Certification: | RoHS, CE |
---|---|
Type: | Far Outside Heating Tube |
Material: | Ni-Cr Wire |
Form: | Single Head Heating Tube |
Shape: | Tubular |
Name: | Immersion PTC Heating Element |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Shape | Width /mm | Thickness /mm | Length in water /mm | Screw or flange | Applied | Surface temperature without water /C | Power |
voltage / V | in 25C | ||||||
water /W | |||||||
Aluminium tube | 13.2 | 5.2 | 75 | as required | 220 | 250 | 100 |
Aluminium tube | 21.5 | 6.8 | 75 | as required | 220 | 260 | 160 |
*Aluminium tube | 21.5 | 12 | 100 | as required | 220 | 260 | 450 |
*Aluminium tube | 21.5 | 24 | 200 | as required | 220 | 260 | 2000 |
round brass tube | Φ11.5 | 75 | as required | 220 | 240 | 100 | |
Stainless steel tube | Φ25 | 200 | as required | 220 | 250 | 1100 | |
Stainless steel tube | Φ35 | 200 | as required | 220 | 250 | 1500 |
Heat intensity | Not exceeding 30Wcm2 (advisable) |
Power | Depends on the dimension |
Escape of current (when cold) | <=0.1mA a 242 v. |
Insulation (when cold) | 5 Min Ohmios 500 Watts minimum |
Dielectric strength | 1500v. 1/seg |
Working temperature | 750ºG max. |
Tolerance of length | +/-1.5% |
Tolerance of diameter | -0.01 a -0.06 m/m |
Tolerance of cut of connexion | +/-15 mlm |
Power tolerance (w) | 5 % - 10 % |
Cold areas | Depends on length and diameter 5-25mm |
Suppliers with verified business licenses