• Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
  • Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
  • Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
  • Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
  • Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
  • Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center

Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center

Certification: REACH, ISO 9001
Environmental Protection: Yes
Function: Heat Transfer/Device Cooling
Appearance: Liquid
Color: Colorless
Chemical Activity: Inertness
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (16)
  • Overview
  • Detailed Photos
  • Product Description
  • Application
  • Product Parameters
  • Packaging & Shipping
  • FAQ
  • Exhibition photos
Overview

Basic Info.

Model NO.
JHT-200
Material Compatibility
Metals, Plastics, Rubbers and Elastomers
Conductivity
Dielectric
Safety
Non-Toxic
Transport Package
Barrel
Specification
5kg/20kg/1t/barre
Trademark
JH
Origin
China
HS Code
3824999999
Production Capacity
8tons/Month

Product Description

Detailed Photos
Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center
Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center

 

Product Description

Product description:
Perfluoropolyethers (abbreviated as PFPE), Juhua's JHT series PFPE products are perfluoropolyethers heat transfer fluids. They are dielectric fluids with current boiling points ranging from 135 to 270ºC. Their excellent dielectric properties, high chemical stability combines with the capacity to operate at very low temperatures as well as elevated temperatures make them the best heat transfer fluids for the aggressive conditions.

Their properties are as follows:
1. Compatible with most materials over a wide temperature range.
2.Thermally stable and chemically inert.

3.Excellent dielectric properties: high electrical resistivity and low dielectric constant.
4. Low viscosity.
5.No flash point, fire point or toxicity. This product is designed with environmental friendliness, your health and safety in mind. You can use it with peace of mind even at aggressive conditions.
6. No flash point, fire point or toxicity. This product is designed with environmental friendliness, your health and safety in mind. You can use it with peace of mind even at aggressive conditions.

 
Application

Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data CenterApplication:
The overall application areas include:

semiconductor, pharmaceutical, chemical, aviation, and LCD screen manufacturing.
Subdivided into: 
(1) Component impregnation, wafer etching, ion implantation, producting uranium hexafluoride and removing 
particulate impurities.
(2) Cleaning: electronic instruments, laser discs, touch screen surfaces, optical systems and precision
applications.
(3) internal heat dissipation of wind turbines and generator sets.
(4) Cooling: high-voltage transformers, data centers, radar, transformers, power supply units, refrigerators, cooling towers, and freeze-drying machines.


 

Product Parameters

Product parameters:
Main properties JHT-200
Appearance colorless
Boiling point/ºC 200
Pour point/ºC -85
Density/g·cm-3 1.79
Kinematic viscosity/cSt(@25ºC) 2.9
Specific heat/J·kg-1·K-1 960
Thermal conductivity/W·m-1·K-1 0.065
Dielectric strength/kV(2.54mm) 40
Dielectric constant < 2
Volume resistivity/Ohm·cm > 1.0·1015
Dissipation factor(1khz) 2·10-4
Solubility of water/ppm(wt) < 10
 
Packaging & Shipping

It is required to store in a clean, dry, and cool warehouse to avoid prolonged exposure to air. It can be transported as non hazardous chemicals, and they should be kept away from pollution, sunlight, and water during transportation.

Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center

FAQ

Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center

Exhibition photos

Replace Galden Pfpe Perfluoropolyether Jht-200 Heat Transfer/Cooling Fluid for Semiconductor, Data Center




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2024

Suppliers with verified business licenses

Trading Company
Number of Employees
30
Year of Establishment
2018-10-11