After-sales Service: | 2 Years |
---|---|
Warranty: | 2 Years |
Display: | Digital |
Installation: | Indirect Connected |
Usage: | Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter |
Electric Equipment: | Three-phase Four-wire |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Meter type
|
Basic function
|
Optional function
|
AMC72-E4/KC
AMC72L-E4/KC
|
Three phase voltage, Zero sequence voltage
Three phase current, Zero sequence current
Three phase active power, Total active power Three phase reactive power, Total reactive power Three phase apparent power, Total apparent power Three phase Power factor, Total power factor Frequency, Voltage phase angle, Voltage and current imbalance, Forward and reverse power Four quadrant energy metering, System time display 1channel RS485 interface/Modbus-RTU protocol and the statute DLT645.
|
2DI+2DO+1Ep(K) 4DI+2DO(K)
Event record(SOE)
T2-31th and total harmonics measurement(H )
1 Channel analog output
|
AMC96-E3/KC AMC96L-E3/KC |
4DI+2DO+1Ep(K) 2DI+2DO+1Ep(K)
Eventrecord(SOE)
2-31th harmonic measurement (H)
2-channel analog output(M)
|
|
AMC96-E4/KC
AMC96L-E4/KC
|
||
AMC72-E/KC AMC72L-E/KC |
single-phase voltage,single-phase current active power,reactive power, apparent power Power factor Frequency Four quadrant energy metering, System time display 1channel RS485 interface/Modbus-RTU protocol and the statute DLT645.
|
DI+2DO+1Ep(K) 4DI+2DO(K)
Event record(SOE)
Total harmonic measurement(H)
1 Channel analog output
|
Technical parameters
|
Value
|
|||
Input
|
Connection
|
Single phase-2-wire,3-phase-3-wire,3-phase-4-wire
|
||
Frequency
|
45-65Hz
|
|||
Voltage
|
Rating:
single-phase:AC100V,400V
Three-phase:AC3×57.7V/100V(100V),3×220V/380V(400V),3×380V/660V(660V)(96sizeonly)
Note:72 profile not suitable for high voltage applications
|
|||
Overload:1.2 fold rating{continuous):2fold ratingfor 1 second
|
||||
Power consumption:<0.5VA
|
||||
Current
|
Rating:AC IA,5A
|
|||
Overload:1.2 fold rating(continuous);10 fold rating for 1second
|
||||
Power consumption:<0.5VA
|
||||
Output
|
Electric energy
|
Output mode:open-collect or photo-coupler pulse
|
||
Pulse constant:10000 imp/kWh(settable),see wiring diagram for details;
|
||||
Communication
|
RS485 port,Modbus-RTU protocol, DLT645 protocol (versions 07 and 97),baud rate1200~38400
|
|||
Function
|
Switching input
|
Dry contact input,built-in power supply;
|
||
Switching output
|
Output mode:Relay normally open contact output
|
|||
Contact capacity:AC250V/3A,DC30V/3A
|
||||
Analog output
|
1-5V,4-20mA
|
|||
Accuracy class
|
Frequency:0.05Hz,Current,Voltage:0.2class,Reactive power:l.0class,Reactive Electric energy:l.0class, active power:0.5class, active electric energy:0.5class,2-31th harmonic measurement:±1%
|
|||
Power supply
|
AC/DC85-265V
|
power consumption≤10VA
|
||
Security
|
Powerfrequencywithstandvoltage
|
Between Power supply// Switching Output// Current Input// voltage Input and Transmitting// Communication// Pulse Output// switching input AC2kV 1min;Between Power supply,switching output,Current Input,voltage Input AC2kV1min;Between Transmitting,Communication,Pulse Output,switching inputAC1kV1min;
|
||
Insulationresistance
|
Input,Output end to machine enclosure>100MΩ
|
|||
Environment
|
Temperature
|
work:-25°C~+65°C storage:-40°C~+80°C
|
||
Humidity
|
≤93%RH Non-condensing
|
|||
Altitude
|
≤2500m
|
Suppliers with verified business licenses