After-sales Service: | Provide |
---|---|
Warranty: | 1 Year |
Product name: | Insulation Resistance Tester |
Function: | Insulation resistance test, AC and DC voltage test |
Rated voltage: | 50V;250V;500V;1000V;2500V;5000V |
Insulation resistance range: | 0.1MOhm~400GOhm |
Customization: |
---|
Suppliers with verified business licenses
Product introduction
The whole instrument is beautiful, with wide range, high precision, high resolution, convenient operation, convenient carrying, accurate and reliable, stable performance and strong anti-interference ability. Moreover, it has shockproof, dust-proof and moisture-proof structures. It is a commonly used and essential instrument for the installation and maintenance of telecommunications, electric power, meteorology, machine rooms, oil fields, electromechanical equipment, and industrial enterprise departments that use electricity as industrial power or energy. It is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment.
Technical Indicators
Function | Insulation resistance test, AC voltage test, DC voltage test |
Power Supply | DC 1.5V 6 LR14 dry batteries for continuous standby for more than 100 hours |
Rated voltage | 50V;250V;500V;1000V;2500V;5000V |
Insulation resistance range | 0.1MΩ~400GΩ |
Voltage range | AC/DC:0V~750V |
Output short-circuit current | ≥2mA |
Capacitive load | 1uF |
Shift | Turn the shift knob to select the corresponding gear |
Backlight | Controllable gray white backlight, suitable for use in dim fields |
Display mode | 4-bit super large LCD display, with obvious contrast |
Measurement indication | LED flashes and buzzer rings during measurement |
LCD size | 108mm*65mm |
Instrument size | Length* Width*Height:212mm*175mm*76mm |
Test line | High voltage rod test line: 1 red; Probe test line: 1 black; Crocodile clip test line: 1; Crocodile clip: 1 |
Measurement time | The single test time is 1min. During the test, the user can stop manually or automatically after 1min, and the measurement data is displayed on the screen. |
Battery voltage | The battery undervoltage symbol shows that when the battery voltage is low, it reminds you to replace the battery in time. |
Automatic discharge function | The symbol flashes when discharging. The discharge completion symbol goes out. |
Auto Power Off | Automatic shutdown after 15 minutes of startup |
Power waste | Standby: about 40mA (backlight off); Measurement: About 100mA (backlight off) |
Weight | Instrument:1230g (Including battery) |
Working temperature and humidity | -10ºC~40ºC;Below 80%rh |
Storage temperature and humidity | -20ºC~60ºC;Below 70%rh |
Suitable for safety regulations | IEC61010-1(CAT III 300V, CAT IV 150V, Pollution degree 2) |
Suppliers with verified business licenses