• 63A 2p 500V 6ka 10ka PV DC MCB for Solar System
  • 63A 2p 500V 6ka 10ka PV DC MCB for Solar System
  • 63A 2p 500V 6ka 10ka PV DC MCB for Solar System
  • 63A 2p 500V 6ka 10ka PV DC MCB for Solar System
  • 63A 2p 500V 6ka 10ka PV DC MCB for Solar System
  • 63A 2p 500V 6ka 10ka PV DC MCB for Solar System

63A 2p 500V 6ka 10ka PV DC MCB for Solar System

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Samples:
US$ 3/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
63A 2p 500V 6ka 10ka PV DC MCB for Solar System pictures & photos
63A 2p 500V 6ka 10ka PV DC MCB for Solar System
US $1.12-4.2 / Piece
Min. Order: 1 Piece

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
EDB1-63
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
Solar Arrester Surge Protector
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
VDE, ISO9001-2000, CE, CB, CCC, SAA
Voltage Ui
500V AC
ICU
10ka
Rated Current
10A,16A, 20A, 25A, 32A,40A, 50A, 63A
Ingress Protection
IP40; Wiring Port IP20
Vibration
Acc. to IEC60068-2-6
Dimension
Width:18mm/Pole High: 68mm Depth: 81mm
Transport Package
by Sea/Air
Specification
box
Trademark
Aswich
Origin
China
HS Code
853650
Production Capacity
1000000PC/Year

Packaging & Delivery

Package Size
9.00cm * 9.50cm * 10.00cm
Package Gross Weight
0.210kg

Product Description

Solar PV Circuit Breaker DC1000V DC500V DC800V DC MCB 6A to 63A are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protection is already protection or not required. Devices are designed for direct current (DC) control circuit applications in Solar PV Systems.

Technical Data

Pole 1P 2P 3P 4P
Rated Working Voltage Normal Voltage Ue 250V DC 500V DC 750V DC 1000V DC
High Voltage         Ue 300V DC 600V DC 900V DC 1200V DC
Frame Current 63A
Rated Current                                                                             In 10A,16A, 20A, 25A, 32A,40A, 50A, 63A
Rated Insulation Voltage                                                              Ui 1200V
Rated Impulse Withstand Voltage                                            Uimp 6kV
Tripping Characteristics B/C
Tripping Type Thermal Magnetic
Rated Ultimate Short-Circuit Breaking Capacity                             Icu 6/10kA
Rated Service Short-Circuit Interrupting Capacity                           Ics 6/7.5 kA
Electrical Life Actual 2000 Cycles
Standard 1500 Cycles
Mechanical Life Actual 20000 Cycles
Standard 8500 Cycles
Overvoltage Category III
Pollution Degree 3
Ingress Protection IP40; Wiring port IP20
Resistance to humidity and heat Class 2
Relative Humidity ≤ 95 %
Vibration acc. to IEC60068-2-6
Shocks acc. to IEC60068-2-27
Terminal capacity 2.5-25mm²
Fastening Torque of Terminals 2.5 N.m
Ambient Temperature -30°C~70°C
Storage Temperature -40°C~85°C
Installation Method DIN
Elevation ≤2000m
Dimension Width:18mm/Pole
High: 68mm
Depth: 81mm
Weight                                                                                             125.3g 250.55g 375.9g 501.1g
Product Description

  • Advantages of DC Circuit Breaker MCB 1P,2P,3P,4P
    1. DC Circuit Breakeris for non-professional operation by those untrained, and no maintenance is required.
    2. Satisfying conditions and applications as mentioned above,MCB with "ON-OFF" indicating device is considered suitable for isolation function.
    3. Particular devices such as surge protective devices,surge arrester etc are recommended to install at upstream line to MCB as precaution against potential surge voltage and current occurring at its power input side.
    4. Appropriate tripping curve being chosen and properly installed, MCB trips and switches off its protected circuit in case of fault, and thus provides protection against electric shock.
    5. Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
    6. Protection against both overload and short circuit
    7. Contact position indication
    8. Applicable to terminal and pin/fork type Busbar connection
    9. Easy mounting onto 35mm DIN rail

Detailed Photos

63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System

63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System

About us


63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System63A 2p 500V 6ka 10ka PV DC MCB for Solar System


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
63A 2p 500V 6ka 10ka PV DC MCB for Solar System pictures & photos
63A 2p 500V 6ka 10ka PV DC MCB for Solar System
US $1.12-4.2 / Piece
Min. Order: 1 Piece

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Registered Capital
100000 RMB
Plant Area
>2000 square meters