Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | AC Drive |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Link of Transformation: | AC-DC-AC Variable-Frequency Drive |
Customization: |
---|
Suppliers with verified business licenses
Item | Specifications | ||
Basic functions | Control system | Direct torque control driver. | |
Compatible motor |
High efficiency drive induction motor and synchronous motor. |
||
Maximum frequency | SVC control: 0~500Hz; V/F control: 0~1000Hz. |
||
Carrier frequency | 2kHz~16kHz; Depending on load, can automatically adjust. | ||
Input resolution | Digital: 1 RPM; | Analog:0.025% of the maximum rotation speed. | |
Control modes | direct torque control; Open vector control (SVC). |
||
Starting torque | 150% @ 0.25Hz @ Open Loop(SVC) ; 200% @ 0Hz @ Close Loop(FVC). |
||
Speed range | 1:200 @ Open Loop(SVC). | 1:3000 @ Close Loop(FVC). | |
Speed accuracy | ±0.5% @ Open Loop(SVC). | ±0.01% @ Close Loop(FVC). | |
Torque accuracy | ±5% (FVC) | ||
Overload capacity |
Heavy-duty application: 150% rated current 60s @ 40°C. In other cases, the duration depends on the temperature of transmission. |
||
Torque boost | Automatic | Manual 0.1%~30.0% | |
V/F curve | Intelligent adaptation. | ||
V/F separation | Two types:Full separation, half separation. | ||
Ramp mode |
Straight line or S curve acceleration and deceleration modeTwo kinds of acceleration time, acceleration and deceleration time range 0.0s-650.00s. |
||
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-36.0s Braking action current value: 0.0%-100.0% |
||
JOG control | JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
||
Simple PLC | Up to 16 speeds via the simple PLC function or DI terminals | ||
Onboard PID | Process-controlled closed loop control system | ||
Auto voltage regulation (AVR) |
Keep constant output voltage automatically when grid voltage fluctuates. | ||
Overvoltage/ Overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/overcurrent. | ||
Fast current limit function | Protect inverter from overcurrent malfunctions. | ||
Power DIP ride through |
The regenerative energy from load compensates the voltage reduction so that the inverter can continue to run for a short time. | ||
Personalization features |
Instantaneous stop constantly |
The drive can be maintained for a short period of time (in the case of instantaneous power failure, the voltage reduction is compensated by load feedback energy), the sustainable time depends on the mechanical inertia of the load at the moment. | |
Torque limit and control |
Automatic torque limitation during operation (to prevent frequent overcurrent failures due to excessive torque). | ||
Defensive function | Output short circuit protection, input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection, brake chopper overload, brake chopper short circuit, brake resistance overload protection and other protection functions. | ||
Timed control |
Timing control function: Set the time range from 0.0min to 6500.0Min. |
||
Bus communication | Built-in Modbus/CANopen communication is standard. | ||
Intelligent temperature control | With full coverage system temperature detection, intelligent real-time IGBT chip temperature monitoring, and with the change of transmission temperature carrier and current intelligent optimization adjustment. | ||
Powerful background software | Support differential encoder, collector open encoder, UVW encoder, rotary transformer encoder, sines and cosines encoder. | ||
Operations | Command source | Control keyboard input, control terminal input, bus communication input, and other input modes can be switched to each other. | |
Frequency source | Digital given, analog voltage (flow) given, pulse given, bus communication given, PID given and so on, the given mode can be switched to each other. | ||
Auxiliary frequency source |
Six auxiliary frequency sources.The auxiliary frequency fine tuning and frequency synthesis can be realized flexibly. | ||
Input terminal |
The following is the standard configuration: |
||
Output terminal |
The following is the standard configuration: |
||
Display and panel | Human-computer interaction interface |
Intelligent sealed LCD control keyboard. |
|
Parameters of the copy |
Fast copy and copy of parameters can be achieved by LCD control keyboard. |
||
Environment | Location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. | |
Altitude | Less than 1000m. | ||
Ambient temperature |
-10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C) | ||
Humidity | Less than 90%RH, without condensing | ||
Vibration | Less than 5.8m/s2 (0.6g). | ||
Storage temperature |
-20ºC~+60ºC. |
Inverter model | Dimensions(mm) | Holes(mm) | Net(Kg) | ||||
H700-0004T4G | H | W | D | W1 | H1 | ||
186 | 126 | 170 | 115 | 175 | φ4 | 2 |