Basic Info.
Main Application
Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas
Application
Industrial Production
Measuring Principle
Mechanics
Measurement Object
Closed Pipeline
Certification
CE, RoHS, SGS, ISO
Power Supply
24VDC or Battery
Output Signal
4-20mA,Pulse
Connection
Flange or Screw Thread
Product Description
Liquid Turbine Flowmeter
Main Applications:
Turbine flow flowmeter adapts to measure the liquid rate and total flow rate of low viscosity, It can be widely used in the fields of Petrol,fuel ,water ,chemical industry,Metallurgy,Scientific research for measuring or control Several output and display methods can be selected.
Features:
-Hi-Accuracy 0.2%, 0.5%, 1% optional
-Wearable Tungsten carbonized shaft and bearing, can be used for medium of sully
-Erode-resistant can be used for sea water, ammonia, acetometer, etc.
-Bi-direction Measuring bi-direction flow (optional)
-Multi-output Pulse, 420mA, 5VDC, total and rate display in the field
-Power supply 5-24V DC
-Explode-proof Ex dBT4
-Diameter 4,6,10,15,25,40,50,80,100,150,200
Technical parameters:
Table 3-1
Nominal Diameter DN(mm) | Range(m3/h) | Liquid Temperature (ºC) | Nominal Pressure PN(MPa) | Ambient Temp. (ºC) | Humidity (%) | Max. Pressure Loss (MPa) |
Error 0.2%* | Error 0.5% | Error 1% |
Min. | Max. | Min. | Max. | Min. | Max. |
2* | | | | | 0.03 | 0.16 | -20 to +120 | 6.3 | -25 to +55 | ≤ 80 | 0.15 |
4* | | | | | 0.04 | 0.25 | 0.12 |
6 | | | 0.1 | 0.6 | 0.1 | 0.6 | 6.3 16 25 32* | 0.08 |
10 | | | 0.25 | 1.2 | 0.2 | 1.2 | 0.05 |
15 | 1.2 | 6 | 0.6 | 4 | 0.6 | 6 | 0.035 |
25 | 2 | 10 | 1.6 | 10 | 1 | 10 |
40 | 4 | 20 | 3 | 20 | 2 | 20 | 1.6 2.5 | 0.025 |
50 | 6 | 40 | 4 | 40 | 4 | 40 |
80 | 16 | 100 | 10 | 100 | 10 | 100 |
100 | 25 | 160 | 20 | 160 | 20 | 200 | 1.6 2.5 |
150 | 50 | 300 | 40 | 300 | 40 | 400 |
200 | 150 | 750 | 100 | 600 | 80 | 800 |
250* | 200 | 1000 | 160 | 1000 | 120 | 1200 | 1.6 |
300* | | | 260 | 1600 | 180 | 1800 |
Note: "*" means special order
Table 3-2 Model and Specification Code
Model | Specification Code | Description |
LW....................................................................................... | Turbine Flowmeter Transducer For Liquid |
| G........................................................................ |
| Y...................... |
Nominal Diameter | -2*................................................. -4*................................................. -6.................................................. -10................................................ -15................................................ -25................................................ -40................................................ -50................................................ -80................................................ -100.............................................. -150.............................................. -200.............................................. -250.............................................. -300.............................................. | 2mm(PT G3/8″) 4mm(PT G3/8″) 6mm(PT G3/8″) 10mm(PT G1/2″) 15mm(PT G1″) 25mm(PT G11/4″) 40mm(Flange) 50mm(Flange) 80mm(Flange) 100mm(Flange) 150mm(Flange) 200mm(Flange*) 250mm(Flange*) 300mm(Flange) |
Type Code | A............................ .......... B............................ .......... C............................ ....... | Accuracy 1% Accuracy 0.5% Accuracy 0.2%* |
Output Signal | P......................... ....... I.......................... ....... T......................... ....... M........................ ....... | Pulse Analog 4 to 20mA Total display(Battery. for 2 to 3 years) Pulse out/4 to 20mA out and LCD display(Intelligent) |
Diameter Pressure | C1................... ..... C2................... ..... C3................... ..... C4................... ..... C5................... ..... C6................... ..... C7................... ..... | PN1.6MPa PN2.5MPa PN4.0MPa PN6.3MPa PN16MPa(Diameter≤25mm) PN25MPa(Diameter≤25mm) PN40MPa*(Diameter≤25mm) |
Explode Request | /NE /EX | Not Explosive Ex ib I or Ex dIIBT4 |
Range of Temperature | /NT /HT | Normal Temperature(<120ºC) High Temperature(≥120 to 150ºC) |
Special Option | / | e.g.:High Temperature,Erode-resistant,Wearable etc. |
| | | | | | | | | | | |
Note:1. The dimensions of connecting flange are in accordance with DIN
2. Mark "*" means apecial order.
Address:
Building 8, Lane 2328, Laiyang Road, Pudong New District, Shanghai
Business Type:
Manufacturer/Factory
Business Range:
Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
Company Profile
Shanghai Foreckon Instrumentation Co., Ltd. Is registered and located in China (Shanghai) Pilot Free Trade Zone, with many advantages of logistics, trading and financial preferential policies by the Chinese government and an easy access to major transportation networks in Shanghai.
Foreckon′s main business covers manufacture and export of instrument, like flowmeters, pressure transmitters, pH meters, etc. Our products are widely used in chemical, petroleum, metallurgy, paper, pharmaceutical, food, environmental protection and scientific research fields. Foreckon has built up a strong manufacture and QC system, as well as an excellent international marketing team, and our customers are from over 90 countries and regions, like North America, Europe, Middle East, Africa and Southeast Asia, etc.
Our high-efficiency Foreckon team will continue to work hard together with our powerful warehousing and logistics partners, and offer high quality product and service to more and more customers all around the world.