• Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD
  • Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD
  • Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD
  • Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD
  • Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD
  • Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

Application: Dedicated VFD
Output Type: Triple
Principle of Work: Vector Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Medium Voltage Variable-Frequency Drive
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 45 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (26)
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
EM618
Link of Transformation
AC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Engineering Cabinet VFD
Brand
Sinee
Control Methods
V/F and Vector Control
Transport Package
Wooding
Trademark
SINEE
Origin
China
Production Capacity
400000sets/Year

Product Description

Gabinete de ingenieria Variadores de frecuencia variable Variadores de CA dedicados a la venta VFD
Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

•Funcionamiento estable con baja frecuencia y alto par: el par nominal de 0,5 Hz/150 % se genera suavemente, lo que garantiza un arranque suave y sin problemas del molino de bolas;
•La conveniente interfaz de operación hombre-máquina (pantalla táctil) puede configurar convenientemente el tiempo de funcionamiento de múltiples segmentos y la frecuencia de funcionamiento de cada período de tiempo, y puede verificar convenientemente la información de operación de corriente y voltaje a través de la interfaz hombre-máquina;
•Excelente capacidad de limitación de corriente: asegúrese de que el gabinete de control no se dispare cuando la carga fluctúe con frecuencia;
•Amplio rango de entrada de voltaje, estabilización automática de voltaje: para garantizar que cuando el voltaje de la red cae, la salida aún pueda cumplir con los requisitos de salida de torque del equipo de elevación;
•Amplia gama de ajuste de velocidad: cumpla con los requisitos de los equipos de elevación de carga ligera de alta velocidad y de carga pesada de baja velocidad, y mejore la eficiencia de trabajo del equipo;
•La interfaz de comunicación Modubus se utiliza para verificar el estado de funcionamiento del inversor;
•Función continua de falla de energía instantánea, puede retroalimentar automáticamente la energía eléctrica para garantizar una cierta salida de torque;
•El convertidor de frecuencia y el motor están adaptados para usarse con la misma potencia y no es necesario aumentar la capacidad del convertidor de frecuencia;
Product Description

Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

Product Parameters
Steps Operation content
Installation Check the power of the special frequency conversion control cabinet for the ball mill, and install the special frequency conversion control cabinet for the ball mill as required.
Wiring of special frequency conversion control cabinet for ball mill Wiring as required
Check before power on Confirm that the input power supply is correct, the input power supply circuit has been connected to the circuit breaker; the special frequency conversion control cabinet for ball mills has been grounded; the power cord is correctly connected to the R, S and T power input terminals of the special frequency conversion control cabinet for ball mills; the motor is correctly connected to the U terminal of the special frequency conversion control cabinet for ball mills. , V, W output terminals; the control circuit wiring is correct, the external switch is in the correct position; the motor is unloaded, and the mechanical load has been disengaged from the motor
Power-on check Whether there is abnormal sound, peculiar smell, smoke, etc. in the dedicated frequency conversion control cabinet for ball mills; the power indicator light is on, the operation panel displays normal, and there is no fault alarm message; if there is any abnormality, please disconnect the power immediately for inspection
Parameter settings In the case of the initial operation of the special frequency conversion control cabinet for ball mills, repairs, or replacement of motors, please restore the parameters to the factory values before performing subsequent operations
Enter the motor nameplate parameters correctly Please enter the nameplate parameters of the driven motor correctly and check carefully, otherwise serious problems may occur during operation
Protection parameter setting of special frequency conversion control cabinet for motor and ball mill Correctly set the limit parameters, protection parameters and protection methods of the special frequency conversion control cabinet and motor for ball mills, mainly including: maximum frequency, upper limit frequency, lower limit frequency, lower limit frequency running time, fault retry control, relay fault output, etc.
Motor parameter self-identification Before selecting the vector control mode to run for the first time, the motor parameter self-identification needs to be carried out to obtain the accurate electrical parameters of the controlled motor. If the motor load cannot be disengaged, you can select the motor static self-identification; if the motor is still rotating, do not perform the motor parameter self-identification operation
Set control parameters General parameters According to the working conditions of the drive system, correctly set the direction of rotation, forward and reverse control, acceleration and deceleration time, drive mode, start and stop mode, input mode, etc.
V/F Control Set V/F curve, torque boost, slip compensation, AVR function and other parameters according to load requirements
Vector control Set regulator parameters and torque control and setting parameters according to load conditions.
No-load test run inspection The motor is empty, use the keyboard or control terminals to start the special frequency conversion control cabinet for the ball mill to run, check and confirm the running status of the drive system;
Motor: stable operation, normal rotation, correct steering, normal acceleration and deceleration process, no abnormal vibration and noise, no abnormal smell;
Special frequency conversion control cabinet for ball mill: the operation panel displays normal data, the fan operates normally, the relay operates normally, no vibration, no peculiar smell. If there is any abnormal situation, immediately shut down and check the power
Load test run inspection After the no-load inspection is normal, connect the drive system load
Start the special frequency conversion control cabinet for the ball mill through the terminal or keyboard, gradually increase the load, and observe whether the system is running normally under the load;
If there is any abnormal situation, immediately shut down and check
Normal Operation Basic operation The special frequency conversion control cabinet for the ball mill can perform normal start, run, stop, forward and reverse and other basic operating functions. If there is any abnormality, please check whether the input and start-stop function codes are set correctly
Advanced operation Speed control Program running Set the program to run the code. After setting, it can drive the system to run in a single cycle or repeatedly. If there is any exception, please check the program running code
PID Running Users can set the PID process control channel and PID regulator parameters according to the requirements of the drive system to realize the control of industrial processes.
Torque control The output torque of the motor can be controlled according to the input torque command value
Performance settings Speed tracking When starting, the special frequency conversion control cabinet for the ball mill will automatically detect the current rotation of the motor, so as to smoothly cut into the operation and reduce the start-up impact
S curve acceleration and deceleration It is mostly used in drag systems with relatively large inertia and occasions sensitive to acceleration to reduce mechanical shock and avoid system oscillation.
DC braking Before starting or when stopping, direct current can be applied to the rotating motor to generate braking torque, so that the motor can stop rotating quickly
Special terminal control Provide multiple programmable input and output ports, which can be used in combination with external controllers to solve various applications
Installation Instructions

Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

Model W W1 H H1 H2 H3 D D1 D2 d Gravity Center Height
EM618-185/XXX-X-XXXX 800 756 2145 2055 2000 1800 650 390 375 13 920
EM618-200/XXX-X-XXXX
EM618-220/XXX-X-XXXX
EM618-250/XXX-X-XXXX 800 756 2145 2055 2000 1800 650 390 375 13 920
EM618-280/XXX-X-XXXX
EM618-315/XXX-X-XXXX 800 756 2145 2055 2000 1800 650 390 375 13 920
EM618-355/XXX-X-XXXX
EM618-400/XXX-X-XXXX 800 756 2145 2055 2000 1800 700 440 400 13 920
Company Profile

 

Gabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFDGabinete De Ingenieria Variadores De Frecuencia Variable Variadores De Ca Dedicados a La Venta VFD

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
95
Year of Establishment
2003-04-03