ZMCT103U current transformer
Small size,high accuracy,good consistency,for the precise measurement of current and power
Structural parameter:
Front view Bottom View
The main technical parameter:
Model |
ZMCT103U |
primary current |
0~15A(sampling resistor 50Ω) |
secondary current |
5mA at input 5A |
turns ratio |
1000:1 |
phase angle error |
≤30'(input 5A,sampling resistor 50Ω) |
Accuracy class |
0.5 |
linearity |
≤0.2%(5%dot~120%dot) |
Permissible error |
-0.5%≤f≤+0.5%(input 5A,sampling resistor 50Ω) |
isolation voltage |
4500V |
application |
precise measurement of current and power |
Encapsulation |
Epoxy |
installation |
punching |
operating temperature |
-40ºC~+70ºC |
Direction for use:
FIGURE I FIGURE II
1. The typical usage of the product is for the active output (Figure I). R is a sampling resistor, c and r is used for phase compensation.
2. The product can be directly through the resistance sampling, easy to use (Figure II ).
3. The instructions are for reference only, specific parameter is subject to specifications (acknowledgment).