• Rpm40 Power Meter Multi Meter
  • Rpm40 Power Meter Multi Meter
  • Rpm40 Power Meter Multi Meter
  • Rpm40 Power Meter Multi Meter

Rpm40 Power Meter Multi Meter

After-sales Service: 2 Years
Warranty: 2 Years
Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Maximum Demand Meter
Electric Equipment: Single-Phase,Two-Phase,Three-Phase
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (24)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
RPM40
Theory
Electronic Meter
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Power Meter
Certification
RoHS, ISO, CE
Customized
Customized
Power Consumption
3vamax
Operating Voltage (Un)
85~265 VAC 50/60Hz (Depend on Order)
CT Inputs
3 Current Input: 0.05-5.5A
Voltage Inputs
4 Voltage Input : Max 690VAC (L-L)
Transport Package
Carton Box
Specification
96*96
Trademark
Romaz
Origin
China
HS Code
9030390000
Production Capacity
50000PCS/Month

Product Description

Product Description

Rpm40 Power Meter Multi Meter
True RMS measurements
For single-phase, two-phase, three-phase system
Measurements:VL-L, VL-N, I, In, Pf, Hz, W, ΣW, Va, ΣVa, Var, ΣVar, import Kwh,
   export Kwh import Kvarh, export Kvarh, V-THD, I-THD, system running hours,
   % voltage unbalance, % current unbalance, % system load, total frequency
3 voltage and 3 current input (Calculate the neutral current)
Maximum, minimum and demand for U, I, P, Q, S in hours, days
Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
 % system load and system running hours
4 quadrants energy measurement support bi-directional power monitoring includes
  measurement on regenerative loads
RS485 communication: Modbus RTU
English, Chinese (traditional & simplied) or Other language

Product Parameters

Auxiliary Supply
Operating voltage (Un) 85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order)
Power consumption 4VA max
Measurement input
Voltage inputs for direct connection: Phase-neutral(L-N): max 400V RMS CAT III
Input impedance(for direct voltage inputs): >4MΩ
CT inputs: max 5.5A RMS
CT inputs overload capacity: max 10A
CT inputs Self-consumption : < 0.2VA
Accuracy
Three phase voltage: ± 0.5%
Currents: ± 0.5%
Powers: ± 0.5%
Powers factor: ± 0.5%
Frequency: ± 0.02%
Harmonics: ± 1%
Active energy: Class 0.5S
Reactive energy: Class 0.5S
Insulation
Insulation voltage
3kV for 1 min., 50Hz
Display
Display type
3.2inch 240x160 pix LCD
Communication
RS-485 port:
1 optoisolated, 4800-57600
Protocols:
Modbus RTU
Environmental conditions
Opterating temperature:
-10···+55°C
Storage temperature:
-25···+75°C
Relative humidity:
95% max without condensing
Altitude:
max 2000m AMSL
Installation & use:
Internal
Mechanical characteristics
Mounting:
Panel mount 96x96mm(The panel cut-size 92*92mm)
Size:
Front(WXH)96x96mm, Rear (HxD) 90x70mm
Degree of protection:
IP40(optional IP54) on front, IP20 housing and terminals
Weight:
350g
Standard compliance
reference standard:
IEC61010-1;IEC61557-12; IEC62053-22; IEC62053-23;
IEC61326-1; 
EN55011; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2;
IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6;
IEC61000-4-8; IEC61000-4-11; IEC61000-4-30

Detailed Photos

 

Rpm40 Power Meter Multi Meter
Rpm40 Power Meter Multi MeterRpm40 Power Meter Multi Meter
 

Installation Instructions

Rpm40 Power Meter Multi Meter

Company Profile

Rpm40 Power Meter Multi Meter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
11
Year of Establishment
2020-12-09