Task: | Program |
---|---|
Structure: | Combination |
Signal: | Continuous |
Function: | Automatic Control |
Certification: | RoHS, ISO: 9001, CE |
Condition: | New |
Customization: |
---|
Suppliers with verified business licenses
Order Data
Product Name |
Specifications |
Order No. |
C35-01 |
CTH300-C motion control CPU, 32MB PM, 64KB data stored when power down, 55M expansion bus;1 Free port, 1 EtherCAT port, 1 EtherNET port, 1 CAN port,1 USB port.(Recommend) |
CTH3 C35-001S2 |
C36-01 |
CTH300-C motion control CPU, 32MB PM, 64KB data stored when power down, 55M expansion bus;1 Free port, 1 EtherCAT port, 1 EtherNET port, 1 CAN port,1 USB port.Support SoftMotion.(Recommend) |
CTH3 C36-001S2 |
C37-01 |
CTH300-C motion control CPU, 32MB PM, 64KB data stored when power down, 55M expansion bus;1 Free port, 1 EtherCAT port, 1 EtherNET port, 1 CAN port,1 USB port.Support SoftMotion,CNC.(Recommend) |
CTH3 C37-001S2 |
C37-02 | CTH300-C motion control CPU, 32MB PM, 120KB data stored when power down, 55M expansion bus;1 RS485 port(Modbus), 1 EtherCAT port, 1 EtherNET port, 1 CAN port,1 USB port.Support single axis motion control, interpolation, electronic gear and electronic CAM and other SoftMotion command set functions and CNC functions, support CODESYS programming platform SP11 version | CTH3 C37-002S2 |
Performance Parameters
Model No. |
C35-00 |
C36-00 |
C37-00 |
C35-01 |
C36-01 |
C37-01 |
C37-02 | ||
Physical Features |
|||||||||
Dimension(W×H×D) |
34×115×101.6 mm |
||||||||
Power consumption |
19.2W |
||||||||
Memory |
|||||||||
User program memory |
32MB |
32MB |
32MB |
32MB |
32MB |
32MB |
32MB | ||
Power down to maintain space
|
32KB |
64KB |
120KB | ||||||
Power supply features |
|||||||||
Rated input voltage |
24V DC |
||||||||
Input voltage range |
20.4V~28.8V DC |
||||||||
Input current |
0.8A |
||||||||
Reverse polarity protection |
Yes | ||||||||
Bus power supply voltage |
+5V DC |
||||||||
Bus supply current |
1.6A |
||||||||
Isolation |
Isolation between external power and system power |
||||||||
LED indicator features |
|||||||||
24V power indicator (green) |
On: 24VDC power supply is normal, off: no 24VDC power supply |
||||||||
SF indicator (red)
|
On: system failure, off: no error |
||||||||
BF indicator (red) |
On: bus failure, off: no error |
||||||||
Run indicator (green) |
On: system runs, off: the system stops |
||||||||
STOP indicator (orange) |
On: system stops; off: system runs |
||||||||
RJ45 network port indicator |
Green |
Blink: connected, off: unconnected |
|||||||
Yellow |
On: 100Mbps, off: 10Mbps |
||||||||
CAN port indicator |
Green |
-- |
Data receiving indicator |
||||||
Yellow |
-- |
Data transmission indicator |
|||||||
Real time clock |
|||||||||
Power down of maintain time |
Power down retention time approx. 112 hours (typical value) |
||||||||
Precision |
Monthly deviation <60 seconds |
||||||||
Read/set the real-time clock |
Read/set via the SETRTC directive |
||||||||
Protection function |
|||||||||
Power protection |
Power supply end provides reverse connection protection function and surge absorption function |
||||||||
Interface protection |
Communication port lightning protection |
||||||||
Extend I/O capabilities |
|||||||||
Supports INT-00 rack count of 1 CPU |
4 |
||||||||
Maximum number of modules supported per rack |
Support up to 8 modules, power, CPU, relay module is not including |
||||||||
Supports ETC-00 rack count of 1 CPU |
Supports up to 128 |
||||||||
Number of modules supported per ECT-00 |
Supports up to 8 modules |
||||||||
Isolation |
|||||||||
Power supply isolation |
Isolation between external power and system power |
||||||||
Communication isolation |
Ethernet, RS485 isolation, CAN isolation |
Model No. |
C35-00 |
C36-00 |
C37-00 |
C35-01 |
C36-01 |
C37-01 |
C37-02 |
||||||
Supports SP4 version of Codesys platform |
Supports Codesys platform SP11 version |
||||||||||||
EtherNET port |
|||||||||||||
Communication port |
1*EtherNET port |
||||||||||||
Baud rate |
10/100Mbps adaptive |
||||||||||||
Protocol type |
Codesys custom protocol, based on UDP and TCP, support Ethernet programming and Ethernet communication between CPU, support Socket free communication. |
||||||||||||
Maximum cable length per segment |
100m directly connected |
