• Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
  • Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
  • Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
  • Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
  • Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
  • Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv

Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv

Application: High-voltage
Material: Composite Polymer
Structure: Post Insulator
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv pictures & photos
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
US $5-250 / Piece
Min. Order: 5 Pieces
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Overview
  • Product Parameters
  • Product Description
  • Detailed Photos
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • Exihibition
  • FAQ
Overview

Basic Info.

Model NO.
All Type
Type
B Type Insulator
Usage
High Voltage Power Transmission, Insulation, Electrical Installation
Connection Method
Spherical Type
Size of Bearing Capacity
All Type
Certification
ISO9001
Color
Grey, Red, Customized
Brand
Line Power
Rated Voltage
11kv,33kv,45kv,66kv,110kv,138kv,220kv,Custonmized
Contract Manufacturing
OEM Service Offered
Business Type
Manufacturer, Trading Company
Creepage Distance
Customized
Transport Package
Plywood Cases, Solid Wood Cases or Carton Boxes.
Specification
Customized
Trademark
Customized
Origin
Wuhan, China
HS Code
85469000
Production Capacity
15000pieces/Month/Machine

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
10.000kg

Product Description

Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
At present, composite polymer post insulators are widely used in power grid transmission lines, accounting for about 50% of the Line's silicone rubber insulator consumption. Among them, the proportion of linear towers is higher. Almost all linear towers in heavily polluted areas use composite insulators. Composite polymeric insulators have solved the pollution flashover problem that has plagued the power grid for many years with their excellent anti-flashover performance. We can design the drawings according to the clients' requirements.
 
Product Parameters

Composite Line Post Insulator

No. Description Rated 
Voltage
 (kV)
Specified 
Mechanical 
Bending Load (kN)
Section 
Height      
 H (mm)
Minimum 
Arcing Distance
(mm)
Minimum  
Creepage Distance
L(mm)
Lightning Impulse 
Withstand Voltage 
 ≥(kV)
Power Frequency 
Withstand Voltage (kV)  
1 FPQ-11/5 11 5 265±10 180 400 105 47
2 FZSW-22/10 22 10 280±10 230 610 145 65
3 FZSW-33/12.5 33 12.5 460±10 410 1100 200 90
4 FZSW-69/22.2 69 22.2 950±15 710 2030 325 130
5 FZSW-115/17 115 17 1220±20 990 3150 540 305
6 FZSW-138/12 138 12 1514±30 1290 3820 650 385
7 FZSW-161/13 161 13 1519±30 1300 4000 650 385
8 FZSW-230/8 230 8 2250±30 1970 6270 1050 460
9 FZSW-330/7 330 7 2800±30 2500 7500 1200 600
10 FZSW-115/30 115 30 1400±30 1100 3580 550 320
11 FZSW-138/26 138 26 1500±30 1200 3650 650 350
12 FZSW-161/18 161 18 1700±30 1400 4200 750 410
13 FZSW-230/17 230 17 1850±30 1590 5016 860 465
14 FZSW-230/12.5 230 12.5 2400±30 1950 6230 1050 560
15 FZSW-330/12 330 12 3000±50 2500 7500 1300 700


Composite Station Post Insulator

No. Description Rated
Voltage
(kV)
Specified Mechanical Bending Load (kN) Section Height
H (mm)
Minimum Arcing Distance
H (mm)
Minimum Creepage DistanceL (mm) Lightning Impulse Withstand Voltag≥(kV) Power Frequency Withstand Voltage≥(kV)
1 FZSW-66/16 66 16 770±1 636 1813 325 130
2 FZSW1-110/10 110 10 1220±2.7 1084 3150 450 185
3 FZSW2-138/10 138 10 1200±2 1064 3150 450 185
4 FZSW1-110/20 110 20 1220±2.7 1044 3150 450 185
5 FZSW2-138/20 138 20 1200±2 1024 3150 450 185
6 FZSW - 252/20
(Upper & lower components)
252 20 2300±3.8 2007 6300 950 395

Composite Pin Type Insulator
No. Description Section
Height
(H mm)
Dry Arcing
Distance
(h mm)
Creepage Distance(mm) 1 min Wet Power 
Withstand Voltage (kV)
Lightning Impulse 
Withstand Voltage (kV)
 Specified Bending
Load 
≥(kN)
1 FPW1-11T16 236±5 150 390 50 100 2
2 FPW4-11T20 236±5 150 390 50 100 3.5
3  FPW - 36T20 500±5 400 1200 125 210 12.5

Notes:
1. The color can be customized.
2. Below 220kV electrical data shown for composite line post insulators without corona rings and mounted vertically. Wuhan Line Power recommends corona rings to be installed at 220kV and above.
3. Additional section lengths and creepage distances are available. Contact sales agency for details.
4. All dimensions, tolerances and tests are within allowable IEC standards or ANSI standards.
5. All dimensions are in millimeters(mm). If in inches and pounds, please specify.
6. We can design according to the end user's requirements.

