Type: | Filter Dryer |
---|---|
Material: | Glass-Lined |
Capacity: | 100L -6300L |
Structure: | Flanged Type |
Pressure: | vacuum |
Agitator Model: | Combined Agitator |
Customization: |
---|
Suppliers with verified business licenses
name of ordered equipment | Glass lined agitation filter dryer | |
Sr. | ITEM | SPEC. |
1 | Main Design Data | Non- pressure, working temperature @ 90 C degree |
2 | Type | lid flange fixed vessel |
3 | Design code | Designed and manufactured as per GB150 Standard |
4 | Material | Carbon steel |
5 | Vessel Lining | Acid-resistant blue glass lined, thickness 1mm-2.0mm |
6 | Reducer | Helical gear box with Flame Proof Motor/reducer, |
7 | Main hole lifting | spring loaded (quick opening manhole) |
8 | PTFE gaskets | Non-asbestos with SS corrugation gasket enveloped PTFE |
9 | Clamps | Clamps of forged and galvanized with hanging protection ring |
10 | Agitator | drawing stickle type agitator like your present one, 14-130 RPM consistent speed or variable speed |
11 | Flush valve | Glass lined manual flush bottom valve with PTFE seat |
12 | Hydraulic cylinder | |
13 | Seal | MECHANICLA SEAL |
14 | discharge & dia. Of its nozzle |
powder unloading hole- 200 mm below sided. manual operation discharge valve |
15 | filter plate & filter cloth | cotton cloth filter cloth, 30 mm thickness HDPE filter plate 200-3000kgs or more weight |
16 | Packaging | Iron pedestal, suitable for inland or marine transportation, Split flanges are provided for all glass lined nozzles, and GL nozzles are protected with blind flanges. |
Inapplication materials and operating conditions: | Hydrofluoric acid & media which containing fluoride ions with all concentration and temperature; Phosphoric acid with concentration is over than 30% with temperature is higher than 180°C; Alkaline which PH value more than 12 with temperature higher than 80°C; When the temperature changes drastically during glass lined equipment working, the excessive thermal stress will cause the lined glass damage of the equipment. Therefore, the temperature should be raised or lowered slowly during equipment operating.
Prohibit start the agitator during the blade buried in the wet filter cake, and should be lifted to the surface of the filter cake to start agitator;
Prohibit KNOCK/HIT onto the vessel body of equipment;
Prohibit weld components onto glass lined equipment interior or exterior;
Avoid freezing of the interior media and over-pressurization of the vessel;
Prohibit use high-pressure cleaning exceeds 137 bar (2000 psi) or if the water jet is less than 30cm (12 inches) from the vessel wall, glass damage can occur. Additionally, abrasive particles mixed with the water can contribute to hydro blast damage as can water sprayed on a specific area for a prolonged period of time and contact to repairs such as patches or plugs.
Prohibit use washing liquid that can react with the feed material. |
ANFD (Agitated Nutsche Filter Dryer) is special designed for liquid-solid filter & seperate: 1/ To achieve dynamic filtration of the slurry with agitating under pressure; 2/ Injected the cleaning liquid by spray ball, stirred and mixed the filter cake and the cleaning liquid for fully washing; 3/ To dehydrate and smooth the filter cake by aigitating to ensure good washing results; 4/ Drop down the agitate to scrape and loose the filter cake for drying under the vacuum by jacket heating; 5/ Stop the agitate and sampling online, if the sample is qualified, break the vacuum, and discharge the cooling and dry material through the special side discharge valve by agitate pushing. |
|