• Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
  • Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
  • Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
  • Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
  • Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
  • Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Formula: Sio2
Appearance: Paper
Usage: Paper Chemicals
Color: Pink
Packing Quantity: 250PCS/Bag*20bags/Carton
PCS/Carton: 5000
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
  • Overview
  • Product Description
  • Detailed Photos
  • Installation Instructions
  • Applications
  • Certifications
  • Related products
  • What Our Partners Said
  • Packaging & Shipping
Overview

Basic Info.

Applications
Food, Medical, Electronics, Leather, etc
Transport Package
Vacuum Packs, Cartons and Pallets
Specification
250pcs/bag
Trademark
non
Origin
China
HS Code
3824999999
Production Capacity
100000PCS/Day

Product Description

Product Description


Oxygen indicator,also called acid detection agent is a color changing agent to intuitively judge the presence or absence of oxygen in a closed container (oxygen concentration is greater than 0.5%) or (oxygen concentration is less than 0.1%). Oxygen indicator can be used together with oxygen absorber to judge whether deoxidizer storage is effective. Oxygen indicators are used in anaerobic management to detect leakage in vacuum containers and the approximate range of oxygen concentration in nitrogen-filled packaging containers.
 

1- Oxygen indicator acid detection agent is mainly used to detect the presence or absence of oxygen in closed containers. When there is no oxygen (when the oxygen concentration is less than 0.1%), the oxygen indicator turns red; The oxygen indicator turns blue in the presence of oxygen (when oxygen concentration is greater than 0.5%).

2- Oxygen indicator can be used for commodity packaging, deoxidizer installation test, packaging container airtight detection.

3- Oxygen indicator acid detector discoloration time is related to oxygen concentration and ambient temperature and exposure to air time factors.

Detailed Photos

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food PackagingVacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food PackagingVacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Installation Instructions


1. After unpacking the outer bag, take out the oxygen indicator needed, and the remaining part should be deoxygenated and sealed with deoxygenation agent immediately.

2. When used with deaerator for sealing articles, deaerator, oxygen indicator and sealed articles can be sealed in the container at the same time, and the indicator is fixed in a convenient position for observation.

3. Do not take the indicator out of the inner packing bag and use it exposed.

4. Oxygen indicator acid detector should avoid storage and use under direct sunlight, oxygen indicator should be stored in low temperature without oxygen (under 10ºC to avoid light conditions).

5. Oxygen indicator can be used to indicate the presence of oxygen, but can not be used to produce gas and heat occasions.

 
Applications

Generally used with deoxidizer to detect oxygen concentration in closed containers (or packaging bags).

Characteristics and indication method: mainly used for indicating oxygen concentration in closed containers: when oxygen concentration is greater than 0.5%, the indicator is blue, less than 0.1%, the indicator is red, oxygen concentration between 0.1-0.5% is blue gray.

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food PackagingVacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging


Notes on the use of oxygen indicator

1- Please confirm whether the color of oxygen indicator is normal before use, and take out the deoxidizer in the bag first after opening the bag.

2- Oxygen indicator should be used at the site to avoid direct sunlight.

3- Oxygen indicator to avoid arbitrary bag opening.

4- The length of red oxygen indicator is related to the site temperature and exposure time, high temperature, long exposure to air, easy to failure.

5- The operation time after oxygen indicator is taken out shall not exceed 2 hours. The remaining oxygen indicator shall be re-put into deoxidizer and sealed, and be used up once again when opened and used.

6- If the one-time use is not large, it is recommended to split into several small packages after opening the bag, and add deoxidizer respectively to seal and preserve.

7-When using oxygen indicator, the indicator should be stored in a container or tray, and the operation site should be clean. Once the indicator falls out of the tray or falls to the ground, it should be picked up immediately. Do not use the indicator if you cannot confirm how long the indicator has fallen out.

8-Oxygen indicator without oil resistance, avoid contact with oily substances.

 

Preservation of oxygen indicator:

It is recommended that the storage temperature be lower than 10ºC. In high temperature in summer, it should be stored in cold storage. Please use it up within 2 months after purchase.

Certifications

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Related products
Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging
Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

 

What Our Partners Said

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Packaging & Shipping

Vacuum Packed Oxygen Absorber Oxygen Indication Detection Agent for Food Packaging

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now