Single phase DC to AC power inverter 10000W 96V 220V UPS
Model: DX10000W
We have the model 1000W~10000W low frequency pure sine wave inverter with charger and LCD display for your choice.
Warranty&Return:
1 year warranty from date of purchase record:
Please email us first if you have any questions or problems with the item received. We will try our best to solve the problem for you.
If we cannot help you through emails, we will give you return instructions.
No refund or replacement will be processed without the item being returned back to us. We reserve the right to refuse any returns for our reasons.
Buyer is responsible for return shipping cost in any situation.
We will not be liable to customer for any damages beyond the amount of money that customer has actually paid us.
Type: |
DX2000W |
DX3000W |
DX5000W |
DX60000W |
DX8000W |
DX10000W |
|
DC12V |
DC24V |
DC48V |
DC12V |
DC24V |
DC48V |
DC48V |
DC48V |
DC96V |
DC96V |
1.AC Mode Specifications: |
Input wave form |
pure sine wave |
Input voltage |
220Vac |
Low voltage cut off |
145Vac±4% |
165Vac±4% |
Low voltage recover |
155Vac±4% |
175Vac±4% |
High voltage cut off |
285Vac±4% |
265Vac±4% |
High voltage recover |
275Vac±4% |
255Vac±4% |
Frequency |
50Hz/60Hz(Atomatic detection) |
Output wave form |
pure sine wave |
Overload protection |
alarm |
Short circuit protection |
trip |
Efficiency |
>95% |
Transfer current |
30A |
60A |
Transfer time DC TO AC |
10ms |
Transfer time AC TO DC |
10ms |
2.Inverter Mode Specifications: |
Rated power |
2000W |
3000W |
5000W |
6000W |
8000W |
10000W |
Power factor |
0~1.0 |
Output voltage |
220Vac |
Frequency |
50Hz ± 0.3Hz |
Automatic tracking the main frequency |
Yes(start from the first connection)50Hz @48-54Hz/ 60Hz @58-64Hz |
Inputvoltage range |
±10% rms |
(-25%/+20%) rms |
Efficiency |
>80% |
Overload protection |
(110%<load<125%) ±10%: 30S cut off output voltage |
(SMPS load) |
(125%<load<150%) ±10%:cut off output voltage at once |
Peak Capacity |
4000VA |
6000VA |
10000VA |
12000VA |
16000VA |
20000VA |
Short circuit protection |
Yes |
Input voltage |
12V/24V/48V/96V |
Min DC voltage |
10V/20V/40V/80V |
Undervoltage warning |
10.5Vdc ± 0.3Vdc (12V battery)/42Vdc±1.2Vdc(48V battery) |
21.0Vdc ± 0.6Vdc (24V battery)/84Vdc±2.4Vdc(96V battery) |
DC input too low, |
10.0Vdc ± 0.3Vdc(12V battery)/40.0Vdc±1.2Vdc(48V battery) |
Automatic cut off |
20.0vdc± 0.6Vdc (24V battery)/80.0Vdc±2.4Vdc(96V battery) |
input voltage warning &cut off |
15Vdc ± 0.3Vdc (12V battery)/30Vdc ± 0.6Vdc(24V battery) |
60Vdc±1.2Vdc(48V battery)/120Vdc±2.4Vdc(96V battery) |
Save power |
load≤25W |
3.Charger Mode Specifications: |
Chargering current |
50A |
25A |
15A |
50A |
25A |
15A |
15A |
15A |
15A |
15A |
Chargering current correction |
± 5Adc |
Battery initial voltage |
0 -13.7 Vdc |
Charger short circuit protection |
trip |
Overcharger protection |
V ≥14.7Vdc / 30.4Vdc, every half second sounds |
4.Charging Rules: |
Three Phases |
constant current chargering →constant voltage phase →float |
5.Monitor |
|
Computer Monitor |
RS232 |
6.Protection |
|
Low Voltage |
LCD show low battery alarm |
High Voltage |
alarm |
Inverter Mode overload |
shut-down protection |
Over Temperature |
Heatsink temperature.≥90°C,shut-down protection |
7.Physical |
|
Operate Temperature Range |
0°C to 40°C |
Store Temperature |
-15ºC ~ 60ºC |
Operate Humidity |
5% to 95% |
Noise |
60dB max |
Cooling |
fan in ventiltation conditions |
Dimension(L*H*W) |
450*215*180MM |
450*215*180MM |
620*215*180MM |
580*290*675mm |
N.W (KG) |
20KG |
20KG |
20KG |
24KG |
24KG |
24KG |
44KG |
46KG |
80KG |
93.5KG |