Type: | Respiratory Therapy Ventilator |
---|---|
Used for: | Adult |
Certificate: | CE |
Transport Package: | Wooden Case |
Specification: | 560*560*605mm /35KG 670*700*1160mm /80KG |
Origin: | China |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Application
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.
Features
l15" TFT LCD touchscreen displays the ventilation parameters, alarm information, and waveforms.
lAir compressor runs stably with low noise, creating a quiet environment for doctors and patients.
lIntegration breathing circuit design.
multiple working modes such as volume control and pressure limit.
Multiple parameters monitoring interface to show clear parameters to the operator, allowing the operator to know the patient's conditions in all aspects.
real time pressure-time, flow-time loop graphics, pressure-volume loop graphics, and high precision ETCO2, O2 concentration detection function included.
electrical PEEP control
The lBreathing valve is the disassembly and can be disinfected.
Ventilation modes: |
IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV, APRV, PRVC, BI-PAP |
Ventilator parameter ranges |
|
Tidal volume(Vt) |
0 ~ 2000mL |
Frequency (Freq) Oxygen concentration |
1bpm ~ 100 bpm 21%-100% |
I/E |
4:1~1:8 |
PEEP |
0cmH2O ~ 40 cmH2O |
Pressure Limit |
20 cmH2O ~ 100 cmH2O |
Monitored Parameters |
|
Frequency (Freq) |
0 /min ~ 100 /min |
Tidal volume(Vt) |
0 mL ~ 2500 mL |
MV Airway pressure Dynamic lung compliance testing ETCO2 Concentration |
0 L/min ~ 99 L/min 0 cmH2O ~ 100 cmH2O 1mL/cmH2O ~ 1000mL/cmH2O 0mmHg ~ 152mmHg (0%-20%) |
Oxygen concentration |
15 % ~ 100 %
|
Oscillographs display: |
|
P-T(pressure - time) |
|
F-T(flow - time) |
|
P-V loop (pressure - volume loop) |
|
V-T(volume - time ) |
|
ETCO2-T (End-tidal CO2 - time) |
|
|
|
Alarms and protection |
|
The AC power failure alarm |
Power failure or no connection |
Internal battery backup low voltage alarm |
≤11.3±0.3V |
No tidal volume |
No tidal volume within 6s |
High Minute Volume alarm Low Minute Volume alarm |
5L/min-99L/min 1L/min-30L/min |
High Airway pressure alarm Low Airway pressure alarm High oxygen concentration alarm Low oxygen concentration alarm |
20cmH2O-100cmH2O 0cmH2O-20cmH2O 19%-100% 18%-99% |
Continuous pressure alarm |
(PEEP+1.5cmH2O) over 16s |
Suffocation warning Fan error Oxygen deficit |
5-60s Show on screen Show on screen |
The maximum limited pressure |
<12.5 kPa |
Working conditions |
|
Gas source |
O2, AIR |
Pressure |
280kPa-600kPa |
Voltage |
~220V±22V |
Power frequency |
50Hz ± 1Hz |
Input power |
900VA (with air compressor) 250VA (without air compressor) |
Suppliers with verified business licenses