• Rpm60 Power Meter Multi Meter Network Analyzer
  • Rpm60 Power Meter Multi Meter Network Analyzer
  • Rpm60 Power Meter Multi Meter Network Analyzer
  • Rpm60 Power Meter Multi Meter Network Analyzer
  • Rpm60 Power Meter Multi Meter Network Analyzer
  • Rpm60 Power Meter Multi Meter Network Analyzer

Rpm60 Power Meter Multi Meter Network Analyzer

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Maximum Demand Meter
Electric Equipment: Single-Phase, Two-Phase, Three-Phase
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (24)
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
RPM60
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Customized
Power Consumption
4vamax
Operating Voltage (Un)
85~265 VAC 50/60Hz (Depend on Order)
CT Inputs
4 Current Input: 0.05-5.5A
Voltage Inputs
4 Voltage Input : Max 690VAC (L-L)
Transport Package
Carton Box
Specification
96*96
Trademark
Romaz
Origin
China
HS Code
9030390000
Production Capacity
50000PCS/Month

Product Description

Product Description

Rpm60 Power Meter Multi Meter Network Analyzer
True RMS measurements (512 samples/cycle)
For single-phase, two-phase, three-phase system
Measurements:VL-L,VL-N,1n,Cos Pf,Hz,W,W,Va,Va,Var,Var,lmport Kwh,
  export Kwh,lmport Kvarh,export Kvarh,V-THD,I-THD,1-63th harmonlc,system runninghours,% voltage unbalance,
  %currentuhbalanoe,%system load, total frequency
3 voltage and 4 current input(Measure or calcu late the neutral current)
Detects CT wiring errors
Maximum, minimum and demand for U,I, P, Q Sin hours, days, months
Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
%system load and system running hours
Real time clock with in teg rated b ackup recha rge ab le battery
4 quadrants energy measure and monthly energy calculation
2 pulse output and RS485 communicatlon: Modbus RTU
Alarm event log
Built in 1Mblt memory
English, Chnese (traditlonal & smplled or Otherlanguage
Moduel functlon optlons (only one can be selected)
   - 7 digital input +2 relay output(remote or alarm)(Standard)
   - 7 digltal input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,11,12,13 (option)
   - Ethemnet (Modbus TCP), Web server+2 digltal input +2relay output(remote or alarm) (option)
   - LoRa wireless (Prlvate protocol)+2 digltallnput+2 relay output (remote or alarm)(option)
   - RS-485 interface (Modbus RTU)+2 digltal input+2 relayoutput (remote or alarm)(option)
   - WIFl wireless +2 digltallnput +2 relay output(remote oralarm)(option)

Product Parameters

Auxiliary Supply
Operating voltage (Un) 85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order)
Power consumption 4VA max
Measurement input
Voltage inputs for direct connection: Phase-neutral(L-N): max 400V RMS CAT III
Input impedance(for direct voltage inputs): >4MΩ
CT inputs: max 5.5A RMS
CT inputs overload capacity: max 10A
CT inputs Self-consumption : < 0.2VA
Accuracy
Three phase voltage: ± 0.2%
Currents: ± 0.2%
Powers: ± 0.5%
Powers factor: ± 0.5%
Frequency: ± 0.02%
Harmonics: ± 1%
Active energy: Class 0.5S
Reactive energy: Class 0.5S
Insulation
Insulation voltage
3kV for 1 min., 50Hz
Display
Display type
3.2inch 240x160 pix LCD
I/O
Digital inputs:
Active dry contact
Digital outputs:
2 Relay N/O 220VAC 5A
Analog outputs:
4-20mADC / max load 500Ω
Pulse output:
24-30VDC Max.50mA, Min. 50msec pulse width
Memory  
Recording memory:
Built in 1Mbit memory
Communication
Ethernet port:
Auto MDIX Rj45 10/100 Base Ethernet
RS-485 port:
1 optoisolated, 4800-57600
Protocols:
HTTP, HTTPS, Modbus RTU/TCP
Environmental conditions
Opterating temperature:
-10···+55°C
Storage temperature:
-25···+75°C
Relative humidity:
95% max without condensing
Altitude:
max 2000m AMSL
Installation & use:
Internal
Mechanical characteristics
Mounting:
Panel mount 96x96mm(The panel cut-size 92*92mm)
Size:
Front(WXH)96x96mm, Rear (HxD) 90x70mm
Degree of protection:
IP40(optional IP54) on front, IP20 housing and terminals
Weight:
400g
Standard compliance
reference standard:
IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21;
IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30;
IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2;
IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6;
IEC61000-4-8; IEC61000-4-11; IEC61000-4-30

Rpm60 Power Meter Multi Meter Network Analyzer

Installation Instructions

Rpm60 Power Meter Multi Meter Network Analyzer

Company Profile

Rpm60 Power Meter Multi Meter Network Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
11
Year of Establishment
2020-12-09