Introduction
Diffused silicon pressure transmitter PT-ID029 selects of high-precision, high stability and high reliability diffused silicon pressure sensing element and imports of high-quality integrated circuit, it is a high precision, reliable, good stability, long service life of industrial pressure transmitter for measuring the pressure of liquid or gas, and a variety of liquids. Live remote pressure and level measurement instrumentation and converted into a standard electrical signal pressure or level. PT-ID029 pressure transmitter, because of its excellent performance,
Application
*Industrial field process pressure control
*Aerospace field
*Petrochemical industry
*Light industrial machinery
*Medical equipment
*Marine shipbuilding industry
*Water conservancy and hydropower plant
*Constant pressure water supply
*Other automation control and detection system
Technical Parameter
Basic error |
0.25%F•S. 0.5%F.S |
Measurement range |
-0.1MPa~0; 0~(10KPa~60MPa) |
Linearity |
>0.2%F•S |
Temperature drift |
<±0.025%F•S/ºC (0-50ºC ) |
Long-term stability |
≤0.02%F•S/year |
Response time |
≤10mS |
Power supply |
24VDC (or 12VDC-36VDC arbitrary constant voltage power supply) |
Output |
4~20mA(O~10mA 1~5V O~5V 0~1OV) |
Load resistance |
0~600Ω(Rz=(V-12)/0.02 V is supply voltage) when output is 0~10mA, load resistance is 0~1.2kΩ |
Pressure overload limit |
the max pressure rated 1.5 times |
Ambient temperature |
-20~ +85ºC |
Measured medium temperature |
20~ +85ºC (>85ºC can use radiating tube) |
Recommend storage temperature |
-20~ +125ºC |
Sensor interface (pressure interface) |
M20×1.5,1/2NPT or customized |
Electrical interface |
M20×1.5 |
Installation site |
unlimited |
Shell protection level |
IP65 |
Sensor interface material |
1Cr18Ni9Ti |
Sensor isolated diaphragm material |
316LSS |
Shell material |
Al. |
Weight |
550 g |
Power |
< 0.5 W |