• Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
  • Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
  • Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
  • Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
  • Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
  • Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

Transport Package: Ctns(OEM)
Specification: CUSTOMIZED
Trademark: CBMTECH
Origin: Ningbo, China
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Gas Alarm System
HS Code
8419601900
Production Capacity
200sets/Month

Product Description

Basic Info.

Packing Export Standard Packing Gas Monitor Online/APP Remote
Function Hospital Medical Gas Supply Service Assign Engineer for Onsite Instruction
Transport Package Wooden Case Trademark CBMT
Origin Ningbo China    
Production Capacity 200 Set    
 

Product Description

 

1. Meet the standards of GB50751-2012 Technical Specification for Medical GasEngineering;
2.Optional 1-7 gas control which could switch the gas on and off in the ward integrally;
3.With oxygen standby interfaces: oxygen cylinder can be connected to conduct emergency treatment in the area in case of failure of oxygen station.
4.User-friendly design: the operator can observe the gas gauge reading and switch stateof valve through transparent window directly,
5.Arc design of the box body, the gas pipes and pipe fittings are made of degreasedcopper material, with high aesthetic appearance.

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
 

Medical gas four safety principles:

Continuous gas supply Sufficient flow and pressure Gas identification Gas Quality

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

Medical Gas Supply System Pipelines
 

Pipe Material

 

The main oxygen pipeline and the branch pipeline into the room are used of defatted purple copper tube or stainless steel tube. The pipeline inside of bed head unit is using degreased copper pipe.

 

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
Pipe Setting

 

The gas riser pipe is designed in the pipeline well. Pipes should be piped when crossing the wall. The pipes installation should be neat and beautiful.

 

Pipe Connection

 

Pipe system using welded connection. Metal seals throughout the pipe system connection Horizontal pipe and branch pipe of bed head unit should be with maintenance valve

 

Pipe Grounding

 

Medical gas pipelines in medical rooms should be equipotential grounded; mainfold/pipelines etc should be anti-static grounded; Independent grounding resistance should less than 10Ω;

 

Pipeline Leakage Rate

 

Leakage test of medical gas pipelines when no terminal components are connected, the hourly leakage rate should not exceed 0.05%. According to Chinese standard GB50751-2012


Medical Gas Supply System Fittings 
Zone Valve Box
Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box
 Gas Regulator Box
Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 


Monitoring alarm box
Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

 

1,Used to control the on and off of medical gases in the area;

2,1~6 channels of medical gas can be controlled according to user requirements;

3,Silver and copper welding to prevent leakage;

4,Transparent window for easy operation and maintenance;

5,Each gas is marked with a national standard color for easy identification.

1,Used to provide a pressure-stable source of gas for the clinic;

2,With dual circuit design, it can be maintained without stopping the gas;

3,Use a large flow reducer to ensure pressure stability;

4,Emergency door lock device to close the valve in an emergency;

5,Transparent window for easy operation and maintenance;

 

1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm;

2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history;

3,intelligent monitoring, with remote data transfer function;

 

 

Medical Gas Supply System Gas Management

The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.
 

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

 

Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

 

 

Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

 

 

Fault early warning: abnormal data analysis and trend analysis.

Emergency Calling Hospital Gas Alarm System Medical Gas Area Alarm Master Alarm for Zone Valve Box

 

 
Warranty
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, ETR shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
FAQ
1. who are we?
We are based in Zhejiang, China, start from 2021,sell to South America(25.00%),Southeast Asia(25.00%),Africa(20.00%),Central America(10.00%),North America(5.00%),South Asia(5.00%). There are total about 11-50 people in our office.

2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
Medical Oxygen Regulators,Oxygen Flowmeters,Oxygen Humidifiers,Oxygen Cylinders,Medical Gas Termainals

4. why should you buy from us not from other suppliers?
Equipped with too much advantages of exporting extensive variety of products serving the control,storage and transmission of high pressure gases to the medical, industrial welding,fire protection & life safety markets,and etc....

5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,DDP,DDU,Express Delivery;
Accepted Payment Currency:USD,EUR,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,MoneyGram,PayPal,Western Union,Cash;
Language Spoken:English,Chinese,Spanish,Arabic,French,Russian

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now