• Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
  • Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
  • Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
  • Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
  • Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
  • Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF

Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF

Disposable: Disposable
Certification: CE, ISO, ISO13485 ISO9001
Material: Pes PVDF Ca Nylon GF
PCS/CS: 12/24
Trademark: Biologix
Origin: China
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
09-
Production Capacity
200 Cases/Week

Product Description

Extreme-low rentention Excellent Thoughput Vacuum Filtration units PES PVDF CA Nylon GF
 
Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF

Features
 
Single Use and Gamma Ray pre-sterilized
Sterile graded 0.22μm membrane: LRV>7 for Brevundimonas diminuta, ATCC19146.
Biosafety: Meet USP<87>, USP<88>
Non-pyrogenic, Nuclease-Free, low extractables and surfactant-free ensures purity of filtrate.
Extreme-low Protein Binding <1.5% (PES)
Excellent Thoughput, for faster filltration and more process volume.
GL45 threads accepts commonly used bottle style.
Ergonomic design for convenient use and stable filtration.
Glass fiber pre-filter is available.

 
Ordering Information
Cat # Description Unit
09-PES2250 Vacuum filtration unit, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml.  12
09-PES2250F Vacuum filtration unit-funnel, membrane: PES, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml.  24
09-CA2250 Vacuum filtration unit-funnel, membrane: CA, pore size: 0.22μm, diameter:90mm, funnel volume: 500ml, receiver volume: 500ml.    12
08-PES3322S Membrane: PES, pore size: 0.22μm, diameter:33mm. Double luer lock.  Individually packed. 24
 

Extreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GFExtreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GFExtreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GFExtreme-Low Rentention Excellent Thoughput Vacuum Filtration Units Pes PVDF Ca Nylon GF
1.What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2.What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3.What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc. 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, GMP