Product Description
WTZK-50-C Pressure Type Temperature Switches for VesselThe Sensor of the Switches is capillary thermometer bulb, can be apply to gas which will not exert corrosion on
Brass and Brass alloy, steam such gasous medium or liquid medium. The Set Point Adjustable range is from
-60ºC to +170ºC. WTZK-50-C, the shell material is Casting Aluminum, water-proof structure can meet the
requirements of vessel use. WTZK-50, the shell is phenolic plastic, it is the general type.
Dead Band Adjustable |
Series No. | Set Point Adjustable Range ºC | Dead Band Adjustable Range ºC | Ambient Temperature ºC | Set Point Error ±ºC | Repeatability Error ºC |
1 | -60…-30 | 3~5 | -25~55 | 4 | 2 |
2 | -40…-10 | 3ºC's higher than the controlled temperature, not lower than -25ºC, maximum to 55ºC | 2 |
3 | -25…0 |
4 | -15…+15 |
5 | 10…40 | -25~55 |
6 | 40…80 | -25 to which is 3ºC's lower than the controlled temperature, to maximum 55ºC |
7 | 60…100 | -25~55 | 3 | 3 |
8 | 80…120 |
9 | 110…150 | 5~55 |
10 | 130…170 |
The Adjustment of Set Point
The steps of how to adjust the Set Point, please refer to belows
[Example] Choose Temperature Switch of specifications -15ºCto 15ºC, it is required maintain the refrigeratory
temperature between -8ºC to -5ºC. See the steps listed below
Fix the thermometer bulb in the refrigeratory, mount the switch on the dash board outer the refrigeratory, the
capillary should be fixed steady, link the switch and power circle by leads
Rotate the Set Point Adjusting Bolt, to make the pointer stay at the calibration of -8ºC. This is the Decreasing
Set Point.
Switch should auto switch-off when interior temperature fall to -8ºC, and switch-on when temperature warm-up
to -5ºC, this is the Increasing Set Point, repeat the steps for several times to make sure.
Installation
Remove the cover, put the Switch onto the gauge instrument board vertically, Any hand or tool touch with the is
forbidden, to avoid the change of the performance.
Screw-off the Lock-nut and rotate the Set Point Adjusting Bolt, to make the pointer stay at the calibration which
is to be set, fasten the Lock-nut.
Rotate the Dead Band Adjusting Bolt, to the value of needs.
Thermometer bulb and capillary: Thermometer bulb should be immerged in the medium, the surrounding
medium should keep flow with average temperature, the capillary pipe curve radius should not smaller than
50mm. Each 300mm a clip should be used to fix the capillary on the instrument board. Series no. 1 to no. 4, the
ambient temperature for the capillary to pass through should be higher than 3ºC of the Set temperature. Series
no. 9 to no. 10, the ambient temperature should be higher than 5ºC, please avoid to flat the capillary by
machanical collision during installation.
Countercheck if the installation is steady, re-cover the enclosure, electrify the power. Regular calibrating the
Switches according to its application situation.
Cautions
What the pointer indicates is the Decreasing Set Point, the Set Point Adjustable Range just the Adjustable
Range of the Decreasing Set Point.
The figures on the Dead Band Adjusting Bolt does not REPRESENTS the actual value of the Dead Band but the
magnitude grade. The actual value should be read from the standard gauge.
When the medium which is to be controlled does not exceed a certain given pressure, the pointer should be at
the position which is smaller than the given figuer, once it is fixed, DO NOT rotate the Dead Band Adjusting Bolt.
The Dead Band Adjustable Range in the table are the minimum adjustable range which can be guaranteed, the
practical range can be wider.
Address:
Guohe Industrial Park, Menghe Town, Xinbei District, Changzhou, Jiangsu, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters
Company Introduction:
Changzhou Tianli Controller Manufacturing Co., Ltd.Is a ISO9001:2000 proved high-Tech.Enterprise.We are professional in manufacturing products includes:Pressure/Differential Transmitters, Indicating Pressure Switches, Two-level Pressure Switches, Stainless Pressure Gauges, Shakeproof Pressure Gauge, etc.We serve a countrywide market of oil and gas, chemical, petrochemical, chemical fiber, power industries, metallurgy, medical, light industry, telecommunication industries and Self-check & Control center of refregrating equipment, Self-alarm in process application and protection.Our brand "Tianxiang" is recogonized as high accuracy, High quality, reliability and varietal of specifications by the customers.
Since the company was founded in 1984, Tianli′s dedicated in producing high quality products, continually technical innovation.Our typical products could normally meets your requirements, meanwhile, we have ability in designing customized.We purse a Customer-oriented service philosophy.We make it our business to continuously improve our service and product strategies to be responsive to customer requirements.
We sincerely hope to cooperate users and friends worldwide, please feel wecome to call us or send e-mail to us.