Medical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse Oximeter

Certification: CE
Trademark: SD
Origin: China
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
SD series
HS Code
9018199000
Production Capacity
50000units/Week

Product Description

Medical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse Oximeter

Performance SD-50DL1 SD-50DL2 SD-50D1 SD-50D2
Display Mode LED display

Color  display

Power Supply 1.5V (AAA size) alkaline batteries * 2  
Power Consumption
less than 25mA
less than 30mA less than 80 mA
Dimension 61(L) mm * 36(W) mm * 32(H) mm 60(L) * 30.5(W) * 32.5 (H) mm 61(L) * 36(W) * 32(H) mm
60(L) * 30.5(W) * 32.5 (H) mm
Weight About 60g (with the batteries) About 50g (with the batteries)) About 60g (with the batteries) About 50g (with the batteries)

Main Performance
1) Display Mode: 0.96" Dual-color display(blue and yellow)
2) SpO2 Measuring Range: 0% ~ 100%,(the resolution is 1%).
Accuracy: 70% ~ 100%: ±2% ,Below 70% unspecified.
3) PR Measuring Range: 30 bpm ~ 250 bpm, (the resolution is 1 bpm)
Accuracy: ±2 bpm or ±2% (select larger)
4) PI Measuring Range: 0 %~ 20%
Accuracy: When the PI measure range is 1%~ 20%,the permission of absolute error is ±1%
When the PI measure range is 0%~0.9%,the permission of absolute error is ±0.2%
5) Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown
correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%,
pulse rate error is ±2 bpm or ±2% (select larger).
6) Resistance to surrounding light: The deviation between the
value measured in the condition of man-made light or indoor
natural light and that of darkroom is less than±1%
7) Power Consumption: less than 80 mA
8) Voltage: DC 2.6V -3.6 V
9) Power Supply:1.5 V (AAA size) alkaline batteries x 2
10) Safety Type:Interior Battery, BF Type

Medical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse OximeterMedical Equipment Hospital Home Care Usecolor Display Blood Fingertip Pulse Oximeter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485, FSC