Principle of Work: Slip Frequency Control Transducer
Main Circuit Type: Current
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Brand: Siemens
Degree of Protection: IP20 / UL Open Type
Net Weight: 0.49 Kg (1.08 Lb)
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
6SL3244-0BB12-1PA1
Width
73.0 mm (2.87 in)
Height
199.0 mm (7.83 in)
Depth
46.0 mm (1.81 in)
Compliance with Standards
CE,cUL, cUL, Rcm, Semi F47
Transport Package
Carton
Specification
CE marking Low-voltage directive 2014/35/EC
Origin
Great Britain
HS Code
8537101101
Production Capacity
99999pieces/Year

Product Description

6SL3244-0BB12-1PA1 SINAMICS G120 CONTROL UNIT CU240E-2 PN  Frequency Drive VFD
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control


Control Unit CU240E2
CU240E2 DPF Control Unit
The Control Unit performs closed-loop control functions for the converter.
The CU240E2 Control Unit is designed as standard Control Unit for all of the usual applications involving V/f or vector control.
  • CU240E-2 series with standard I/O quantity structure and integrated safety technology
The CU240E2 Control Unit can be combined with the following Power Modules:
  • PM2402
  • PM250
Note:
Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.

Safety Integrated Functions
The Safety Integrated Function "Safe Torque Off" (STO) (certified according to IEC 61508 SIL 2 and EN ISO 138491 PL d and Category 3) is already integrated into the basic versions of the CU240E2 series (CU240E2, CU240E2 DP, CU240E2 PN).
With the fail-safe variants of the CU240E-2 series (CU240E2 F, CU240E2 DP-F, CU240E2 PN-F), the fail-safe SINAMICS G120 converter provides five safety functions which are certified according to IEC 61508 SIL 2 and EN ISO 138491 PL d and Category 3:
  • Safe Torque Off (STO)
    to protect against active movement of the drive
  • Safe Stop 1 (SS1)
    for continuous monitoring of a safe braking ramp
  • Safely-Limited Speed (SLS)
    for protection against dangerous movements when a speed limit is exceeded (the CU240E2 DP Failsafe Control Unit has 4 selectable SLS limit values)
  • Safe Direction (SDI)
    This function ensures that the drive can only rotate in the selected direction.
  • Safe Speed Monitor (SSM)
    This function signals if a drive operates below a specific speed/feed velocity (CU240E2 DPF / CU240E2 PNF with PROFIsafe).
These functions can be activated by means of PROFIsafe or via the safety inputs.
None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
CU240E2, CU240E2 DP, CU240E2 PN, CU240E2 F, CU240E2 DPF and CU240E2 PNF Control Units
Terminal No. Signal Features
Digital inputs (DI) - Standard
5 ... 8,
16, 17
DI0 … DI5 Freely programmable (isolated) 5.5 mA/24 V
69 DI COM1 Reference potential for digital inputs
0, 2, 4, 6
34 DI COM2 Reference potential for digital inputs
1, 3, 5, 7
Digital inputs (DI) - Fail-safe
(formed from two standard inputs using the appropriate parameter setting)
16, 17 F-DI0 Fail-safe digital inputs, 2 channels (redundant),
freely programmable (isolated) 5.5 mA/24 V
The following are only available for CU240E2 F, CU240E2 DPF and CU240E2 PNF
5, 6 F-DI0 Fail-safe digital inputs, 2 channels (redundant),
freely programmable (isolated) 5.5 mA/24 V
7, 8 F-DI1 Fail-safe digital inputs, 2 channels (redundant),
freely programmable (isolated) 5.5 mA/24 V
16, 17 F-DI2 Fail-safe digital inputs, 2 channels (redundant),
freely programmable (isolated) 5.5 mA/24 V
Digital outputs (DO)
18 DO0, NC Relay output DO0
NC contact (0.5 A, 30 V DC)
19 DO0, NO Relay output DO0
NO contact (0.5 A, 30 V DC)
20 DO0, COM Relay output DO0
Common contact (0.5 A, 30 V DC)
21 DO1+ Transistor output DO1
Positive (0.5 A, 30 V DC)
22 DO1- Transistor output DO1
Negative (0.5 A, 30 V DC)
23 DO2, NC Relay output DO2
NC contact (0.5 A, 30 V DC)
24 DO2, NO Relay output DO2
NO contact (0.5 A, 30 V DC)
25 DO2, COM Relay output DO2
Common contact (0.5 A, 30 V DC)
Analog inputs (AI)
3 AI0+ Differential input, switchable between current, voltage
Value range: 0 ... 10 V, -10 ... +10 V, 0/2 ... 10 V, 0/4 ... 20 mA
4 AI0-
10 AI1+ Differential input, switchable between current, voltage
Value range: 0 ... 10 V, -10 ... +10 V, 0/2 ... 10 V, 0/4 ... 20 mA
11 AI1-
Analog outputs (AO)
12 AO0+ Non-isolated output
Freely programmable
Value range: 0 ... 10 V; 0/4 ... 20 mA
13 GND Reference potential of the AO0/internal electronics ground
26 AO1+ Non-isolated output
Freely programmable
Value range: 0 ... 10 V; 0/4 ... 20 mA
27 GND Reference potential of the AO1/internal electronics ground
PTC/KTY interface
14 T1 MOTOR Positive input for motor temperature sensor
Type: PTC, Pt1000, KTY, bimetal
15 T2 MOTOR Negative input for motor temperature sensor
Power supply
9 +24 V OUT Power supply output
24 V DC, max. 100 mA
28 GND Reference potential of the power supply/internal electronics ground
1 +10 V OUT Power supply output
10 V DC ±0.5 V, max. 10 mA
2 GND Reference potential of the power supply/internal electronics ground
31 +24 V IN Power supply input
20.4 ... 28.8 V DC, max. 1500 mA
32 GND IN Reference potential of the power supply input
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control
Shenzhen Aimiqu Technology Co., Ltd is a high-tech enterprise integrating industrial control product sales, automation engineering design, development and transformation. There are reliable teams with our company, for a variety of industries automation process control needs, to provide reliable, efficient services and automation overall solution.
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control

Shenzhen Aimiqu Technology Co., Ltd established in March 2016, the business scope including general management project is automation equipment accessories, instruments and meters, valves, switches, electronic semiconductor, electronic products, digital products, electronic components, communications products, computer software and hardware, security equipment, energy conservation and environmental protection products, intelligent household products; Operating electronic commerce; Domestic trade, import and export of goods and technology. Electrical automation import and export trade for the main business.

 Since its establishment, Aimiqu has been providing industrial automation services, providing customers with high-quality products and automation solutions. In the long-term business process, Emicic has established good partnerships with well-known international manufacturers .

New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control
  At the same time,Aimiqu attaches great importance to product research and development, invested a lot of funds, independent production and development of electrical equipment such as power distribution cabinet and put into use. For customers in product performance testing, automated production lines, electronic equipment, wire and cable, and other aspects of energy saving equipment reform and development, design, transform the multitude of automation equipment and automation control system, and provide a reliable and professional support, and pre-sale, sale and after-sale services - dragon, by the customer the consistent high praise.
New 6SL3244-0bb12-1PA1 Electrical Sinamics G120 Control

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now