 
Product Description

Raw Materials

Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
 
End Fittings Core Sheds and Housing
Hot dip galvanized cast iron or cast steel Epoxy & Glass fiber(ECR is available) HTV Silicone Rubber
Min. thickness of the galvanization: 86μm Diameter(mm): Φ38, Φ40, Φ55, Φ70, Φ90, Φ120 Color: Grey, Red
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
 
Detailed Photos
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv

 

Company Profile
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Our company with strong strength, reasonable price, good service and a number of enterprises to establish a long-term partnership. With high quality products and perfect after-sales service, we have won the consistent reputation of customers all over the country. We sincerely welcome customers from home and abroad to visit, investigate and discuss business cooperation. 

Advanced Manufacturing Equipments
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kvThe company holds the most advanced Automatic Silicone Injection Molding Machines and Voice-operated Displacement Crimping Machines which means the world's most advanced process technology level.

Sound Testing Equipment
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
The company is equipped with 1000kV Power Frequency Testing Transformer, 1800kV Impulse Voltage Generator set and 2000kN Automatic Tensile Test Machine, as well as well-equipped Physical Laboratory and Electrical Laboratory.
 
Certifications
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Standards:
IEC 61109, ISO 9001, ISO 14001, ISO 45001. We can design products in accordance with Client's Requirements.

Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kvWe have implemented advanced management and set up a strict quality management system according 1- 1509001 : 200S. All the products' quality requirements comply with IEC61109, IEC62231, G3/T19519-2004,GE/T 22079-200s, DU/T 1048-2007.DL/T810-2002 and TE/T3199.2-200g Standards, etc.
 
Packaging & Shipping

1. All composite insulators are packed in weatherproof containers in order to protect the products during land, air, and sea transportation. Several different grades of packaging can be offered depending on the mode of transport and the expected storage conditions. The packaging options that we offer are
    1) standard grade/prefabricated packing
    2) economical grade/cardboard carton
    3) best grade/closed wooden crate

    Since the user best knows their crate requirements, they should select the option that is most suited to their needs and include that information in the purchasing specification. Special packaging arrangements can be accommodated upon request.

2. Each container is marked with the number of insulators it contains, the catalog number, the manufacturer's name, and any other customer requests.
3. Each packing (wooden Cases or Paper ubes) attached specification and certification of products.

Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv

 

Exihibition
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv

We have been participating in various exhibitions at home and abroad from 2010 to 2020. At the exhibition, relevant people from the industry and us saw our products directly and closely.

FAQ

1. Q: Are you the factory or trading company?
A: We are factory who was founded in 2008. We also source all the items for the clients.

2. Q: What're your main products?
A: insulators, the hardware of all kinds for high-voltage applications and related products.
 

3. Q: Can I get some samples?
A: Yes, sample order is available for quality check and market test.
 

4. Q: What's your payment terms?
A: We usually accept :Payment Term: 30% T/T after order confirmed, balance 70% before shipment. L/C is also available.
 

5. Q: How can you control your quality? 
A: For each production processing, we have a complete QC system for the chemical composition, physical and electrical properties. After production, all the goods will be tested according to related standards, and the ex-factory test reports will be sent along with shipment documents.
   

6. Q: Does your company accept customization?
A: We accept OEM service.
 
7. Q: What's your warranty terms?
A: We offer 24 months warranty terms.
 
8. Q: Do you have the products in stock?
A: Depends on your request, we have standard models in stock. Some special product and big order will be newly produced according to your order.
 
9. Q: What do you have for the certificate?
A: ISO9001, ISO14001, ISO45001, Type test etc.
 
10. Q: How to become the agents for Line?
A: We welcome you to be Line's agent. 
We will depend on the sales turn over and also do research on your market. If you have interest, let us discuss more!
 
11.Q: Can we visit your company?
A: Yes, for sure, you are welcome to visit our company.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv pictures & photos
Composite Line Station Post Insulator for Power Transmission 11kv 33kv 69kv 110kv
US $5-250 / Piece
Min. Order: 5 Pieces
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
102
Year of Establishment
2008-07-03