• Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
  • Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
  • Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
  • Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
  • Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
  • Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan

Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan

Application: Power
Phase: Three
Core: Core-type Transformer
Samples:
US$ 100000/Piece 1 Piece(Min.Order)
| Order Sample
Contact me for more information and pricing on sam
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan pictures & photos
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
US $125,000-298,000 / units
Min. Order: 1 units
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Jiangsu, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Customization from Designs
The supplier provides design based customization services
Product Certification
The supplier's products already have relevant certification qualifications, including:
UL
to see all verified strength labels (23)

Basic Info.

Model NO.
SSZ
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, UL/cUL
Usage
Power Transformer
Frequency Characteristics
50/60Hz
Shape of Core
Stacked
Brand
Daelim Transformer
Type
Oil-Filled Power Transformer
Capacity
20mva 150mva 200mva
Standard
IEEE/CSA/as
MOQ
1 Unit
Winding Material
Copper
Cooling
Oana/Knan
Core Material
Silicion Steel
Frequency
50/60Hz
Output Voltage
13.2kv 13.8kv 11kv
Input Voltage
69kv 110kv 132kv 138kv
Tap Changer
Oltc/Nltc
Temperature Rise
55/65
Insulation Oil
Mineral Oil, Vegetable Oil
Tank
Silicon Carbon Steel
Oil Tank Material
Stainless Steel
Transport Package
Tray
Specification
S-10000/69-4.15
Trademark
DAELIM
Origin
China
HS Code
850421
Production Capacity
20 Units/Month

Packaging & Delivery

Package Size
356.00cm * 330.00cm * 340.00cm
Package Gross Weight
6000.000kg

Product Description

Power Transformer

Power transformers are a core component of power transmission system. The substation transformer used for power transmission and transformation in a unit or substation, and is also the core part of the substation. Transformers are the core equipment of the traction power supply system of electric locomotives, and also the key equipment to ensure the safe and stable operation of the traction power supply system.
 

Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan

 

Product Description

Design and Manufacture Standard ANSI-IEEE 57. 12/CSA/EN/BS/GOST/AS,IEC 600761

 

Design

Sealed-tank system /Inert-gas pressure system or Conservator-tank system without diaphragm

On load or no load voltage tap changer

 

ONAN/ONAF/ODAF/OFAF/OFWF/KNAN/KNAF

 

Insulation

 

Mineral Oil Inhibited I Not Inhibited I Vegetable oil

 

Primary voltage

 

Up to 230kv, up to 900kv BIL

 

Capacity

 

Up to 240MVA

 

Frequency

 

50/60 HZ


Operating Condition

Suitable for indoor and outdoor application.
Ambient temperature: -50 ºC~40 ºC
Relative humidity: ambient air relative humidity should be below93%,
Altitude: ≤1000m
Max wind speed: ≤35 m/s
Earthquake acceleration: horizontal acceleration ≤0.3g    
vertical acceleration ≤0. 15g
Special conditions: customized products are available.

STANDARD FEATURES
Capacity range:Through 60 MVA (ONAN), with high-voltage  
ratings through 230 kV (900 kV BIL)
Service Location: Outdoor
Core: Regular grain-oriented; mitered cruciform with step-lap  construction
Coils: Cylindrical construction; all copper windings, custom tempered per design requirements; circular windings with rectangular or continuously-transposed conductor; helical low-voltage  windings;  continuous disc medium-voltage windings; shielded disc high-vollage windings
Radiators: Detachable panel type with shut-off valves; mild steel
Insulating oil: mineral oil type  I & typell
Tank  Cover.Welded,  
Bolted Manholes: On cover or tank
Tank Base: Flat bottom or Skid under base
Tank  Material:  Mid  Steel
Frequency:  60  Hertz Winding  
Tem  rise:  55 ºC
HV Taps; DETC, ETC in tank or out
- Above rated volts: 2 x2- 1/2% off load taps of full capacity    
-Below rated volts: 2 x 2- 1/2% off load laps of full capacity
Valve: Drain and Fiter Valves, w/Sampler                                
Lifting, Moving, and Jacking Facilities
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan

Technical Data

Technical Data for 69KV Class Three Phase Two Winding OLTC Power Transformer
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
10000 69 6.3
6.6
10.5
11
YNd11 9 12.1 47.6 0.75
12000 12.6 56.5 0.53
15000 15.1 69.5 0.49
20000 17.9 84.2 0.49
25000 21.1 99.5 0.42
30000 25.1 120 0.42
37500 30 140.3 0.39
50000 35.4 174.3 0.39
60000 42.1 210 0.39

