Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC

Type: Bare
Conductor Type: Stranded
Application: Overhead
Conductor Material: Aluminum Alloy
Sheath Material: None
Insulation Material: Bare
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory
Diamond Member Since 2022

Suppliers with verified business licenses

Henan, China
  • Overview
  • Product Description
  • Product Parameters
  • Testing
  • Certifications
  • Packaging & Shipping
  • Customer Visit
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
AAAC Conductor
Material Shape
Round Wire
Range of Application
Overhead
Certification
ISO9001, CE, SGS TUV
Brand
Ume
Third Party Inspection
Accepted
Sample
Free
Color
Customer Specified
OEM
Accepted
Transport Package
Drum
Specification
up to 1439MCM
Trademark
UME
Origin
China
HS Code
7614900000
Production Capacity
500, 000km Per Month

Product Description

 
Product Description

ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.


 

Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC
Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC





1. Applications
AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coastlines where there can be a problem of corrosion in the steel of an ACSR construction.

2. Construction
AAAC is concentric-lay- stranded, similar in construction and appearance with1350 grade aluminum conductors.They were developed to the need of economical conductor for overhead applications requiring higher strength than that of 1350 grade aluminum conductors, but without a steel core.

3. Standards 
BS EN 50182, IEC 61089, DIN 48201, ASTM B399

Product Parameters

BS EN 50182

Code
Name
Nominal
Area
No. / Dia. of Wire Approx. Overall
Dia.
 Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C 
mm2 No./mm mm kg/km kN Ω/km
Box 18.8  7/1.85 5.55  51.4  5.6  1.7480 
Acacia 23.8  7/2.08 6.24  64.9  7.0  1.3828 
Almond 30.1  7/2.34 7.02  82.2  8.9  1.0926 
Cedar 35.5  7/2.54 7.62  96.8  10.5  0.9273 
Deodar 42.2  7/2.77 8.31  115.2  12.4  0.7797 
Fir 47.8  7/2.95 8.85  130.6  14.1  0.6875 
Hazel 59.9  7/3.30 9.90  163.4  17.7  0.5494 
Pine 71.6  7/3.61 10.83  195.6  21.1  0.4591 
Holly 84.1  7/3.91 11.73  229.5  24.8  0.3913 
Willow 89.7  7/4.04 12.12  245.0  26.5  0.3665 
Oak 118.9  7/4.65 13.95  324.5  35.1  0.2767 
Mulberry 150.9  19/3.18 15.90  414.3  44.5  0.2192 
Ash 180.7  19/3.48 17.40  496.1  53.3  0.1830 
Elm 211.0  19/3.76 18.80  579.2  62.2  0.1568 
Poplar 239.4  37/2.87 20.09  659.4  70.6  0.1387 
Sycamore 303.2  37/3.23 22.61  835.2  89.4  0.1095 
Upas 362.1  37/3.53 24.71  997.5  106.8  0.0917 
Yew 479.0  37/4.06 28.42  1319.6  141.3  0.0693 
Totara 498.1  37/4.14 28.98  1372.1  146.9  0.0666 
Rubus 586.9  61/3.50 31.50  1622.0  173.1  0.0567 
Sorbus 659.4  61/3.71 33.39  1822.5  194.5  0.0505 
Araucaria 821.1  61/4.14 37.26  2269.4  242.2  0.0406 
Redwood 996.2  61/4.56 41.04  2753.2  293.9  0.0334 

IEC 61089

Code
Name
Nominal
Area
No. / Dia. of Wire  Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C 
mm2 No./mm mm kg/km kN Ω/km
16 18.4 7/1.83 5.49  50.4  5.4  1.7896
25 28.8 7/2.29 6.87  78.7  8.5  1.1453
40 46 7/2.89 8.67  125.9  13.6  0.7158
63 72.5 7/3.63 10.89  198.3  21.4  0.4545
100 115 19/2.78 13.90  316.3  34.0  0.2877
125 144 19/3.10 15.50  395.4  42.4  0.2302
160 184 19/3.51 17.55  506.1  54.3  0.1798
200 230 19/3.93 19.65  632.7  67.9  0.1439
250 288 19/4.39 21.95  790.8  84.9  0.1151
315 363 37/3.53 24.71  998.9  107.0  0.0916
400 460 37/3.98 27.86  1268.4  135.8  0.0721
450 518 37/4.22 29.54  1426.9  152.8  0.0641
500 575 37/4.45 31.15  1585.5  169.8  0.0577
560 645 61/3.67 33.03  1778.4  190.1  0.0516
630 725 61/3.89 35.01  2000.7  213.9  0.0458
710 817 61/4.13 37.17  2254.8  241.1  0.0407
800 921 61/4.38 39.42  2540.6  271.6  0.0361
900 1036 91/3.81 41.91  2861.1  305.6  0.0321
1000 1151 91/4.01 44.11  3179.0  339.5  0.0289
1120 1289 91/4.25 46.75  3560.5  380.3  0.0258
1250 1439 91/4.49 49.39  3973.7  424.4  0.0231

