• Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
  • Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
  • Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
  • Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
  • Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
  • Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304

Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304

After-sales Service: Online
Warranty: 1 Year
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Display: Digital
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
EED2005TG
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Discharge Current Rise Time
0.6-1ns
Voltage Variation Range
0% ~ 120%
Test Time
1~9999s
Power
300W
Transport Package
Plywood Cases
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

EED2005TG Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
Product introduction:

EED2005TG is a multi-functional integrated interference tester introduced by Prima Electronics in 2005, which includes three test functions: electrostatic discharge, electric fast transient pulse group and voltage drop. Products conform to IEC61000-4-2, 4, 11 and GB/T17626.2, 4, 11 and other standards.

EED2005TG Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
Product features:

 
Ø Electrostatic, pulse group and frequency drop three in one, more cost-effective;
 
Ø 7.0 color touch screen display, intelligent control, stable and reliable performance;
 
Ø Built-in national standard test grade, easy to operate;
 
Ø Built-in intelligent coupling/decoupling network for safer test;
 
Ø Built-in RS232/RJ45 communication interface, optional measurement and control software for remote control;


EED2005TG Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304
Parameters
Model EED2005TG
Silence
 
electricity
output voltage 0.2~± 20kV(±5%)
Voltage holdup time ≥5s
Output polarity
Positive, negative, first positive then negative, first negative then positive
Energy storage capacitance
150pF (standard) Other specifications can be selected according to the situation
Discharge resistor
330Ω (standard) Other specifications can be selected according to the situation
Discharge current rise time 0.6 ~ 1ns
working form  The discharge interval can be set between 0.05 and 99.99s to meet various operation modes, such as 20PPS discharge; When the setting value is less than 0.05s, it is a single discharge
Discharge frequency setting 1 ~ 9999  Or infinite times
Discharge modes

Contact discharge/air discharge

Number of discharge

Can be preset 1-9999 times or unlimited times

trigger mode

1. Automatic 2. Manual 3. Automatic voltage gradient scan


pulse
 
blunt
 
Group
output voltage 0 .2~± 4.8KV±10%
Output polarity

Positive or negative, alternating between positive and negative

impulse frequency 1kHz~1200kHz ± 10%, continuously adjustable
internal output impedance
50 Ω
pulse width  Load characteristic impedance 50 Ω     50ns ± 30%
 Load characteristic impedance 1k Ω     35 ns~150 ns
Pulse train length The value is adjustable from 1 to 255
Pulse train period Typical 300mS (0.15 -- 9.99S adjustable, precision 0.01S)
 Coupling/decoupling network Built-in single-phase three-wire power network
AC MAX 250V  16A
DC MAX 220V  16A
test time 1~9999S

weeks
 
wave
 
fall
 
voltage variation range 0% ~ 120%
The duration of the voltage change 1-9999 semi-cycle
Switching phase setting 0 °~ 360 ° Or asynchronous resolution: 1°
The number of repetitions of voltage changes 1-60000 time
Interval period of voltage change 1-9999 semi-cycle
manner of working Automatic, internal trigger
Capacity of the device under test single phase,AC220V,10A
equipment working power supply AC220V 50/60Hz
Dimensions
238*484*590mm   
Power
300W
weight 37Kg


 
Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304Eed2005tg Combined Interference Generator Disturbance Simulator Lightning Surge Simulator ISO14304

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now