• Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
  • Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
  • Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
  • Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
  • Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
  • Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

Usage: Hydrogen, Nitrogen
Purpose: Control Gas
Parts: Burner Controller
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Small
Samples:
US$ 82/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
LME41.054C2
Condition
New
Certification
ISO, CE
Name
Burner Controller
Model
Lme41.054c2
Brand
Siemens
Power Supply
230V 50/60 Hz.
Power Consumption
Approx. AC 3.5 Va
Ambient Temperature
-20...+60 °c
Weight
Less 1kg
Color
Black
Primary Fuse (External)
Max. 10 a (Slow)
Humidity
< 95 % R.H
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Transport Package
Carton
Specification
11*8*7cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000

Product Description

LME41.054C2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

Product Description

Application:
LME...for monitoring and control of single-stage or double-stage gas burners during start-up and intermittent operation. flame monitoring Pass ionization bar or flame detector QRA and auxiliary equipment AGQ3 or use blue flame detector QRC. according to the shell Dimensions, LME... Same burner controller as LGB and LMG

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
Less 1kg
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
Germany
Brand Name
Siemens
Type
Gas Burner
Product name
LME41.054C2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Brand
Siemens
Model
LME41.054C2
Color
Black
Power supply
230V 50/60 Hz.
Power consumption approx. AC 3.5 VA
Ambient Temperature
-20...+60 °C
Humidity
< 95 % r.h.
Degree of protection  IP 40, with the exception of  the connection area
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

LME41.054C2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Features:
Combustion control according to EN 298 Strong exhaust burner according to EN 676 Undervoltage detection Monitor air pressure during startup and operation with an air pressure switch Convenient remote reset Various colors display information on error status and operating status A limited number of repetitions Precise control sequence due to the use of digital signal processing After 24 hours of continuous operation, it must be stopped once

 
 
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

Electrical connection of flame detectors:

It is important to achieve practically disturbance- and loss-free signal transmission:
1.Never run the detector cable together with other cables
- Line capacitance reduces the magnitude of the flame signal
- Use a separate cable
2. Observe the permissible lengths of the flame detector cables (see Data Sheets
N7714 (QRB...) and N7716 (QRC...))
3.Earth the burner in compliance with the relevant regulations; earthing the boiler
alone does not sufficeent.

 

Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Installation Precautions:
1.The controller unit and other cables must be installed separately from the high voltage ignition cables.
2.Do not confuse phase and neutral.
Install switches, fuses, grounding, etc. in accordance with local regulations.
3.Connection diagram showing the application of a grounded neutral wire to the burner control. Ionization current monitoring in the network without connection In the case of a ground conductor, terminal 2 must be routed through an RC unit (Type: ARC 4 668 9066 0). Connect the ground wire. Local regulations must be followed (e.g. protection against electric shock) Because the mains voltage of AC 230 V / 50 4.Hz produces a current leakage of up to 2.7 mA.
Verify that the maximum amount of current allowed by the terminal is not exceeded.
5.Do not supply an external mains voltage to the control output of the combustion controller, when the test unit controls the combustion controller (fuel valve, etc.), LME do not connect.
In the absence of a fan, the AGK25 must be connected to terminal 3, otherwise the burner will not start reliably.
6.For safety, connect the neutral conductor to terminal 2. As shown below, the burner components (fan, ignition compressor, air valve) must be connected to the neutral conductor. The connection between the neutral conductor and terminal 2 is at the control unit The bottom is pre-wired.
 


Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

 

Recommend Products

 

Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
 
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

 

LME41.054C2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller
Lme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System ControllerLme41.054c2 Combustion Safety Program Industrial Gas Control Burner Combustion System Controller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now