• P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s
  • P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s
  • P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s
  • P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s

P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s

After-sales Service: Supplied, Onsite, Online
Warranty: 1.5 Years
Brand: Cape Golden
Customized: Customized
Portable: Portable
Certification: CE
Samples:
US$ 420/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Beijing, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
Medical Device Quality Management System Certification
to see all verified strength labels (16)
  • Overview
  • Product Description
  • Our Advantages
Overview

Basic Info.

Gas
O2
Type
Electrochemical Gas Analyzer
Transport Package
Sea/Air Packing
Specification
P860
Trademark
Cape Golden
Origin
Beijing, China.
HS Code
9027100090
Production Capacity
200 Units Per Month

Product Description

P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s
Product Description

 

P860 Nitrogen Oxygen Analyzer Portable Oxygen Purity Analyzer 100ppm~21%

P860 series analyzer is the online intelligent measurement instrument, which adopting advanced ion current oxygen sensor with single chip technology. N2%=100%-O2%. It has been widely used in the fields of nitrogen separation from air, fertilizer, petrochemicals and biological fermentation.

Features

  • New pattern long-life conversion ion current tester with fast response and high sensitivity
  • N2 or O2 concentration display
  • Checking the sensor working state automatically and unique double-line working change mode extending the sensor's life
  • Setting alarm value freely
  • High precision, automatic temperature compensation, eliminating the impact of environmental temperature
Our Advantages

P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2sTechnical Parameters
Model: CI-PC21
Measuring principle: NDIR non-optical infrared analyzer
Measuring component: any one or two components can be measured NOx,SO2,CO,CO2,CH4,H2S. O2 Can be added to each component

Range based
Required design
Minimum Range Maximum range
NOx 0 to 1000 ppm 0-20%
SO2 ppm 0-500 0-100%
CO 0 to 20 ppm 0-100%
CO2 0 to 10 ppm 0-100%
CH4 0 to 200 ppm 0-100%
H2S 0 to WOO ppm 0-30%
 
Accuracy ± 2%FS
Repeatability ±1%FS
Zero Drift ±1%FS/7d
Range Drift ±1%FS/7d
Linear Error Limit ±1%FS
Response Time T90<=60 s (sample flow 0.5 L/min)
Analog Signal 4~20 mA/0~20mA/0~1 V/0-5V/0-10V/1-5V, can set analog output mode freely
Maximum Load provided according to user requirements, not affected by load within 500Ω maximum load
Ambient Temperature -10~45°C
Ambient Humidity less than 80% RH
Supply voltage 85-264 VAC 50/60HZ
Size 19-inch profile chassis L * W * H=483 mm * 300mm *177mm
Gas flow measured 500~1000 ml/min, 500 ml/min best
Dust particles not exceeding I um, not exceeding 200 μg/Nm3
Pressure 10%± atmospheric pressure (air outlet should be atmospheric pressure)
Moisture no more than 5 P saturated (no condensation)

P860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2sP860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2sP860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2sP860 Infrared Nitrogen Oxygen Gas Analyzer for Co CO2 Nox So2 CH4 H2s

1.Q:Where is your factory located? How can I visit there?
A:We are the professional gas equipments, founded in 2008. Our factory is located in Beijing China . Welcome to visit us!
2.Q:What's your delivery time?
A:As usual 40 days,if urgently order,pls contact our sales in advance.
3.Q:How does your factory do regarding quality control?
A:Quality is everything. we always attach great importance to quality controlling from the very beginning to the very end. Our
factory has gained ISO9001 and CE certificate.
4.Q:What's payment term?
A:T/T, L/C etc.Also we could accept USD, RMB, Euro and other currency.
5.Q:How about your after-sales service?
(1) Provide customers with installation and commissioning online instructions.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after service available.

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
101~500 square meters