• Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
  • Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
  • Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
  • Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
  • Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
  • Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine

Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine

Classification: Ophthalmic Equipment
Type: Oct Machine
Certification: CE
Oct Imaging Methodology: Spectral Domain Oct
Optical Source: Super Luminescent Diode(Sld), 840mm
Scan Speed: 36, 000 a-Scan/S
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Chongqing, China
Experienced Team
The supplier has 18 foreign trading staff(s) and 12 staff(s) with over 6 years of overseas trading experience
OEM Services
The supplier provides OEM services for popular brands
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (15)

Basic Info.

Model NO.
OSE-3000 OCT Machine
Axial Resolution(Optical)
5 Microns(Optical), 2.7 Microns(Digital)
Tranverse Resolution
15 Microns(Optical), 3 Microns(Digital)
a Scan Depeth
2.3mm
Diopter Range
-20 to +20 Diopters
Fundus Imaging Methodology
Line Scanning Ophthalmoscopy(Lso)
Frame Rate
10 Fps
Minimum Pupil Diameter
3.0mm
Transport Package
Standard Exporting Packaging
Trademark
VSO
Origin
Chongqing, China
Production Capacity
1000 Units/Month

Product Description

CE Approved OSE-3000 Ophthalmic OCT Machine Price

Features:
MACULA
1. LSO:Equipped with LSO(Line Scanning Ophthalmoscopy)OSE-3000 provides simultaneously high quality fundus imaging,which is easy for physicians to localize the lesion. 
2. MACULA:Macula HD line:High definition OCT imaging reveals small lesions,OCT scan length can be switched between 6mm and 12mm.
3. Macula Six-line Radial:Having a glimpse of the retina with HD imaging and quick data analysis Software Analysis:Retinal thickness analysis,Ganglion cell analysis,High definition OCT imaging with 5 images averaging. 
4. Macula Cube:A point-by-point assessment of retinal thickness with a 500x100 dense cube Software Analysis:Retinal thickness analysis,Progression analysis,3D view,En-face analysis.
GLAUCOMA
1. For comprehensive glaucomaanalysis.OSE-3000 offers two scan modes:glaucoma cube scan in macular area and glaucoma cube scan in disc area.Evenly distributed sampling rate with 200x200 A-scans provides reliable information for early glaucoma detection and management.
2. Glaucoma(Macular):Software Analysis:Ganglion cell analysis,Progression analysis.
3. Glaucoma(Disc):Software Analysis:RNFL analysis,Cup-disk analysis,Calculation circle and circle scan tomogram,Progressionanalysis,OU comparative analysis.
4. Informative Report:OU comparative analysis,Progression analysis report.
ANTERIOR SEGMENT
1. Anterior HD line:High-definition OCT imaging of the cornea enables localization of the Bowman's layer, the interface between corneal stroma and and epithelium, Anterior Chamber Angle,Manual measurement is available.
2. Anterior Six-line Radial:The anterior segment scanning through 6 radial lines of equal length can be used to measure the central corneal thickness, Software Analysis, Corneal pachymetry,Manual measurement.
PERMIUM FUNCTIONS
1. En-face Analysis:En-face OCT provides ability to precisely localize lesions within specific  subretinal layers.
Choroid View
IS/OS-Ellipsoid View
Mid-Retina View
VRI View
3D En-face View
2. Network System: Remote Analysis System:Moptim provides a remote viewer software for displaying,enhancing,analyzing and saving digital images obtained with MOcaen 3000/3000plus.
Remote Diagnosis System: Customer scan are reviewed remotely by specialists at Big Picture Eye Health for over 45 eye pathologies.
The software immediately generates a customer report, including educational content and specialist referral if needed.
This optional module,which is developed and operated by Big picture Eye Health, can be connected to OSE-3000 seamlessly.
Ce Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct MachineCe Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
Specifications:
OCT Imaging
Methodology Spectral Domain OCT
Optical Source Super Luminescent Diode(SLD), 840mm
Scan Speed 36,000 A-Scan/s
Axial Resolution(Optical) 5 Microns(Optical), 2.7 Microns(Digital)
Tranverse Resolution 15 Microns(Optical), 3 Microns(Digital)
A Scan Depeth 2.3mm
Diopter Range -20 to +20 Diopters
Scan Patterns Macular: HD Line Scan(6mm-12mm), 3D Scan(6mmx6mm), 6-Line Radial Scan
Disc: 3D Scan(6mmx6mm)
Anterior: HD Line Scan(6mm), 6-Line Radial Scan
Fundus Imaging
Methodology Line Scanning Ophthalmoscopy(LSO)
Frame Rate 10 FPS
Minimum Pupil Diameter 3.0mm
Field of View 47 Degrees
Electrical and Physical
Weight 29kg
Dimension 450mm(L)x250mm(W)x450mm(H)
Source Voltage AC100V-240V
Frequency 50Hz-60Hz
Power 90VA

Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine
Ce Approved Cheap Price Ose-3000 Ophthalmic Oct Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 13485