• Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
  • Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
  • Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
  • Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
  • Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
  • Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems

Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems

After-sales Service: 24h/7D After-Sale Services
Warranty: 12 Months Warranty Period
Type: Water-Cooled
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems pictures & photos
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
US $9,500 / Set
Min. Order: 1 Set
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • FAQ
Overview

Basic Info.

Model NO.
FL-3000
Cooling Water
Purified Water
System Type
Closed System
Fans Species
Single-speed Fan
Noise Level
Low
Application Fields
Induction Furnace
Certification
ISO
Condition
New
Transport Package
Seaworthy Package
Specification
host ize: 3800 x 2200 x 2352; weight: 2620kg
Trademark
Liuxingke
Origin
China
HS Code
8418699090
Production Capacity
5000 Sets Per Year

Packaging & Delivery

Package Size
380.00cm * 220.00cm * 235.00cm
Package Gross Weight
2620.000kg

Product Description



Internal circulation closed cooling equipment:
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
Product Description

 

Water Consumption Stainless Steel Cooling Tower with Internal Circulation SystemsWater Consumption Stainless Steel Cooling Tower with Internal Circulation Systems

Closed type water cooling tower equipment:

Advantages:
1.Totally closed circulating cooling, preventing the pipeline blockage caused by sundries
2.Adopt soft water circulation cooling to prevent power supply, thyristor , capicitor, IGBT module, induction coil overheating damage caused by scale formation.
3.No need to dig water pool, small land occupation, convenient movement and low cost
4.High heat dissipation efficiency and low operation cost.

5.The closed circulating water consumption is small, which meets the requirements of environmental protection and energy saving.


Scope of application :
1.  Used for cooling power frequency, medium frequency, high frequency and IGBT power supply
2.  Used for cooling melting furnace, heat preservation furnace, and diathermy furnace
3.  Used for cooling complete induction heating equipment 
4.  Used for cooling complete set of medium and high frequency quenching equipment





Water-cooling  main engine
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems




Water cooling auxiliary engine / circulation pump

Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems

Stainless steel condenser coils   
     Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems







Technical parameters of the internal circulation closed cooling tower:
Model Cooling
Capacity
(Kcal/h)
Working
Pressure
(Mpa)
Working
Flow
(M3/h)
Inlet&Outlet
pipe dia.
(mm)
Circulation pump power
(kw)
Spray pump power
(kw)
Draught fan power
(kw)
Dimensions
L*W*H
(mm)
Weight
(kg)
FL-160 48160 0.15 12.5 DN50 2.2 1.1 0.75 2900*1000*2400 680
FL-250 75250 0.15 12.5 DN50 3 1.5 0.75 2900*1250*2400 820
FL-350 105000 0.15 25 DN65 4 1.5 0.75 2900*1250*2400 950
FL-500 150500 0.2 25 DN65 4 2.2 1.5 2800*1250*2430 1080
FL-600 180600 0.2 25 DN65 5.5 2.2 1.5 2800*1250*2430 1150
FL-750*2 228000 0.2 35 DN65 7.5 2.2 1.5 2800*1250*2730 1300
FL-1000 301000 0.2 50 DN80 7.5 2.2 3 3300*1500*2332 1520
FL-1250 352000 0.2 90 DN100 7.5 2.2 3 3300*1500*2332 1700
FL-1500 451500 0.25 100 DN100 11 4.4 3 3300*1500*2332 1980
FL-2000 602000 0.25 112 DN125 18.5 4.4 4.4 3300*2200*2352 2180
FL-2500 752500 0.25 130 DN125 18.5 4.4 4.4 3800*2200*2352 2410
FL-3000 903000 0.3 130 DN150 30 4.4 4.4 3800*2200*2352 2620
FL-4000 1204000 0.3 150 DN150 45 5.5 9 3800*2200*2552 3010
FL-5000 1505000 0.35 200 DN200 55 7.5 9 4850*2200*2552 3420
FL-6000 1806000 0.35 260 DN250 75 11 12 5850*2200*2552 4260

Schematic Diagram: water cooling tower working with medium frequency induction furnace
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems




Water Consumption Stainless Steel Cooling Tower with Internal Circulation SystemsWater Consumption Stainless Steel Cooling Tower with Internal Circulation Systems





Technical parameters of the internal circulation closed cooling tower:
2.After sale service
2.1.Quality Guarantee: 1 year. During the warranty period, provide free accessories. 
2.2. After the warranty period, provide accessories in time and guide installation and commissioning
2.3.Installation and Commissioning
2.3.1. Supplier offers 1-2 Engineers for instructing installation and commissioning , China domestic transportation cost and air tickets for go and back to Purchaser's factory will be paid by purchaser.  (10-15 days usually)  
2.3.2. Engineer salary for instructing installation/commissioning will be paid by purchaser ;
2.3.3.All destination local accommodation , meal and local transportation costs will be paid by purchaser

Water Consumption Stainless Steel Cooling Tower with Internal Circulation SystemsWater Consumption Stainless Steel Cooling Tower with Internal Circulation SystemsWater Consumption Stainless Steel Cooling Tower with Internal Circulation SystemsWater Consumption Stainless Steel Cooling Tower with Internal Circulation Systems

 

FAQ

 

Q.Are you a manufacturer or a trading company?
A.We are professional intelligent induction heating equipment manufacturer,we have our own research and development team and factory, we have mature technical experience to guarantee the quality of products and optimal price.

Q.How is your company's product after-sale service system?
A1. Length of product warranty:one year.
A2. Within one year, normal damage to equipment components will be provided free of charge, excluding vulnerable parts. 
A3.After the warranty period expires, we will provide the buyer with accessories at the most favorable price. 
A4. We will send 2 engineers to guide the installation and commissioning as well as test run until the equipment is in normal operation for production.
A5. For any questions raised by the buyer,we will respond within 48 hours
A6. We provide long-term free guidance on equipment maintenance and free training to technical workers for the buyer for one week in China.

Q.How long is the delivery time? If I want to customize the equipment, how long does it takes?
A.We can provide customized service for our coustomers. It usually takes 30-60 days depending on the specifications of the customer equipment.

Q.How to pay?
A. T/T, L/C

Q.How is the package of the goods ? Delivery methods?
A1.According to the specific conditions of the equipment, it is packed in a fumigation-free wooden box, PVC wrapping film and plastic woven cloth.
A2. Sea shipping and railway transport for whole set of the equipment as well as Express according to customer requirements, find the most suitable way.`````

Q.Do you provide other supporting tools besides medium frequency induction furnace, and what are them?
A. Yes, according to the customer requirements, we provide the following supporting tools:
a).Transformer
b) Push-out lining system
c) Loading cell system
d).Charging system for solid material
e).Deslag system
f). Emergency diesel generator

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems pictures & photos
Water Consumption Stainless Steel Cooling Tower with Internal Circulation Systems
US $9,500 / Set
Min. Order: 1 Set
Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000