Breaking Capacity: | Low Voltage Circuit Breakers |
---|---|
Operation: | Manual Type |
Speed: | Normal Type Circuit Breaker |
Arc-extinguishing Medium: | Oil-immersed Type |
Installation: | Fixed |
Poles Number: | 1 |
Customization: |
---|
Suppliers with verified business licenses
Poles | 1P+N (18mm) |
Rated current In | 10-40A |
Rated voltage Un (V) | 240 |
Residual current off-time | ≤0.1S |
Rated frequency | 50Hz |
Rated residual operation current | 30mA |
Ambient temperature | -10°C ~ +60°C |
Fiducial temperature | 30ºC |
Rated residual non-operating current (mA) | 0.5 |
EMC | 4000 |
Breaking capacity | 6KA |
Rated residual switching and breaking capacity | 500A |
Short circuit capacity | 4KA |
Mechanical life | 4000 |
Protection level | IP20 |
Tightening torque | 1.2N*m |
Residual current action breaking time | ||||||
In(A) | In(A) | Breaking time when the residual current is equal to the following value(s) | ||||
In | 2In | 5In | 5A,10A,20A,50A,100A,200A | It | ||
6~40A | 0.03,0.1,0.3 | 0.1 | 0.05 | 0.04 | 0.04 | 0.04 |
Note: The tests of 5A, 10A, 20A, 50A, 100A, and 200A do not test the current value greater than the lower limit of the instantaneous tripping range of the current; The instantaneous tripping of the over current at IΔt is equal to the type B and type C Test the current at the lower limit of the range. | ||||||
Improvements to Australia's differences in RCBO standards (product selling points) | |
In and out line reverse connection and zero fire line reverse connection protection | Add a break point device inside the product; stop powering the circuit board after the handle is disconnected, ensure the damage of electronic components, and ensure the reliability of the product; |
Over-current protection tripping characteristics (reference temperature 30 ° C) | ||||||
TEST | TYPE | TEST CURRENT | Starting state | Trip or no trip time limit | expected results | REMARK |
a | B,C | 1.13In | Cold state | t≤1h | No Tripping | |
b | B,C | 1.45In | Followed by a test | t<1h | Tripping | The current rises steadily within 5s |
c | B,C | 2.55In | Cold state | 1s |
Tripping | |
1s32A) | ||||||
d | B | 3In | Cold state | t≤0.1S | No Tripping | |
5In | t<0.1S | Tripping | ||||
e | C | 5In | t≤0.1S | No Tripping | ||
10In | t<0.1S | Tripping |
Poles |
1P+N (18mm) |
Rated current In |
10-40A |
Rated voltage Un (V) |
240 |
Residual current off-time |
≤0.1S |
Rated frequency |
50Hz |
Rated residual operation current |
30mA |
Ambient temperature |
-10°C ~ +60°C |
Fiducial temperature |
30ºC |
Rated residual non-operating current (mA) |
0.5 |
EMC |
4000 |
Breaking capacity |
6KA |
Rated residual switching and breaking capacity |
500A |
Short circuit capacity |
4KA |
Mechanical life |
4000 |
Protection level |
IP20 |
Tightening torque |
1.2N*m |