DIN 48201

Nominal
Area
Actual
Area
No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
Load
Max. DC Resistance
at 20° C
mm2 mm2 No./mm mm kg/km kN Ω/km
16 15.9  7/1.70 5.1  43 4.4  2.0742 
25 24.3  7/2.10 6.3  66 6.8  1.3593 
35 34.4  7/2.50 7.5  94 9.6  0.9591 
50 49.5  7/3.00 9.0  135 13.8  0.6660 
50 48.4  19/1.80 9.0  133 13.5  0.6849 
70 65.8  19/2.10 10.5  181 18.4  0.5032 
95 93.3  19/2.50 12.5  256 26.1  0.3551 
120 117.0  19/2.80 14.0  322 32.7  0.2831 
150 147.1  37/2.25 15.8  406 41.1  0.2256 
185 181.6  37/2.50 17.5  500 50.7  0.1828 
240 242.5  61/2.25 20.3  670 67.7  0.1371 
300 299.4  61/2.50 22.5  827 83.6  0.1110 
400 400.1  61/2.89 26.0  1104 111.8  0.0831 
500 499.8  61/3.23 29.1  1379 139.6  0.0665 
625 626.2  91/2.96 32.6  1732 174.9  0.0531 
800 802.1  91/3.35 36.9  2218 224.0  0.0415 
1000 999.7  91/3.74 41.1  2767 279.2  0.0333 

ASTM B399

Code
Name
Total Area 1350 Grade Equivalent  No. / Dia. of Wire Approx. Overall
Dia.
Approx.
Weight
Calculated Breaking
 Load
Max. DC Resistance
at 20° C
AWG or MCM mm2 AWG or MCM No./mm mm kg/km kN Ω/km
Akron 30.6 15.5  6 7/1.68 5.04  43 4.9  2.1588
Alton 48.7 24.7  4 7/2.12 6.36  68 7.8  1.3557
Ames 77.5 39.2  2 7/2.67 8.01  108 12.4  0.8547
Azusa 123.3 62.4  1 7/3.37 10.11  171 18.9  0.5365
Anaheim 155.4 78.6  2/0 7/3.78 11.34  216 23.8  0.4264
Amherst 195.7 99.3  3/0 7/4.25 12.75  272 30.0  0.3373
Alliance 246.9 125.1  4/0 7/4.77 14.31  343 37.8  0.2678
Butte 312.8 158.6  266.8 19/3.26 16.30  435 46.5  0.2112
Canton 394.5 199.9  336.4 19/3.66 18.30  548 58.6  0.1676
Cairo 465.4 236.4  397.5 19/3.98 19.90  649 69.3  0.1417
Darien 559.5 283.6  477 19/4.36 21.80  778 83.1  0.1181
Elgin 652.6 331.0  556.5 19/4.71 23.55  908 97.0  0.1012
Flint 740.8 374.5  636 19/3.59 25.13  1028 107.4  0.0894
Greeley 927.2 469.6  795 19/4.02 28.14  1289 134.6  0.0713
Testing

HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!

 

     Production:

  • Raw material inspection and test
  • Production process test
  • Unqualified product control
  • Regular test and examination
  • Finished product inspection
Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC

 

Certifications
UME CABLE has completed several third-party product certifications to ensure our customers that all of the wire and cable purchased and installed in your projects, will fully and consistently meet all criteria of the required production and performance standards, also you are guaranteed we (as the manufacturer) and the products supplied are both valid and continuously monitored by those globally recognized quality verification system listed as below: ISO9001, ISO14001, ISO45001, CE, SGS, TUV.
Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC


 

Packaging & Shipping

 

Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC
Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC


 
Customer Visit

Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC

 
Company Profile
Bare Conductor Transmission Line All Aluminum Alloy Conductor AAAC
UME CABLE is one of the leading companies in the production and distribution of cables and wires in China. As a manufacturer, we have supplied quality products to more than 50 countries. Our mission is to offer our customers the best quality cable and wire products at the most competitive price, to extend and zoom the business success of our partners, to make power reach where it is needed, to optimize the running utility grids, and ultimately, to power the world. Our version is to be the most customer-centric cable and wire company with our solid technology, enthusiastic services, and robust products.

UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.

 

FAQ

Q1: Are you a manufacturer?
Yes, we are the manufacturer.

Q2: What are your main products?
  Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.                                                                                                       
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s' Conductor.

Q3: Do you provide samples? Is it free or extra?
  Yes, we could offer the samples for free

Q4: Is the quality of your products guaranteed?
  We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.

Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.

Q6: What is your payment term?
  T/T or L/C

Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001