||||||||||||
Maximum number of connections to a site |
UDP supports up to 16 connections and TCP supports up to 32 connections. |
||||||||||||
DHCP feature | Support | ||||||||||||
Remote monitoring/programming | Support | ||||||||||||
Isolation | Communication port isolation | ||||||||||||
EtherCAT port |
|||||||||||||
Communication port |
1*EtherCAT port |
||||||||||||
Maximum number of site |
Each master supports up to 128 EtherCAT slave stations per master |
||||||||||||
Protocol type |
EtherCAT |
||||||||||||
Support functions |
Supports distributed clock configuration |
||||||||||||
Support startup parameter configuration |
|||||||||||||
Support for configuring PDO parameters and mappings |
|||||||||||||
Support for configuring bus cycle cycle, configuring startup check vendor ID and product ID |
|||||||||||||
Maximum cable length per segment |
100m |
||||||||||||
Baud rate |
10/100Mbps adaptive |
||||||||||||
Isolation |
Communication port isolation |
||||||||||||
RS485 port |
|||||||||||||
Communication port |
1*RS485 port |
||||||||||||
Maximum number of site |
Each network with a maximum of 1 master station and 31 slave stations |
||||||||||||
Protocol type |
Modbus master/slave protocol |
||||||||||||
Modbus Baud rate |
1200\4800\9600\19200\38400\57600\115200bps |
||||||||||||
Isolation |
Communication port isolation |
||||||||||||
CANopen port |
|||||||||||||
Communication port |
-- |
1*CAN communication master station port |
|||||||||||
Maximum number of slave sites |
Up to 32 slave stations can be connected behind one master station |
||||||||||||
Protocol type |
CANopen DS301 standard protocol |
||||||||||||
Support functions |
Support for automatically starting CANOpen Manager |
||||||||||||
Support optional slave polling |
|||||||||||||
Support to start slave stations |
|||||||||||||
Support to start slave stations |
|||||||||||||
Support synchronous production |
|||||||||||||
Support synchronous consumption |
|||||||||||||
Support heartbeat generation |
|||||||||||||
Support activation time creation |
|||||||||||||
Transmission rate(kbit/s) |
1000 |
800 |
500 |
250 |
125 |
50 |
20 |
||||||
Maximum length(m) |
25 |
50 |
100 |
250 |
500 |
1000 |
2500 |
||||||
Isolation |
Communication port isolation |
Power interface definition
4pin terminals spaced at 3.81mm apart |
Symbol |
Signal definition |
|
L+ |
+24V power |
M |
+24V power ground |
|
|
Ground |
|
-- |
-- |
USB interface definition
USB port |
No. |
Signal |
Signal definition |
1 |
V_BUS |
+5V power |
|
2 |
Data- |
Data- |
|
3 |
Data+ |
Data+ |
|
4 |
GND |
Ground |
EtherNET interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
TX+ |
Positive end of data transmission |
2 |
TX- |
Negative end of data transmission |
|
3 |
RX+ |
Positive end of data transmission |
|
4 |
TERM |
-- |
|
5 |
TERM |
-- |
|
6 |
RX- |
Negative end of data transmission |
|
7 |
TERM |
-- |
|
8 |
TERM |
-- |
|
Shell |
PE |
Shell ground |
|
Green indicator |
As an indication of EtherNET connection status |
||
Yellow indicator |
As an indication of EtherNET connection status |
CAN interface definition
RJ45 port |
No. |
Signal |
Signal definition |
1 |
CAN_H |
Positive end of data transmission | |
2 |
CAN_L |
Negative end of data transmission | |
3 |
-- |
-- |
|
4 |
-- |
-- |
|
5 |
-- |
-- |
|
6 |
-- |
-- |
|
7 |
CAN_GND |
CAN Gound |
|
8 |
-- |
-- |
|
Shell |
PE |
Shell ground | |
Green indicator |
As an indication of CAN connection status |
||
Yellow indicator |
As an indication of CAN connection status |
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart |
||
6pin terminals |
Signal |
Signal definition |
|
A0 |
PORT0 RS485 signal A |
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
|
A0 |
PORT0 RS485 signal A |
|
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
Dial switch definition
Dial switch |
Symbol |
Dial direction |
Signal definition |
RUN |
Up |
System operation |
|
STOP |
Down |
System halt |
|
Swivel 5 times in 3 seconds |
Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
DIP |
No. |
Symbol |
Signal definition |
|
1 |
Term-PORT0 |
Terminal resistance switch 1(PORT0) ON:with terminal resistance OFF:without terminal resistance
|
2 |
NC |
Reserve |
|
3 |
NC |
Reserve |
Suppliers with verified business licenses