• ASTM D240 Microcomputer Automatic Calorimeter
  • ASTM D240 Microcomputer Automatic Calorimeter
  • ASTM D240 Microcomputer Automatic Calorimeter
  • ASTM D240 Microcomputer Automatic Calorimeter
  • ASTM D240 Microcomputer Automatic Calorimeter
  • ASTM D240 Microcomputer Automatic Calorimeter

ASTM D240 Microcomputer Automatic Calorimeter

After-sales Service: 1 Year
Warranty: 1 Year
Heat Capacity: About 10500 J/K
Oxygen Bomb Capacity: 300ml
Oxygenation Pressure: 2.8~3.2 MPa
Pressure Resistance: Water Pressure 20MPa
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Rating: 5.0/5
Chongqing, China
100% Finished Products Inspection
The supplier inspects 100% of finished products.
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)

Basic Info.

Model NO.
TP-5000C
Weight
58 Kg
Dimensions
77*58*70cm
Temperature Range
0~60ºC
Response Time
< 4 S
Resolution
0.0001ºC
Linearity
<0.08% Per 5ºC Temperature Rise
Transport Package
Export Standard Wooden Case
Specification
77*58*70cm
Trademark
TOP
Origin
Chongqing
HS Code
9031809090
Production Capacity
100 Sets/Month

Product Description

 
TP-5000C Microcomputer Automatic Calorimeter
ASTM D240 Microcomputer Automatic Calorimeter

Features

1.It is mainly composed of thermostatic calorimeter system and single-chip microcomputer control system. It is a type of highly automated calorimeter that is automatically controlled by a single-chip microcomputer system, capable of data processing.
2.The instrument is mainly used for the determination of the calorific value of combustible materials such as coal, petroleum, chemical, food, wood, explosives, etc., and the corresponding high calorific value and low calorific value are calculated while measuring the calorific value of the cartridge.
3.It adopts advanced touch LCD screen. The overall installation method ensures the firmness of the touch screen.
4.It adopts infrared technology and CRT display material to make the touch screen more durable. The multi-layer composite film covering ensures the best color distortion degree, reflectivity and clarity. It has highly sensitive with high positioning accuracy. The wear resistance is as high as 90% in the infested area. The service life is up to 10 years.
5.It adopts English display, and can be directly operated without external computer.More than 1000 data can be stored and temperature rise curve can be displayed.
6.It adopts advanced single-chip system and fully automatic operation. All you need to do is to weigh, load and fill oxygen. The instrument can automatically finish water injection, stirring, ignition, results print out and drainage, etc.
7.It has reasonable structure, excellent production, reliable performance and low failure rate, accurate test result. It adopts unique cooling correction system to ensure long-term stability of the instrument performance.
8.It is controlled by microcomputer. Coal quality report can be provided.Human-computer interaction is available, which is easy to learn. The water injection and drainage is automatic, no need to adjust water temperature. All you need to do is to put the oxygen bomb into the cylinder. The instrument will complete all the test process automatically.
9.The structure is accurate, and the unique cooling correction system is adopted to ensure the long time stability of the performance.
10.The advanced electronic refrigeration process is completely immune to changes in ambient temperature, ensuring that the temperature difference between the inner and outer cylinders of the instrument meets the requirements of the national standard. Long time continuous work is available.
11.The vacuum inner cylinder is made of stainless steel. The mixing system adopts imported motors from Germany.
12.It has fast test speed, and the test period is ≤8min (fast method) ≤15min. The repeatability and reproducibility of the calorific value test is better than the requirements of national standard GB/T384 Petroleum Products Calorific Value Method, and GB/T213-2008 The Coal Calorific Value Test Method and ASTM D240
13.This product has excellent performance and reliability even in harsh environments.
14.It has highly automatic. It can complete the whole test process by automatically using the amount of water in the built-in fixed container and automatically control the temperature difference between the inner and outer barrels.
15. It has rich data processing function. The historical test data, current day data and parallel sample data, etc. can be easily queried.

Technical Parameters
 
Heat capacity about 10500 J/K
 
Standard ASTM D240
Oxygen bomb capacity 300ml
Oxygenation pressure 2.8~3.2 MPa
 
Pressure resistance water pressure 20MPa
 
Weight 58 Kg
Dimensions 77*58*70cm
Temperature range 0~60ºC
 
Response time < 4 S
Resolution 0.0001ºC
Linearity <0.08% per 5ºC temperature rise
Temperature measurement error ±0.003ºC per 5ºC temperature accuracy range
 
Voltage AC220V ± 10%
Humidity ≤80%
 
Power consumption 30W
Temperature measurement error ±0.003ºC per 5ºC temperature accuracy range
 
Ignition time 5S
Heat capacity about 10500 J/K
 
Standard ASTM D240
Oxygen bomb capacity 300ml
Oxygenation pressure 2.8~3.2 MPa
 
Pressure resistance water pressure 20MPa
 
Weight 58 Kg
Dimensions 77*58*70cm
Temperature range 0~60ºC
 
Response time < 4 S
Resolution 0.0001ºC
Linearity <0.08% per 5ºC temperature rise
Temperature measurement error ±0.003ºC per 5ºC temperature accuracy range
 
Voltage AC220V ± 10%
Humidity ≤80%
 
Power consumption 30W
Temperature measurement error ±0.003ºC per 5ºC temperature accuracy range
 
Ignition time 5S


Contact  Me  : 
ASTM D240 Microcomputer Automatic Calorimeter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now