• Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
  • Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
  • Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
  • Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
  • Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
  • Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs

Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs

Warranty: 12 Months
Brand: Yuan Zheng
Customized: Customized
Portable: Portable
Gas: Methanethiol, Dimethyl Sulfide,Methyl Disulfide
Type: Infrared Absorption Analyzer
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
YZ-POGA-100
Measurement Technology
Spectral Absorption Method
Zero Drift
≤ ±3%F.S./24h
Span Drift
≤ ±3%F.S./24h
Linearity Error
≤ ±3%F.S.
Communication Protocol
Hj 212, Modbus-RTU
Communication Interface
GPRS/4G
Working Temperature
-10ºC~+30ºC
Power
(220±22)VAC, 50/60Hz, 120W
Transport Package
Carton Box
Specification
15 Kg
Trademark
YUAN ZHENG
Origin
China
Production Capacity
1000

Product Description

YZ-POGA-100 Odorous Gas Analyzer
YZ-POGA-100 Portable Gas Analyzer is developed for detection and warning of accident odor emission, comparative investigation of pollution sources, and rapid detection of ambient air odor gas.  The analyzer is based on ultraviolet differential absorption spectrum (DOAS) technology.

It can detect a variety of odorous gases simultaneously.  And it can be expanded to detect TVOCs, benzene, methylbenzene and other gases according to user needs. Besides, it can also be configured with high-temp heating pipe, and condensation pretreatment system, that can realize the simultaneous monitoring of odor gas and flue gas pollutants.



Features:
  • PLS algorithm, can effectively eliminate the cross interference between the components;
  • Built-in High-quality thermostatic components, small temperature drift, strong environmental adaptability;
  • Equipped with long-life pulse xenon lamp light source, no optical moving parts, high stability
  • Equipped with high-resolution spectrometer, low detection limit, suitable for rapid detection of odorous gases in the ambient air;
  • Equipped with a fast-automatic cleaning module, can perform gas analysis under harsh working conditions without any risk of gas chamber pollution;
  • Optional large capacity mobile power supply, fixed pollution source emission pretreatment system, portable sampling system, and other accessories can be equipped. Achieve rapid detection of organized emissions of odorous gases from fixed pollution sources;
  • Optional automatic sample retention system. Accurate analysis for both laboratory and on-site conditions;

Application:
  • Monitoring of unorganized emission sources from enterprises and chemical parks;
  • Monitoring of odorous gas emissions from urban sewage treatment plants and landfills
  • Rapid analysis of odorous gases from fixed pollution sources;
  • Rapid analysis of odorous gases from unorganized emission sources;
Specification:
 
Factors Measuring range Solution
methyl mercaptan 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
methyl sulfide 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
dimethyl disulfide 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
hydrogen sulfide 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
trimethylamine 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
carbon disulfide 0~10, 0~1 ppm (ultra-low) 50,10 ppb (ultra-low)
ammonia 0~50, 0~5 ppm (ultra-low) 100,50 ppb (ultra-low)
styrene 0~10, 0~1 ppm (ultra-low) 50,10 ppb (ultra-low)
TVOC 0~10, 0~1 ppm (ultra-low) 50,10 ppb (ultra-low)
OU 0~50000, 0~10000ppm (ultra-low) 5,1 ppb (ultra-low)
Measuring principle: UV-DOAS:  C2H6S, C2H6S2, C3H9N, C6H6, CS2, H2S, NH2, etc;
PID:  TVOCs;
Empirical formula:  Odor/OU;
Zero drift: ±3%F.S./24h
Span drift: ±3%F.S./24h
Linearity error: ±3%F.S.
Communication Interface: GPRS/4G
Digital input: 4 inputs, can be configured
Digital output: 4 inputs, can be configured
Power supply: (220±22)VAC, 50/60Hz, 120W
Working condition: Temperature: -10ºC~+30ºC,
Humidity:≤90%RH,no condensation


Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs
Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, TvocsPortable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, TvocsPortable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, TvocsPortable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, TvocsPortable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
30000000 RMB
Plant Area
101~500 square meters