• Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
  • Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
  • Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
  • Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
  • Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
  • Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

After-sales Service: Life Time Support Service
Warranty: 1 Year for Transformer Turn Ratiotester TTR Meter
Type: Transformer Turn Ratio Tester TTR Meter
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Characteristics
  • Main Test Items
  • Specifications
  • Wiring Connection
Overview

Basic Info.

Model NO.
GDBC-901
Display
Digital
Control
Manual Control
Weight
7kg
Power Source
AC220V
Product Name
Transformer Turn Ratio Tester TTR Meter
Applicable to Transformer
Connected in Y Type, D Type
Ratio Measurement Range
1-10000
Group Measurement Range
1-12
Phase Measurement Error
1 Degree
Standard
IEC76-1, IEC60044, GB/T1094
Power Supply
220V 50Hz/60Hz
Turn Ratio Resolution
0.0001
Test Voltage
0-80kv
Printing
Micro Printer
Transport Package
Wooden Case
Specification
400*350*200mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
300PCS/Month Turns Ratio Tester

Product Description

GDBC-901 Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

 

Characteristics

 

Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
* GDBC-901 Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter is designed according IEC76-1, IEC60044 and GB/T1094. 

* The test power supply is generated by the internal power amplifier of the tester, and the waveform distortion rate is less than 0.5% and is not affected by the quality of power supply.

* Automatic voltage regulation, with automatic protection functions such as transformer reverse connection, over-current, etc., to avoid damage to the instrument due to incorrect operation.

Main Test Items

 

  • The voltage ratio measurement for three or singe phase transformer .

  • Automatically measure the connection group of the transformer (three-phase, single-phase).

  • The group vector measurement for three phase transformer.

  • The polarity measurement for single phase transformer or CT/PT.

  • Detect the position of the transformer tap switch according to the measurement result of the turns ratio and the standard turns ratio setting.

  • Automatically calculate voltage ratio error.

  • CT PT ratio measurement.

  • Display the excitation current in the process of turns ratio measurement.

Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

Specifications

 

Ratio measurement range: 1-10000 (can be customized up to 40000)

Group measurement: 1-12

Phase measurement error: 1 degree

Ratio measurement error: 1-2000 ± 0.2%RDG, 2000-10000  ± 0.5%RDG

Test voltage: 0~80KV

♦ Power supply: AC 220V±10%, 50Hz/60Hz

♦ Operation condition: Ambient temperature 0-50°C; Ambient humidity < 85% RH

Size: 40*35*20CM

Net weight7kg

 

Wiring Connection


Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
1) Three phase transformer test

A,B,C are connected to the HV side terminal A,B,C of transformer and a,b,c are connected to the LV side terminal a,b,c of transformer

 

2) Single phase transformer and PT test

A,B are connected to HV side terminal of single phase transformer/PT and a,b are connected to LV side terminal of single phase transformer/PT. C and c are connected to nothing.

 

3) CT test

A,B are connected to secondary of CT and a,b are connected to primary of CT. C and c are connected to nothing.

 

GDBC-901 Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter Details:

Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter
Transformer Turn Ratio Tester Single Three Phase Potential Transformer TTR Meter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters