Protection industry. A good Alarm Host can make a big difference in your comfort and productivity. There are many styles of Alarm Host available, so you can choose one that's well suited to your needs.

How to source & buy Alarm Host

At made-in-china.com, Alarm Host are made from various kinds of features such as Certification, DOT, E-MARK, CE, which offer unique user experiences to every kind of taste.
Take Certification for example, you can find DOT Certification, E-MARK Certification and more.

By Certification

The Best Alarm Host Products

16 Zones BMS Fire Evacuation Fire Alarm Host Introductions: 1. AW-CFP2166-2 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard. 2. Adopted modularized design, flexible extendable capacity. 3. Two-level control mode by a lock 4.27VDC power supply output. 5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type. 6.2 channel general sounders output. 7. Each zone has 1 circuit detectors input. 8. Each zone can be disable by a button. 9. It has RESET button to reset the panel. 10. SILENCE button to stop BUZZER and SOUNDERS. 11. EVACUATE button to start a manual fire alarm immediately. 12. TEST button to test all LEDs orderly. 13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on. 14. Optional GSM module is available for fire alarm by SMS. Asenware, professional fire alarm solution provider. ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32 Power specification Mains supply voltage 110VAC or 240VAC Internal power supply 27.2VDC Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC Main supply monitor for fault Yes Battery protection for low voltage Yes Batteries (default configuration) 12V2AH*2 Detector circuit specification Number of circuit 1 2 4-16 4-32 Line fault monitor for open circuit Yes Line fault monitor for short circuit Yes Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. Maximum number of manual call points per zone No limit Sounder circuit specification Number of general circuits 2 End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) Line fault monitor for open circuit Yes Line fault monitor for short circuit Yes Outputs fused AT 400mA Maximum number of bells @ 20mA of each sounder output 20 Fuses Battery fuse 1.5A F 20mm Sounder outputs 500mA F 20mm Fire and fault output Output type NC and NO relay Maximum current 100mA Connection block Largest acceptable conductor size 2.5mm2 Smallest acceptable conductor size 0.75mm2 Size and weight Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124 Weight (without batteries) 4kg 5kg 7kg 8kg Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
16 Zones BMS Fire Evacuation Fire Alarm Host

16 Zones BMS Fire Evacuation Fire Alarm Host

US $ 275-278/ Piece FOB
MOQ: 1 Piece
Since 2013
Contact Supplier

Related Hot Products By Alarm Host