• Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
  • Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
  • Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
  • Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
  • Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
  • Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester

Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester

After-sales Service: 1 Year
Function: Storage
Display: Digital
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester pictures & photos
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
US $1,500-2,550 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Detailed Photos
Overview

Basic Info.

Model NO.
VS-2088
Type
Resistance Tester
Environment
High and Low Temperature
Warranty
With Warranty
Power Source
DC 100V-300V
Weight
0-10Kg
Installation
Direct Connected
Customized
Customized
Output Voltage
30kv ~ 90kv
Output Frequency
0.1Hz, 0.05Hz, 0.02Hz
High Test Capacity
5.5μf
Measuring Length Range
Over-Current Protection.
Measuring Method
Low-Voltage Pulse Method, Flash Current Method, Mu
Blind Spots
0 ~ 5m or No Blind Spots
Certification
CE; EMC; LVD; ISO;
Standby Time
Can Be Used Continuously for About 6 Hours
Control Unit Weight
7kg
Transport Package
Carton Box Wooden Case
Specification
Customized
Trademark
WESHINE
Origin
Hebei China
HS Code
9004901000
Production Capacity
2000

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 50.00cm
Package Gross Weight
50.000kg

Product Description

What should you do when there are cable faults?
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
Cable fault location is required anywhere where the fault cannot be seen, this is a multi-step process that must be performed as safely and as quickly as possible because customers will be without power.

Step 1 - Cable Isolation & Safety Procedures: A cable fault is nearly always a permanent fault. This means that the cable in question will be in a condition where the protection devices at one or both ends of the cable will have tripped, leaving the cable isolated but NOT earthed (grounded). The first task is for the Authorised Person for the site to make the cable safe by isolating and then earthing (grounding) one or both ends preferably. Only after the appropriate procedures have been carried out can any testing personnel be allowed to approach the cable and prepare for testing.

Step 2 - Cable Identification: Where multiple cables exist, cable identification testing will identify the correct cable to work on. Clear identification before a cable is cut is intrinsic to safe maintenance work. Any mistakes here can be fatal, and may cause much longer outages for the connected customers

Step 3 - Cable tracing: When an underground cable is first laid it rarely runs in a straight line, but rather meanders in depth and direction. Cable tracing is done to determine that the route of the cable is following the expected path.

Step 4 - Fault identification: The first major procedure is to determine the phase on which the fault has occurred, and if it is of low or high resistance. This test determines the correct technique and equipment to diagnose the fault. Typically, if the fault is found to be below 100 Ohms, a low voltage pulse (e.g., 40 V) from a TDR (time domain reflectometer) can be used. If the fault is a higher resistance (> 100 Ohm), a low voltage pulse will likely not see it. For these types of faults, an Impulse generator (shock discharge) will be necessary.

Step 5 - Fault prelocation: A reliable and precise pre-location method is necessary to locate a cable fault quickly and efficiently. Good pre-location can determine the fault position to within a few percent of the cable length and will reduce pinpointing time to a few minutes. Remember: a). If it is a low resistance fault, pre-location was likely to be the only means necessary for location. b). For high resistance faults, ARM (arc reflection) or ICE (impulse current) techniques on an SWG (surge wave generator) should be used. Alternatively, the decay method with an HV DC tester (bridge), can be used for pre-location.

Step 6 - Pinpointing: The aforementioned test methods will get the operator with 5% distance of the fault, acoustic pinpointing techniques must be employed to narrow the margin of error to 0.1%. In most cases, shock discharge generators are used for pinpointing in conjunction with acoustic methods. The discharge creates a loud noise, which is pinpointed precisely using an acoustic pinpointing device. This device evaluates the time difference between the acoustic signal (speed of sound) and the electromagnetic (nearly the speed of light) impulse of the shock discharge. When the shortest time difference is indicated, the exact fault location is revealed.

Step 7 - Re-energisation of the cable: Once all testing and repairs are completed, the Safety/Testing Documentation is cancelled. the cable is then handed back to the appropriate operators to reinstate the cable and re-energise the loads on the newly repaired cable.

Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester

Detailed Photos


Electricity networks have had to become more flexible, reacting more quickly to the changes and needs of higher performance. This demand for flexibility is especially true where multiple generation sources occur, such as the intermittent power from renewables like solar and wind energy. While modern SMART grid technology can quickly identify faults in sub-station and generating units, cable faults can still occur anywhere on the network. Quickly locating a cable fault for repair is the top priority for avoiding lengthy restoration times. In the first place, this will be especially impactful on electrical utility reliability indices. These indices include SAIDI, the System Average Interruption Duration Index, which measures the total duration of an interruption for the average customer during a certain time period, and SAIFI, the System Average Interruption Frequency Index, which is found by dividing the total number of customers interrupted by the total number of customers served.
 
PRODUCT INFORMATION
Product Name
Split-type Cable Fault Location System
Model Number
VS-2088
Certificates
CE; EMC; LVD; ISO;
Measuring Distance
60 km
Blind Area
<1 m
Measuring Method
Low-voltage pulse method, flash current method, multiple pulse method.
Product Function
Locate cable faults below 35 kV.
Typical Application
Power cable, street lamp cable, airport signal cable, railway communication control cable...


Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
Company Profile:
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator TesterElectrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester pictures & photos
Electrical Universal Cable Tester TDR Underground High Voltage Pinpoint HV Portable TDR Cable Fault Locator Tester
US $1,500-2,550 / Piece
Min. Order: 1 Piece
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
44
Year of Establishment
2013-09-17