• Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
  • Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
  • Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
  • Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
  • Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester
  • Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

After-sales Service: Online
Warranty: 1 Year
Type: Porosity Tester
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Samples:
US$ 3000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
LR-WBL-810
Display
Digital
Control
Manual Control
Weight
75kg
Power Source
AC220V
Aperture Analysis Range
3.5 to 5000
P/P0 Range
1 X 10-6-0.995
Vacuum Pump
Mechanical Pump
Limiting Vacuum Degree
1.0 X 10-4 Torr
Adsorption Gas
Nitrogen
Transport Package
Plywood Cases
Specification
70*70*80cm
Trademark
LONROY
Origin
Guangdong
HS Code
9024800000
Production Capacity
200

Product Description

Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Product Description:

The analyzer refers to ISO9277, ISO15901 and GB-119587 standards, according to the principle of static volumetric measurement, through the mass balance equation, static gas balance and pressure measurement to test the desorption process, the test process is carried out at the temperature of liquid nitrogen. When a known amount of gas is filled into the sample tube, the pressure will drop, and the molar mass of the adsorbed gas at adsorption equilibrium is calculated. The BET surface area and Langmuir specific surface area of single and multi-point samples were calculated by using the theoretical model. The distribution of pore volume, area and total pore volume in BJH; T -- plot micropore volume and surface area, Dubinin-Astakhov micropore distribution, Horvath -- Kawazoe micropore distribution; Density function theory (DFT) and Monte Carlo (MC) aperture distribution model, etc.

 

 

Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Product Features

1. Modular air path design: the introduction of the design concept, the use of modular stainless steel real air path design and anti-leakage measures, so as to ensure the realization of high vacuum, avoid the abuse of too much easy leakage due to the connection of pipeline joints.

2.Constant temperature: Because of its internal structure design, the self-developed metal dewar can store liquid nitrogen for more than ten days, and there is almost no loss of liquid nitrogen during the experiment, so as to ensure the constant temperature of the tested sample, and avoid the defects of fragile and unmovable glass dewar.

3.Sensors: multiple sensors and 22 bit AD conversion devices, to ensure the precision of the surface area and aperture calculation.

4.Its density function theory (DFT) and Monte Carlo (MC) pore size distribution model have established the leading position in the specific surface area and porosity analyzer industry in China, and are also at a high level in the world.

5. Operation automation: the process of adsorption and desorption is controlled by computer without manual operation.

 

 Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Technical Features

1. BET surface area of single point and multi-point, Langmuir specific surface area

2. Volume and area distribution of pore and macropore in BJH, total pore volume

3,.T-plot micropore volume and surface area, Dubinin-Astakhov micropore distribution, Horvath -- Kawazoe micropore distribution

4. Density function theory (DFT) and Monte Carlo (MC) aperture distribution model

[Output report]

Direct print and EXCEL output of adsorption and desorption isotherms, BET surface area, Langmuir surface area, T-plot micropore volume, BJH pore volume, pore area, total pore volume, total pore area, DBinin-Astakhov, Horvath-KawaZoe micropore distribution, NLDFT/GCMC pore distribution, Review report.

[ Scope of Application ]

Research AND PRODUCT TESTING OF VARIOUS materials, including measurement of ZEolite, MOLECULAR sieve, silica, alumina, soil, clay, catalyst, organomeTALlic compound skeleton structure and other materials.

 

 Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Technical parameters

 

WBL-810

WBL-820

WBL-830

Specific surface area

0.01m2/g to no upper limit

0.01m2/g to no upper limit

0.01m2/g to no upper limit

Aperture analysis range

3.5 to 5000

3.5 to 5000

3.5 to 5000

Test principle

Physical adsorption of nitrogen at Low temperature (Static capacity method)

Physical adsorption of nitrogen at Low temperature (Static capacity method)

Physical adsorption of nitrogen at Low temperature (Static capacity method)

Adsorption gas

nitrogen

nitrogen

nitrogen

P/P0 range

1 x 10-6-0.995

1 x 10-6-0.995

1 x 10-6-0.995

Pressure, Temperature measurement

Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1

Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1

Imported pressure sensor 0-133kpa, accuracy 0.12%, 3 temperature sensors: PT-100, accuracy 0.1ºC 1

 dewar

2L, duration 80 hours

2L, duration 80 hours

2L, duration 80 hours

Vacuum pump

Mechanical pump

Mechanical pump

Mechanical pump

Limiting vacuum degree

1.0 x 10-4 torr

1.0 x 10-4 torr

1.0 x 10-4 torr

Measuring software

Determination of adsorption/desorption isotherms

Determination of adsorption/desorption isotherms

Determination of adsorption/desorption isotherms

Physical parameters

700 X 700 X 800mm

700 X 700 X 800mm

700 X 700 X 800mm

Processing power

 

 At the same time, 1 sample was determined

The number of processed samples was 3

 

At the same time, 2 sample was determined

The number of processed samples was 3

 

At the same time, 3 sample was determined

The number of processed samples was 3

 

Aperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer TesterAperture Distribution Model Automatic Specific Surface Area and Porosity Analyzer Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now