Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Single & Three Phase
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 101/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Model Selection
  • Janson Controls
Overview

Basic Info.

Model NO.
FC610
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Janson Controls
Certificate
ISO9001, CE
Control Mode
V/F
Input Voltage
220V/380V
Output Power
0.4~7.5kw
Output Frequency
0~600Hz
Used for
Water Pump
Transport Package
Cartons/ Piece
Specification
Input Voltage Range -15%~+20%
Trademark
FC
Origin
China
HS Code
8504409999
Production Capacity
10000PCS/ Month

Product Description

Product Description

50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump
50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump
 

Product Parameters

Electrical Specification
Input Voltage Single Phase/Three Phase 200~240V,  Three Phase 380~440V
Fluctuate no more than±10%
,Imbalance Rate <3%
Input Frequency 50/60Hz ± 5%
Output Voltage 0V~Input Voltage
10~60Hz
Performance
Overload Capacity 110% rated output current for 1 minute
Control Method V/F Control
Run Command Setting Method Operation panel setting, analog setting, communication setting
Speed Setting Method Digital setting, analog setting/pulse setting, communication setting
Protective function
Overvoltage Stall Bus voltage automatic control to prevent overvoltage fault
Automatic Current Limiting Protection Output current is automatically limited to prevent over-current faults
Overload Pre-Alarm & Alarm Overload Pre-warning and protection
Output Phase Loss Protection Output phase loss automatic detection and alarm function
Overvoltage & Overflow Stall Control Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping
Output Short-to-Ground Protection Effective protection function for output short circuit to ground
Output Phase-to-Phase Short Circuit Protection Output interphase short circuit effective protection function
Input & Output
External analog power supply +24V,load capacity 100mA
Analog Input AI1:Voltage 0~10V/0-20mA
AI2
:Voltage 0~10V/0-20mA
Digital Input DI1,DI2
Digital Output DO1
Relay output TA/TB/TC:Contact rating 250VAC/3A Or 30VDC/1A
MUDBUS Communication A+,B-
Operation Display
LED Display 4 digit LED digital tube
Output frequency, output current, current pressure, set pressure and fault code etc.
Indicator Light 4 status lights
Environmental characteristics
Working Temperature -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC
Storage Environment Temperature -40~+70ºC
Altitude Less than 1000 meters, derating is required for more than 1000 meters
Humidity Less than 95%RH, no condensation
Vibration resistance 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3)
Protection Degree IP54
Pollution Level Class 2 (dry, non-conductive dust pollution)
 

Model Selection

Item No. Adaptable Motor (kW) Input Current (A) Output Current (A) Rate Capacity (kVA) W
(mm)
H
(mm)
D
(mm)
W1
(mm)
H1
(mm)
Diameter
(mm)
GW
(kg)
3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC610-4T-2.2P 2.20 5.80 5.10 4.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-4T-4.0P 4.00 10.00 8.60 5.90 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-4T-5.5P 5.50 14.60 12.50 8.60 200.00 235.00 146.00 129.00 225.00 Ø4 3.85
FC610-4T-7.5P 7.50 20.50 17.50 12.00 200.00 235.00 146.00 129.00 225.00 Ø4 3.85
FC610-4T-11P 11.00 28.00 25.00 16.00 200.00 235.00 146.00 129.00 225.00 Ø4 4.00
1 Phase Input and 3 Phase Output  220V (-15%~+15% Tolerance)
FC610-2S-0.75P 0.75 8.20 4.00 1.50 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-2S-1.5P 1.50 14.00 7.00 3.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-2S-2.2P 2.20 23.00 9.60 4.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
 

Janson Controls

50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump50/60Hz 220/380V AC FC610 Series 2.2kw Frequency Inverter/Converter for Water Pump