Mounting: | Wall-Mounted |
---|---|
AC Supply System: | AC380V |
Input Frequency: | 45-65Hz |
IP Ratings: | IP 54 |
Cooling: | Air-Cooled |
Type of Each Output: | DC200-750V |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
NO. | Parameters | Requirements |
General Requirements | ||
1 | EV Charger Type | DC |
2 | Charger Capacity | 20KW |
3 | Product Model NO. | ENC-DCB030A |
4 | Mounting | Wall-mounted |
Input Requirements | ||
5 | AC Supply System | Three-Phase, 5 Wire AC system |
6 | Nominal Input Voltage | AC380V±15% |
7 | Input Frequency | 45-65Hz |
8 | Cable length | 4m |
Environmental Requirements | ||
9 | Ambient Temperature Range | -25 to 55°C |
10 | Ambient Humidity | 5 to 95% |
11 | Storage Temperature | -40 to 70°C |
Mechanical Requirements | ||
12 | IP Ratings | IP 54 |
13 | Cooling | Air-cooled |
Output Requirements | ||
14 | Number of Outputs | 1 |
15 | Type of Each Output | DC200-750V |
16 | Single Output Max. Current | 80 Amp |
17 | Power Factor | ≥0.99 ( 50% load above ) |
User Interface & Display Requirements | ||
18 | Display & Touch-Screen Size | 7 InchesTouch Screen |
19 | User Authentication | QR Code / RFID Card / Password Login |
20 | Metering Information | Consumption Units |
Communication Requirements | ||
21 | Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) |
22 | Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) |
Protection & Safety Requirements | ||
23 | Executive Standard | IEC 62196 2017, IEC 61851 2017 |
24 | Safety Parameters | Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |
Suppliers with verified business licenses