• Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
  • Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
  • Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
  • Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
  • Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
  • Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

Warranty: 2 Years
Display: LCD Display
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment: DC Energy Meter
Theory: Static Meter
Samples:
US$ 82.60/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shanghai, China
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Overview
  • Product Description
  • Application
  • Product Parameters
  • Wiring Chart
  • Installation Instructions
  • Solution
  • Company Profile
Overview

Basic Info.

Model NO.
PZ72L-DE
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE
Customized
Customized
Communication
RS485 Modbus-RTU
Frequency
45~60Hz
Application
EV Charging Pile, Solar PV
Rated Voltage
0~1000V DC
Measurement
1-Circuits DC Voltage, Current, Power, Kwh
Transport Package
Carton
Specification
DC meter
Trademark
Acrel
Origin
China

Product Description

 

DC Multi-function Energy Meter PZ72L-DE

Product Description
 

Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorPZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations, and charging posts. This series of instruments can measure voltage, current, power, and forward and reverse power in a DC system. It can be used for local display and connected with industrial control equipment, and computers, to form a measurement and control system. And it has a variety of external excuse functions for the user to choose: from RS485 communication interface, Modbus-RTU protocol, relay alarm output, and digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, and communication parameters. The product meets the relevant technical requirements of the standard Q/GDW1825-2013 DC power meter specification, GB/T29318-2012 Non-vehicle charging electric energy metering for electric vehicles, Q/GDW364-2009 Single-phase energy meter specification.

Picture Description Optional Function
Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor Measurement: 1-circuit DC kWh, kVarh, U, I, P and etc
 Accuracy: 0.5%
 Rated Voltage: 1000V DC
 Rated Current: 10A DC (direct connect); 0/4~20mA DC (via Hall Sensor); 75mV (via Shunts)
 Power Supply: 85~265V AC/DC; 20~60V DC
 Standard&Certificate: CE Certificates
Local display
Measure voltage, current, power, forward and reverse power in DC system
Set parameters
Applications:DC panels, solar power, telecommunications base stations, and charging posts
 Communication: RS485 (MODBUS-RTU)
 DI/DO Function: 2/4-channel DI&2-channel DO
 ±12V Power Ouput: Paired with Hall Sensor
 Multi-rate/tariff:4 Tariff Rates and etc
Relay alarm output
Application

Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

 
Product Parameters
1. Function Overview
Function
Description&Value
Measurement
1-circuits DC Voltage, Current, Power, kWh
Display
LCD display
Communication (Optional)
RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity) Baud Rate 1200~38400 bps etc.
DI/DO Switching (Optional)
DI (Digital input): 2-channel digital input,dry contact, built-in power supply DO (Digital output): 2-channel digital output (relay output) with NO Contact, Capacity: 2A/30V DC or 2A/250V AC
±12V Power Output (Optional)
Serve as the power supply for 1 Hall Sensors with ±12V DC
Multi-rate/tariff (Optional)
2 Time Schedules; 4 Time Zone for a year; 12 time periods by days set for 1 time schedule; 4 Tariff Rates (Spike, Peak, Flat, Valley); Min. Time Interval=15 min.
2. Main Parameters
Parameter
Description&Value
Input
Rated Voltage
DC Voltage Input: 0~1000V DC (via direct connetion); Input Resistance: ≥ 6kΩ/V
Rated Current
DC Current Input: 10A DC (via direct Connection); 0~20mA or 4~20mA (via Hall Sensors); 75mV (via Shunts)
Overload
Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second
Power Consumption
Power consumption of each current input circuit is less than 1mW
Measuring Accuracy
Class
0.5%
Power Supply
Voltage Range
85-265V AC/DC; 20~60V DC (±20%)
Power Consumption
≤ 2W
Pulse Constant
Voltage and current specifications:750V,300A,Default pulse constant:100imp/kWh
Voltage and current specifications:1000V,300A,Default pulse constant:100imp/kWh
Insulation resistance
≥ 100MΩ
Power frequency withstand voltage
Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min; Between Power supply,switching output,Current Input,voltage Input AC 2 kV 1min; Between Transmitting,Communication,Pulse Output,switching input AC 1kV 1 min;
3. Environment
Condition
Description&Value
Temperature
Operation: -25ºC~+65ºC; Storage: -40°C ~+80°C
Humidity
≤95%RH,no condensation,without corrosive gas
Altitude
≤ 2500m
Wiring Chart

DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (75mV DC) input via -/75mV Shunts


Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

DC Voltage Signal (1000V DC) Input via direct Connection & DC Current Signal (0~20mA or 4~20mA DC) input via Hall Sensors
Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
Installation Instructions

 

Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

 

 
Solution
Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor
 
Company Profile

 

Relay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV MonitorRelay Alarm Output Optional Acrel Pz72L-De LCD Display Electric DC Power Watt Energy Meter Monitor Application for Charging Piles and Solar PV Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
291
Year of Establishment
2003-06-23