• ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers
  • ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers
  • ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers
  • ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers
  • ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers
  • ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers

ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers

After-sales Service: Online Service
Warranty: 1 Year
Type: Kinematic Viscosity Tester
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Load Way: Mechanical Load
Samples:
US$ 2600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-265H
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Na
Oil Viscometer
Kinematic Viscosity of Liquid Petroleum Products
Colored LCD Display
It Can Display Time and Test Results
Easy to Operate
Automatically Calculate The Viscosity
Temperature Range
Ambient to 100c
Temperature Control Accuracy
0.01c
Bath Capacity
20L
Timing Range
0.0s-9999.9s
Capillary Viscometer Tubes
4 Tubes
Stirring Motor
1200rpm
Application
Automatic Kinematic Viscometer
Feature
Intelligent
Transport Package
Packed in Container
Specification
640 Mm*570mm*870mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
10000 Sets/ Month

Product Description

GD-265H ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers


Viscosity of Lubricating Oil:
When the engine stops, the pressure in the lubrication system disappears and the oil flows back to the sump under the force of gravity. The longer it is parked, the more it flows back, the thinner the oil film remaining on each friction surface, and the greater the wear when the engine is cold started. Therefore, in the cold start stage, the rapid delivery of oil to the friction surface is one of the main measures to reduce engine wear. To achieve this effect, the oil is required to have good fluidity at both low and high temperatures. Winter oils are classified according to their low temperature apparent viscosity. There are six grades: 0W, 5W, 10W, 15W, 20W and 25W. The smaller the grade, the lower the viscosity of the oil, the better the fluidity, and the lower the applicable temperature. , the better the protection of the engine during cold start. Oils for non-winter use are classified according to their kinematic viscosity at 100°C, and there are five grades: 20, 30, 40, 50 and 60. The larger the grade, the higher the applicable temperature and the better the protection performance at high temperature.
The key feature of the model GD-265H Kinematic Viscometer: the kinematic viscometer can set the coefficient of the viscometer, automatically complete the signal sampling, parameter calculation, printing results, etc., the test time can be controlled freely, and improve the accuracy.


Introduction:
The Automatic Kinematic Viscometer adopts color liquid crystal display, which can display the test time and test results. Using a glass cylinder and an electric stirring device, the sample is clearly observed and the temperature in the bathtub is uniform. Through parameter setting, one test can be done alone, or two samples can be done at the same time, and the work efficiency is high. High temperature control accuracy. The Automatic Kinematic Viscometer can set the viscometer coefficient, automatically complete the signal sampling, parameter calculation, print results, etc., the test time can be freely controlled, and the accuracy can be improved at the same time.


Parameters:
1. Working power supply: AC(220±10%)V 50Hz
2. Power consumption of the whole machine: ≤1800W
3. Use temperature of water bath: room temperature ~ 100.00ºC
4. Water bath temperature control accuracy: ±0.01ºC
5. Water bath capacity: 20L
6. Timing range: 0.0s~9999.9s
7. Timing accuracy: 60min not more than ± 0.05%
8. Number of samples: Number of capillaries inserted at the same time: 4
9. Stirring motor: speed 1200r/min
10. Applicable environment: Temperature: 15ºC~35ºC, relative humidity 85%
11. Temperature sensor: industrial platinum resistance Pt100
12. Capillary viscometer: Pinkevitch viscometer, Cannon-Fenske Routine Viscometer,
Ubbelohde viscometer
13. Dimensions: 530mm×400mm×670mm
14. Net weight of the instrument: 42kg



Packing Details:
ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers

Our factory:
ASTM D445 Automatic Kinematic Viscometer with Capillary Viscometers

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters