• Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer
  • Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer
  • Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer
  • Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer
  • Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer
  • Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer

Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer

After-sales Service: 1 Year
Warranty: 1 Year
Power Supply: AC220V ±15% 50Hz±2Hz
Environment Temperature: -30~+60ºC
Environment Humidity: ≤90%Rh
Charging Voltage: 85VAC~265VAC 50Hz /60Hz
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Hubei, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 10 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (25)

Basic Info.

Model NO.
HDSF-503
Transport Package
Wooden Carton
Trademark
HD Power
Origin
Made in China
HS Code
9031809090

Product Description

General Information

HDSF-503 SF6 Gas Analyzer is a comprehensive three-in-one analyzer used to measure SF6 gas humidity (dew point), SF6 gas purity and SF6 gas decomposition products , which can detect three test data by one test to improve the work efficiency.

Features
  1. Rugged detection components
  2. Multiple measurement methods complied to different measurement requirement .
  3. Built-in gas filter and pressure regulating valve
  4. Big LCD display and easy operation
  5. Simultaneously display of all data
  6. Large capacity of data storage
  7. High sensitivity and good stability
  8. Small size, easy to carry
Specifications

1)Main data
SF6 Dew point
1.Measurement range: -80ºC~+20ºC(Supports parameters such as ppmv);
2. Accuracy: 20ºC~-30ºC (not including -30ºC), not more than the dew point temperature ±2.0ºC;
               -30ºC~-50ºC (excluding -50ºC), not more than the dew point temperature ±2.0ºC;
               -50ºC~-80ºC, not more than the dew point temperature ±3.0ºC;
3. Flow: 0.5~0.9 L/min

SF6 Purity
1.. Measurement range: 0~100%SF6(weight ratio);
2.Accuracy: ±0.5%;
3.Response time: 30s;

SF6 decomposition gas
1. Accuracy: SO2 ≤20μL/L, error≤0.5μL/L;
                     SO2>20μL/L, error≤±5%;
                     H2S≤25μL/L, error≤0.5μL/L;
                     H2S>25μL/L, error≤±5%;
                    CO ≤50μL/L, error≤±2μL/L;
                    CO>50μL/L, error≤±4%;
2. Flow: 0.2~0.4L/min
3. Response time: 10~15s.
 
2) Other parameter
Inlet gas pressure: ≤1.0Mpa;
Environment temperature: -30~+60ºC;
Environment humidity: ≤90%RH ;
Charging voltage: 85VAC~265VAC 50Hz /60Hz;
Operation time: continuously for more than several hours;
Storage capacity: 60 sets;
Operation mode: touch key input;
Communication interface: USB
Printing: thermal printer.
Alarm:sound-light alarm, self-set the alarm parameter

Main Parameter
SF6 Dew point Measurement Range  -80ºC~+20ºC(Supports parameters such as ppmv)
Accuracy 20ºC~-30ºC (not including -30ºC), not more than the dew point temperature ±2.0ºC;
-30ºC~-50ºC (excluding -50ºC), not more than the dew point temperature ±2.0ºC;
-50ºC~-80ºC, not more than the dew point temperature ±3.0ºC;
Flow 0.5~0.9 L/min
SF6 Purity Measurement Range 0~100%SF6(weight ratio)
Accuracy ±0.5%
Response Time  30s
SF6 decomposition gas Accuracy: SO2 ≤20μL/L, error≤0.5μL/L;
SO2>20μL/L, error≤±5%;
H2S≤25μL/L, error≤0.5μL/L;
H2S>25μL/L, error≤±5%;
Flow 0.2~0.4L/min
Response Time 10~15s

Other Parameter
Inlet gas pressure ≤1.0Mpa
Environment temperature  -30~+60ºC
Environment humidity ≤90%RH
Charging voltage 85VAC~265VAC 50Hz /60Hz
Operation time continuously for more than several hours
Storage capacity 60 sets
Operation mode touch key input
Communication interface USB
Print thermal printer.
Alarm sound-light alarm, self-set the alarm parameter

Multi-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas AnalyzerMulti-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas AnalyzerMulti-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas AnalyzerMulti-Functional Sf6 Gas Comprehensive Tester Sf6 Gas Dew Point Ppm Tester Purity Decomposition Sf6 Gas Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001