This product is no longer promoted on Made-in-China.com. If you find any infringement or sensitive information of it, please contact us for handling. Thank you.

OEM Tank Battery 2020 12V 100ah Deep Cycle Mf Gel Lead Acid Battery for Tank Starting or for Truck High Performance

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
TANK 100-12
Rechargeable
Chargeable
Transport Package
Carton
Specification
181*265*240MM
Trademark
OCEAN
Origin
China
HS Code
85072000
Production Capacity
50000PCS/Year

Product Description

Deep Cycle Maintenance Free Starting Battery 12V100ah for Military Tank Battery



 
Item                          Specification
General Information
1. Battery Type AGM, Pure Lead, Valve Regulated Lead Acid Monobloc Battery, Type: AGM 6TNB120
2. Nominal Capacity at 5 hr rate to end 9.0V/bloc (1.60vpc) at 25°C
Nominal Capacity at 20 hr rate to end 10.5V/bloc (1.75vpc) at 25°C
100 Ah

120 Ah
3. Nominal Voltage of Monoblock 12V
4. Normal operating temperature +20ºC to +30ºC
5. Operating temperature limits -40ºC to +50ºC, +70ºC Intermittent operations.
Mechanical Data 
6. Dimensions in mm See figure 1 below
7. Weight in Kg (Approx.) 38 Kg
Electrical Data 
8. CCA at -18ºC, 30seconds to end 7.2V (SAE J 537) 1225 Amps
9. Internal resistance in milli ohms 2.0 mW (approx.)
10. Ampere-hour efficiency 95% (minimum)
11. Watt-hour efficiency 85% (minimum)
12. Charging Voltage 14.4V per 12V monobloc
  a) Cyclic Application
13. Charging Current 10A (minimum) in Constant Voltage mode 100A (maximum) in Constant Voltage mode
Design Data 
14. Type of plate Thin, flat, pasted
15. Thickness of plates 2.0 mm (max.)
16. Type of Separator Absorptive Glass Mat (AGM)
17. Grid Alloy Pure lead
18. Material of container and lid ABS
19. Type of sealing Fusion sealing
20. Electrolyte Dilute sulphuric acid in totally absorbed condition



Q1: Are you a battery manufacturer, and do you produce the plate by yourself ?
A: Yes, we are a professional battery manufacture in Foshan city, Guandong, China. And we produce plates by ourselves.
Q2:How about your delivery time usually?
A: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products
Q3: What certificate your company have?
A: ISO 9001, ROHS, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
Q4 :What is your warranty time for VRLA battery ?
A: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements
Q5. Can your battery be delivered by sea and air?
A: Yes, our batteries can be delivered both by sea and by air. We have MSDS. test report for safe transport as  non-dangerous products
Q6. Can I put my logo on the battery?
A: Yes. you can print your logo on our batteries when you order reach 20ft container quantity. If not. price will be negotiated
Q7. What is the shelf life of VRLA battery and how to maintain the battery?
A: The limiting factor of battery's shelf life is the rate of self-discharge which itself is temperature dependent. VRLA batteries will self-discharge less than 3% per month at 77° F (25° C). VRLA batteries should not be stored for more than 6 months at 77° F (25° C) without recharged if in hot temperature, recharge it every 3 month When batteries are taken out of long storage, it is recommended to recharge before use
Q8. Can I fast charge my battery?
A: Fast charging is not recommended as ifs harmful for the battery
Q9. Why battery has different capacity at different hour rate?
A: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
Q10. Can I do a partial replacement of my batteries?
A: Partial battery replacement of lead acid battery banks are not recommended
Q11.How does your factory control the quality?
A: We Adopt ISO 9001 quality system to control the quality. We have Incoming Quality Control (IQC) department to test and confirm raw material meets high quality producing requirements, Production Quality Control (PQC) department contains The first Inspection, in-process quality control, acceptance inspection and full inspector), Outgoing Quality Control (OQC) department confirm no defective batteries come out from the factory.
Q12. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.

Q13. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
128
Year of Establishment
2009-06-01