Nature of Source Flow: | Active Inverter |
---|---|
Certification: | RoHS, CE |
Output Power: | >1000W |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Model IPS
|
80248/96/192
(802) |
10348/96/192
(103) |
12396/192
(123) |
|
Rated Power
|
8KW
|
10KW
|
12KW
|
|
Peak Power(20ms)
|
8KW
|
10KW
|
12KW
|
|
Start Motor
|
24KVA
|
30KVA
|
36KVA
|
|
Battery Voltage
|
5HP
|
7HP
|
7HP
|
|
Size(L*W*Hmm)
|
540x350x695
|
|||
Packing Size(L*W*Hmm)
|
600*410*810
|
|||
N.W.(kg)
|
66
|
70
|
77
|
|
G.W.(kg)
|
77
|
81
|
88
|
|
Installation Method
|
Tower
|
|||
Input
|
DC Input Voltage Range
|
10.5-15VDC(Single battery voltage)
|
||
AC Input Voltage Range
|
92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) /
195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC) (8KW~40KW) |
|||
AC Input Frequency Range
|
45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
|
|||
Max AC charging current
|
0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power)
|
|||
AC charging method
|
Three-stage (constant current, constant voltage, floating charge)
|
|||
|
Efficiency(Battery Mode)
|
≥85%
|
||
Output Voltage(Battery Mode)
|
110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
|
|||
Output Frequency(Battery Mode)
|
50Hz±0.5 or 60Hz±0.5
|
|||
Output Wave(Battery Mode)
|
Pure Sine Wave
|
|||
Efficiency(AC Mode)
|
>99%
|
|||
Output Voltage(AC Mode)
|
Follow input
|
|||
Output Frequency(AC Mode)
|
Tracking Automatically
|
|||
Output waveform distortion
(Battery Mode) |
≤3%(Linear load)
|
|||
No load loss(Battery Mode)
|
≤1% rated power
|
|||
No load loss(AC Mode)
|
≤2% rated power( charger does not work in AC mode)
|
|||
No load loss
(Energy saving Mode) |
≤10W
|
|||
(selectable) |
VRLA Battery
|
Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
|
||
Customize battery
|
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
|||
|
Battery undervoltage alarm
|
Factory default: 11V(Single battery voltage)
|
||
Battery undervoltage protection
|
Factory default: 10.5V(Single battery voltage)
|
|||
Battery overvoltage alarm
|
Factory default: 15V(Single battery voltage)
|
|||
Battery overvoltage protection
|
Factory default: 17V(Single battery voltage)
|
|||
Battery overvoltage recovery voltage
|
Factory default: 14.5V(Single battery voltage)
|
|||
Overload power protection
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|||
Inverter output short circuit protection
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|||
Temperature protection
|
>90°C(Shut down output)
|
|||
|
A
|
Normal working condition, buzzer has no alarm sound
|
||
B
|
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
|
|||
C
|
When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
|
|||
(Optional |
Charging Mode
|
PWM or MPPT
|
||
charging current
|
PWM:(48V:120A;96V:50A/100A;192V/384V:50A / MPPT:(48V:100A/200A;96V:50A/100A;192V/384V:50A)
|
|||
PV Input Voltage Range
|
PWM: 60V-88V(48V system); 120V-176V(96V system);240V-352V(192V system)
MPPT: 60V-120V(48V system); 120V-240V(96V system);240V-360V(192V system) |
|||
Max PV Input Voltage(Voc)
(At the lowest temperature) |
PWM: 100V(48V system); 200V(96V system);400V(192V system)
MPPT: 150V(48V system); 300V(96V system);450V(192V system) |
|||
PV Array Maximum Power
|
48V system: 6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A);
96V system: 5.6KW(50A)/11.2KW(100A);192V system: 11.2KW(50A) |
|||
Standby loss
|
≤3W
|
|||
Maximum conversion efficiency
|
>95%
|
|||
Working Mode
|
Battery First/AC First/Saving Energy Mode
|
|||
Transfer Time
|
≤4ms
|
|||
Display
|
LCD
|
|||
Thermal method
|
Cooling fan in intelligent control
|
|||
Communication(Optional)
|
RS485/APP(WIFI monitoring or GPRS monitoring)
|
|||
Environment
|
Operating temperature
|
-10ºC~40ºC
|
||
Storage temperature
|
-15ºC~60ºC
|
|||
Noise
|
≤55dB
|
|||
Elevation
|
2000m(More than derating)
|
|||
Humidity
|
0%~95% ,No condensation
|
Shenzhen Shengshi Tianhe Electronic Technology Co, Ltd is a new-mode high-tech enterpriseengaged in research and development,
FAQ:
1) Q:What is the minimum order for this solar inverter?
|
A: No MOQ request,welcome to take a sample for you check quality and function, we mainly deals with wholesale deals.
|
2) Q:What payment methods your company accept?
|
A: Trade Assurance Order on alibaba, Paypal, T/T.
|
3) Q:How long for the delivery time of solar inverter
|
A: sample order 7-10days, mass production: 20-30days
|
4) Q: what is the service of your goods?
|
A: Offer a pre-production sample before mass production; and final Inspection before shipment;
|
5)Q:Why your quotation is higher than other suppliers? |
A:In domestic market, the high and low inverter brands are mixed together. There are many low-cost power inverter is actually some assembled small unlicensed workshops,crudely to reduce costs and use of substandard components for assembly, there is a very big security risk! In order to protect the pro personal and property safety, please do not covet low price, be sure to choose a reliable inverter! |
6)Q:Is the output voltage of our inverter stable ? |
A:Absolutely. Our inverter is designed with a good regulator circuit. You can even check it when measuring the true value by a multimeter. Actually the output voltage is quite stable. Here we need make a especial explanation : many customers found it is unstable when using conventional multimeter to measure voltage. We can say the operation is incorrect. Ordinary multimeter can only test pure sine waveform and calculate datas. |
7)Q:What should be noticed when installing inverter? |
A:Put the product in a place where is well ventilate,cool, dry and water-proof. Pls do not stress and do not put foreign objects into the inverter.Rember turn on the inverter before turn on the appliance. |
Suppliers with verified business licenses