Basic Info.
Sample Feeding
Dry Dispersion
Measuring Theory
Laser Diffraction
Measuring Range
0.1micron-2000 Micron
Dispersion Method
Compressed Air
Accuracy Error
<1%(Crm D50)
Repeatability Error
<1%(Crm D50)
Operation Mode
Digital Display
Statistic Method
Volume Distribution, Quantity Distribution
Feeding
Automatic Vibration Feeding
Transport Package
Plywood Box
Specification
L104*W44*H540cm
Product Description
Winner3008A is full automatic laser particle size analyzer with dry dispersion system. It use air as dispersion medium,and use turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It's fit for any dry powder chemical materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It's with the same accuracy and repeatability. It's first choice for lab equipment in university and research departments.
Main Specifications:
Model | Winner3008A |
Measuring Range | 0.1μm-2000μm |
Channels Number | 80 |
Accuracy error | <1% (Deviation of D50 on national standard sample) |
Repeatability error | <1% (Deviation of D50 on national standard sample ) |
Light source | He-Ne laser (λ= 632.8nm, P>2.0MW) |
Dispersion | Dry-turbulence dispersion mode |
Operation Mode | Full automatic |
Feeding | Automatic vibration feeding |
Optical Calibration System | Automatic |
Sample | Min cosumption 1g/time( related to sample) |
Test Speed | <1min for each time |
Volume | L104cm×W44cm×H54cm |
Net Weight | 58Kg |
Main Features:
1) Unique optical path
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.
2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system's working life.
3)Human-based operation mode
Manual and Full automatic, very simple and easy to learn, from sample preparation to testing report just need 1 minute.
4)High precision-automatic calibration system
It's composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.
5)Intelligent data analysis
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution
by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy
and repeatability of the output.
6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support userdefined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(greater than or less than a certain particle diameter).
7) Users can design the test report output and display forms according to industry requirements.
Application:
Winner3008A Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments,
fillers, chemical products,catalysts, coal dust, additives, pesticides, explosives, graphite, photographic
materials, fuel, metal and non-metal powder, carbonated calcium, kaolin and other powder industry,
particularly for chemical reaction occurs in the liquid, the shape change and the loss of such herbs,
magnetic materials and relatively wide distribution and larger particles powder industry more unique
applicability and practicality.
Address:
Building F, North Area, University Science Indurstry Park, Shunhua Road, High-Tech District, Jinan, Shandong, China
Business Type:
Manufacturer/Factory, Trading Company
Business Range:
Agriculture & Food, Chemicals, Industrial Equipment & Components, Instruments & Meters, Metallurgy, Mineral & Energy
Management System Certification:
ISO 9001
Company Introduction:
JINAN WINNER PARTICLE INSTRUMENT STOCK Co., Ltd. Have been specialized in laser particle size analyzer since 1985, Our General Manger, Professor Ren created 1st of laser paraticle size analyzer in Jinan University, We are specialized in Laser DiffractionParticle Size Analyzer, Wet & dry intelligent laser particle size analyzer, Dynamic Light Scattering Nanometer Particle Size Analyzer, Image Particle Size Analyzer, OnlineParticle Size Analyzer, Droplet Particle Size Analyzer and Particle Counter etc.
Creation of China 1st:
1st Circulation Wet Particle Analyzer 1984
1st Laser Diffraction Particle Size Analyzer 1987
1st Online-Particle Size Analyzer 1990
1st Portable Particle Size Analyzer 1992
1st Dry Laser Particle Size Analyzer 1998
1st Dynamic Particle Image Analyzer 2007
1st DLS Nanometer Particle Size Analyzer 2008
1st Digital Correlator Patent 2008
1st Wide Size Range Laser Particle Size Anal 2009
1st Joint-Stock Company of China Particle Size Analyzer 2014
1st Online-Particle Size Monitor 2014
WINNER 30 YEARS-China PARTICLE SIZE ANALYZER 30 YEARS:
1985 Prof. Zhongjing Ren directed a research project: The development of on-line cement particle analyzers, and that year this project was put into the list of the Seventh China′s Seventh Five-year-research-plan.
1990 The on-line cement particle analyzers passed the acceptance exam of China′s Seventh Five-year-research-plan The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies of this age′.
1993 The on-line cement particle analyzer won the gold medal at the First China′s Technology Expo.
1994 Took on a project of the Shandong province′s Eighth Five-year-research-plan which LED to JL 9200 portable laser particle size analyzer, and had it patented.
1995 JL 9200 portable laser particle size analyzer was put into the list of ′China′s most important new product′.
1996 Took on China′s Ninth Five-year-research-plan which LED to JL 9300 laser dry-particle size analyzer. This invention won the third-grade ′Award for Science & Tech. Progression in Shandong Province′.
2000 Jinan Winner Particle Technology Co. Ltd formally established.
2002 Winner laser particle size analyzer, Winner 2000, was approved by China′s Standard Material Research Center.
2003 Winner 2000 obtained the new product certificate of metrological instruments from Shandong Bureau of Quality and Technical Supervision.
2004 Winner Company obtains CMC certification.
2005 Moved to Jinan′s high and new technology industrial development zone.
2006 Approved as ′Jinan′s High and New Technology Enterprise′
2007 Obtained ISO90001: 2000 International Quality Management System Certification.
2007. Developed China′s first dynamic image particle size analyzer and passed the acceptance exam by Jinan Science Bureau. The comments were ′the pioneer of the art in China′ and ′one of the most advanced technologies in the world′.
2008 Developed CR128 digital correlator.
2009 Developed China′s first light correlation nano particle size analyzer
2008 Approved as ′China′s High and New Technology Enterprise′
2010. Now Winner is ten years old, and it became a joint stock Company.