• Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
  • Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
  • Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
  • Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
  • Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
  • Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Warranty: 2 Years
Display: LCD Display
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment: DC Energy Meter
Theory: Static Meter
Samples:
US$ 103.60/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Shanghai, China
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 131 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (26)
  • Overview
  • Product Description
  • Application
  • Features
  • Product Parameters
  • Wiring Chart
  • Installation Instructions
  • Solution
  • Company Profile
Overview

Basic Info.

Model NO.
DJSF1352-RN
Power Meter Connection
Terminal
Measured Signal
Continuous Wave
Type
Energy Meter
Certification
RoHS, ISO, CE, UL1741;TUV
Customized
Customized
Communication
Modbus-RTU Dl/T 645-2007
Frequency
45~60Hz
Application
EV Charging Pile, Solar PV
Rated Voltage
0~1000V DC
Measurement
1-Circuits DC Voltage, Current, Power, Kwh
Power Consumption
≤3W
LCD Display
8-Bit Segment LCD Screen
Transport Package
Carton
Specification
DC meter
Trademark
Acrel
Origin
China

Product Description

 

DJSF1352-RN DC Dual-circuits Monitoring DIN Rail Energy Meter

Product Description
 Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

DJSF1352-RN rail-mounted DC power meter with double DC input channels, designed for telecommunications base stations, DC charging piles, solar photovoltaic, and other applications, this series of meters can measure the voltage, current, power and forward and reverse energy and so on in the DC system. For the actual use of the site, you can measure the total power, but also measure the energy within a specified period of time. The test results can be used for local display, but also with industrial control equipment, and computers to form a measurement and control system. The meter can have an infrared communication interface and RS-485 communication interface and supports Modbus-RTU protocol and DLT645-97 (07) protocol at the same time.

The meter can have a relay alarm output and digital input function; You can set the ratio, alarm, and communication through the meter panel keys according to different requirements. The meter can have event recording of the switch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data (645 protocol), and maximum and minimum value recording functions of voltage and current power.
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Measurement: kWh, kVarh, Power, Current, Voltage and etc
Current Rating: -/75mV (with Shunt); -/4~20mA (with Hall Sensor)
Voltage Rating: 0~1000V DC
Application: DC Battery; Charging Pile; Solar PV and etc
Communication: RS485 (MODBUS-RTU)
Display: LCD Display
Dimension: 72*71*87.8mm (L*W*H)
Installation: 35mm DIN Rail
Power Supply: 85~265V AC/DC; 24V(±10%) DC; 48V(±10%) DC
Standard&Certificate: CE
The second DC energy metering
DI/DO Function: 2-channel DI&2-channel DO
Application

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV MonitorAcrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Features

 

 
 
 
 
 
 
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Dual Independent DC Circuits Monitoring

 For Twin EV Charger&Battery

 Voltage Input: DC 0~1000V

 Current Input (by Shunt): 0~75mV

 Current Input (by Hall Sensor): 0~5V, 0~10V, 0~20mA, 4~20mA

Built-in Bipolar Power Source

 Power Supply for Hall Effect CT

 Range: DC -12V ~ DC +12V

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Optional Dual RS485 Communication

 Protocol: MODBUS-RTU

 1 RS485 (standard)

DO/DI Function

 2 DO (2A/30V DC; 2A/250V AC)

 2 DI (dry contact)

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

LCD Display

 Parameter Display

 Programming Interface

Keypads HMI for Programming

 Parameter Display Setting

 Communication

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

 
Product Parameters
Technical parameters
Index
Input
Nominal value
Voltage input range
Current input
DC0-1000V 
Shunt:0-75mV
Hall sensor:0-20mA,4-20mA,0-   5V,0-10V and so on.
Overload
1.2 times rated(continuous);2 times rated/1 second;
Power consumption
Voltage:≤0.2VA, Current:≤0.1VA
Accuracy class
class 1
Function
Display
8-bit segment LCD screen (LCD)
Communication Interface
RS485, infrared
Communication protocol
Modbus-RTU, DL/T 645-2007
Switch
Switch output
2 Relay outputs, 2A/30VDC or 2A/250VAC
Switch input
2 dry contact inputs
Pulse output
A second pulse output, an energy pulse output
See the SYS->PLUS display in the meter menu settings. For example, The meter displays 100, which is 100imp/kWH
Power Supply
Voltage range
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
Power consumption
≤ 3W
Power frequency withstands voltage
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch input 2kV/1min
Average barrier-free working hours
≥50000h
Environment
Temperature
Normal operating temperature: -25 °C ~ +55 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40ºC~+70ºC
Humidity
≤93%RH, no condensation, no corrosive gas
Altitude
≤2500m
 
Maximum power
999.9W
10000
imp/kWh
9.999kW
1000
imp/kWh
99.99kW
100
imp/kWh
999.9kW
10
imp/kWh
 
 
Wiring Chart

Wiring with 75mV Shunt
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Wiring with Hall Sensor 4-20mA or 0-5V
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
Installation Instructions
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

 

Solution
Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor
 
Company Profile

 

Acrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV MonitorAcrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV MonitorAcrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV MonitorAcrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV MonitorAcrel DIN Rail Mounted Shunt Input 2 Circuits DC Energy Electric Power Meter LCD Display for Charging Piles and Solar PV Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
291
Year of Establishment
2003-06-23