Technical Data for 69KV Class Three Phase Two Winding NLTC Power Transformer
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
10000 69 6.3
6.6
10.5
11
YNd11 9 11.6 47.6 0.75
12000 13.6 56.5 0.53
15000 16.3 69.5 0.49
20000 19.2 84.2 0.49
25000 22.6 99.5 0.42
30000 26.8 120 0.42
37500 31.9 140.3 0.39
50000 38.6 174.3 0.39
60000 44.4 210 0.39

Technical Data for 115KV Class Three Phase Two Winding OLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
10000 115
138
161
6.3
6.6
10.5
11
YNd11 10.5 11.8 51.2 0.82
12000 13.7 59.5 0.82
15000 16.3 73.1 0.76
20000 19.5 88.4 0.76
25000 22.7 105 0.69
30000 27.4 126 0.69
37500 32.9 148 0.63
50000 38.9 184 0.63
60000 46.4 221 0.57

Technical Data for 115KV Class Three Phase Two Winding NLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
10000 115
138
161
6.3
6.6
10.5
11
YNd11 10.5 10.5 50.2 0.64
12000 12.4 59.5 0.64
15000 15 73.1 0.59
20000 17.8 88.4 0.59
25000 21 105 0.54
30000 25 126 0.54
37500 29.9 148 0.56
50000 35.3 178.5 0.52
60000 41.9 221 0.48

Technical Data for 230KV Class Three Phase Two Winding OLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
30000 230 6.3
6.6
10.5
11
34.5
66
YNd11 12 30 128 0.69
37500 36 149 0.63
50000 43 180 0.63
60000 50 209 0.57

Technical Data for 230KV Class Three Phase Two Winding NLTC Power Transformer 
(KVA)
Rated Power 
(KV)
High Voltage
(KV)
Low Voltage
Connection Symbol Short Circuit
Impendence (%)
No-load Loss (KW) On-load Loss (KW) No load Current (%)
30000 230 6.3
6.6
10.5
11
34.5
66
YNd11 12 28 128 0.7
37500 33 149 0.7
50000 39 180 0.65
60000 46 209 0.65

Transformer Test
Winding   resistance Winding insulation resistance
Core insulation resistance Ratio
Polarity and phase relation Insulation power factor
Control(auxiliary) cooling losses Single-phase excitation tests
Noload losses and excitation current Impedance voltage and  load  losses
Zero-phase  sequence   impedance  voltage Temperature   rise
Low frequency dielectric tests Low frequency dielectric tests on axiliary devices
control, and current transformer circuits Lightning  impulse
Front of wave impulse Swithing   impulse
Partial discharge Audible  sound  level
Operational tests (all devices) Dissolved gases in oil
Leak  test  
 
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
Sales Record

Daelim's transformers are sold to nearly 100 countries including the United States, Canada, Mexico, Ecuador, Chile, and Australia. The picture below is part of the sales record.
 
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan


DAELIM BELEFIC

Daelim Belefic builds power translormers that deliver power to the consumer efficiently and reliably.

Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
Our single-phase and three-phase winding or autotransformer are according to international standards such as ANSI/IEEE/IEC/CSA/AS as well as NEMA standards, etc, the power ratings are up to 270 MVA and for vollages up to the highest insulation class of 900 kV.

 

Daelim's transformers have been exported to America, Canada, Mexico, Australia, Chile, Ecuador, Venezuela, Honduras, El Salvador, Panama and other countries. DAELIM have helped many international customers to successfully obtain transformer projects and continue to carry out in-depth cooperation.

DAELIM have 20 years of transformer export experience, moreover DAELIM have after-sales installation teams overseas, so if you also have transformer business, we can develop together.

Daelim Transformer High Quality Service

a.pre-sales


Daelim has a very serious quality control system, strictly controlling every detail from transformer design to raw material procurement, assembly, testing, packaging and delivery.

b.after sales

1.Up to 24 months quality guarantee period. If there is any problem in the operation of your transformer, Daelim's after-sales team will solve it promptly and quickly;

2.Local after-sales installation service team. Whether you are in North America, South America or other regions, Daelim's local team can provide you with professional transformer installation, commissioning, maintenance and other services;

3.Daelim provides remote video guidance for transformer installation.



Thank you for reading. If you need inquiries, please contact us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan pictures & photos
Power Electrical 40mva 30mva 66kv 69kv Oil Immersed Transformer with Cooling Fan
US $125,000-298,000 / units
Min. Order: 1 units
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
67
Year of Establishment
2019-08-20